📄 rfc2496.txt
字号:
e3Plcp(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 [9] dsx3SYNTRAN ANSI T1.107-1988 [9] dsx3CbitParity ANSI T1.107a-1990 [9a] dsx3ClearChannel ANSI T1.102-1987 [8] e3Framed CCITT G.751 [12] e3Plcp ETSI T/NA(91)18 [13]." ::= { dsx3ConfigEntry 5 } dsx3LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx3Other(1), dsx3B3ZS(2), e3HDB3(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx3B3ZS and e3HDB3 refer to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length." ::= { dsx3ConfigEntry 6 }Fowler, Ed. Standards Track [Page 19]RFC 2496 DS3/E3 MIB January 1999 dsx3SendCode OBJECT-TYPE SYNTAX INTEGER { dsx3SendNoCode(1), dsx3SendLineCode(2), dsx3SendPayloadCode(3), dsx3SendResetCode(4), dsx3SendDS1LoopCode(5), dsx3SendTestPattern(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 interfaces.) Setting this variable causes the interface to begin sending the code requested. The values mean: dsx3SendNoCode sending looped or normal data dsx3SendLineCode sending a request for a line loopback dsx3SendPayloadCode sending a request for a payload loopback (i.e., all DS1/E1s in a DS3/E3 frame) dsx3SendResetCode sending a loopback deactivation request dsx3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a DS3/E3 frame. The DS1/E1 is indicated in dsx3Ds1ForRemoteLoop. dsx3SendTestPattern sending a test pattern." ::= { dsx3ConfigEntry 7 } dsx3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose ofFowler, Ed. Standards Track [Page 20]RFC 2496 DS3/E3 MIB January 1999 facilitating troubleshooting." ::= { dsx3ConfigEntry 8 } dsx3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx3NoLoop(1), dsx3PayloadLoop(2), dsx3LineLoop(3), dsx3OtherLoop(4), dsx3InwardLoop(5), dsx3DualLoop(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the desired loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value. dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx3OtherLoop Loopbacks that are not defined here. dsx3InwardLoop The sent signal at this interface is looped back through the device. dsx3DualLoop Both dsx1LineLoop and dsx1InwardLoop will be active simultaneously." ::= { dsx3ConfigEntry 9 }Fowler, Ed. Standards Track [Page 21]RFC 2496 DS3/E3 MIB January 1999 dsx3LineStatus OBJECT-TYPE SYNTAX INTEGER (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm must be set if and only if no other flag is set. If the dsx3loopbackState bit is set, the loopback in effect can be determined from the dsx3loopbackConfig object. The various bit positions are: 1 dsx3NoAlarm No alarm present 2 dsx3RcvRAIFailure Receiving Yellow/Remote Alarm Indication 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote Alarm Indication 8 dsx3RcvAIS Receiving AIS failure state 16 dsx3XmitAIS Transmitting AIS 32 dsx3LOF Receiving LOF failure state 64 dsx3LOS Receiving LOS failure state 128 dsx3LoopbackState Looping the received signal 256 dsx3RcvTestCode Receiving a Test Pattern 512 dsx3OtherFailure any line status not defined here 1024 dsx3UnavailSigState Near End in Unavailable Signal State 2048 dsx3NetEquipOOS Carrier Equipment Out of Service" ::= { dsx3ConfigEntry 10 }dsx3TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. loopTiming indicates that the recovered receive clockFowler, Ed. Standards Track [Page 22]RFC 2496 DS3/E3 MIB January 1999 is used as the transmit clock. localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface. throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface." ::= { dsx3ConfigEntry 11 } dsx3InvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of intervals in the range from 0 to dsx3ValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations)." ::= { dsx3ConfigEntry 12 } dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 } dsx3LineStatusLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value." ::= { dsx3ConfigEntry 14 } dsx3LineStatusChangeTrapEnable OBJECT-TYPEFowler, Ed. Standards Track [Page 23]RFC 2496 DS3/E3 MIB January 1999 SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether dsx3LineStatusChange traps should be generated for this interface." DEFVAL { disabled } ::= { dsx3ConfigEntry 15 } dsx3LoopbackStatus OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks established by a manager and remotely from the far end. The dsx3LoopbackStatus is a bit map represented as a sum, therefore is can represent multiple loopbacks simultaneously. The various bit positions are: 1 dsx3NoLoopback 2 dsx3NearEndPayloadLoopback 4 dsx3NearEndLineLoopback 8 dsx3NearEndOtherLoopback 16 dsx3NearEndInwardLoopback 32 dsx3FarEndPayloadLoopback 64 dsx3FarEndLineLoopback" ::= { dsx3ConfigEntry 16 } dsx3Channelization OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledDs1(2), enabledDs2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicatesFowler, Ed. Standards Track [Page 24]RFC 2496 DS3/E3 MIB January 1999 that this is a DS3 channelized into DS1s. The value of enabledDs3 indicated that this is a DS3 channelized into DS2s. Setting this object will cause the creation or deletion of DS2 or DS1 entries in the ifTable. " ::= { dsx3ConfigEntry 17 } dsx3Ds1ForRemoteLoop OBJECT-TYPE SYNTAX INTEGER (0..29)
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -