📄 rfc1694.txt
字号:
::= { sipDS3PLCPTable 1 } SipDS3PLCPEntry ::= SEQUENCE { sipDS3PLCPIndex IfIndex, sipDS3PLCPSEFSs Counter32, sipDS3PLCPAlarmState INTEGER, sipDS3PLCPUASs Counter32 } sipDS3PLCPIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the interface for which this entry contains management information. " ::= { sipDS3PLCPEntry 1 }Brown & Tesink [Page 19]RFC 1694 SMDS Interface Objects August 1994 sipDS3PLCPSEFSs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A DS3 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected." ::= { sipDS3PLCPEntry 2 } sipDS3PLCPAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm (1), receivedFarEndAlarm (2), incomingLOF (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if there is an alarm present for the DS3 PLCP. The value receivedFarEndAlarm means that the DS3 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS3 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states." ::= { sipDS3PLCPEntry 3 } sipDS3PLCPUASs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP." ::= { sipDS3PLCPEntry 4 } -- The SMDS Applications group -- Applications that have been identified for this group are:Brown & Tesink [Page 20]RFC 1694 SMDS Interface Objects August 1994 -- * IP-over-SMDS (details are specified in RFC 1209) smdsApplications OBJECT IDENTIFIER ::= { sip 4 } ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 } -- Although the objects in this group are read-only, at the -- agent's discretion they may be made read-write so that the -- management station, when appropriately authorized, may -- change the addressing information related to the -- configuration of a logical IP subnetwork implemented on -- top of SMDS. -- This table is necessary to support RFC1209 (IP-over-SMDS) -- and gives information on the Group Addresses and ARP -- Addresses used in the Logical IP subnetwork. -- One SMDS address may be associated with multiple IP -- addresses. One SNI may be associated with multiple LISs. ipOverSMDSTable OBJECT-TYPE SYNTAX SEQUENCE OF IpOverSMDSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of addressing information relevant to this entity's IP addresses." ::= { ipOverSMDS 1 } ipOverSMDSEntry OBJECT-TYPE SYNTAX IpOverSMDSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The addressing information for one of this entity's IP addresses." INDEX { ipOverSMDSIndex, ipOverSMDSAddress } ::= { ipOverSMDSTable 1 } IpOverSMDSEntry ::= SEQUENCE { ipOverSMDSIndex IfIndex, ipOverSMDSAddress IpAddress, ipOverSMDSHA SMDSAddress, ipOverSMDSLISGA SMDSAddress, ipOverSMDSARPReq SMDSAddress } ipOverSMDSIndex OBJECT-TYPEBrown & Tesink [Page 21]RFC 1694 SMDS Interface Objects August 1994 SYNTAX IfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the interface for which this entry contains management information. " ::= { ipOverSMDSEntry 1 } ipOverSMDSAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address to which this entry's addressing information pertains." ::= { ipOverSMDSEntry 2 } ipOverSMDSHA OBJECT-TYPE SYNTAX SMDSAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The SMDS Individual address of the IP station." ::= { ipOverSMDSEntry 3 } ipOverSMDSLISGA OBJECT-TYPE SYNTAX SMDSAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The SMDS Group Address that has been configured to identify the SMDS Subscriber-Network Interfaces (SNIs) of all members of the Logical IP Subnetwork (LIS) connected to the network supporting SMDS." ::= { ipOverSMDSEntry 4 } ipOverSMDSARPReq OBJECT-TYPE SYNTAX SMDSAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The SMDS address (individual or group) to which ARP Requests are to be sent." ::= { ipOverSMDSEntry 5 } -- The SMDS Carrier Selection groupBrown & Tesink [Page 22]RFC 1694 SMDS Interface Objects August 1994 -- This group is used as a place holder -- for carrier selection objects. smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 } -- The SIP Error Log sipErrorLog OBJECT IDENTIFIER ::= { sip 6 } sipL3PDUErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SipL3PDUErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the latest occurrence of the following syntactical SIP L3PDU errors: - Destination Address Field Format Error, The following pertains to the 60 least significant bits of the 64 bit address field. The 60 bits contained in the address subfield can be used to represent addresses up to 15 decimal digits. Each decimal digit shall be encoded into four bits using Binary Coded Decimal (BCD), with the most significant digit occurring left-most. If not all 15 digits are required, then the remainder of this field shall be padded on the right with bits set to one. An error is considered to have occurred: a). if the first four bits of the address subfield are not BCD, OR b). if the first four bits of the address subfield are populated with the country code value 0001, AND the 40 bits which follow are not Binary Coded Decimal (BCD) encoded values of the 10 digit addresses, OR the remaining 16 least significant bits are not populated with 1's, OR c). if the address subfield is not correct according to another numbering plan which is dependent upon the carrier assigning the numbers and offering SMDS. - Source Address Field Format Error, The description of this parameter is the same as the description of the Destination Address Field Format Error.Brown & Tesink [Page 23]RFC 1694 SMDS Interface Objects August 1994 - Invalid BAsize Field Value, An error is considered to have occurred when the BAsize field of an SIP L3PDU contains a value less that 32, greater than 9220 octets without the CRC32 field present, greater than 9224 octets with the CRC32 field present, or not equal to a multiple of 4 octets, - Invalid Header Extension Length Field Value, An error is considered to have occurred when the Header Extension Length field value is not equal 3. - Invalid Header Extension - Element Length, An error is considered to have occurred when the Header Extension - Element Length is greater than 12. - Invalid Header Extension - Version Element Position, Length, or Value, An error is considered to have occurred when a Version element with Length=3, Type=0, and Value=1 does not appear first within the Header Extension, or an element Type=0 appears somewhere other than within the first three octets in the Header Extension. - Invalid Header Extension - Carrier Selection Element Position, Length, Value or Format, An error is considered to have occurred when a Carrier Selection element does not appear second within the Header Extension, if the Element Type does not equal 1, the Element Length does not equal 4, 6, or 8, the Element Value field is not four BCD encoded decimal digits used in specifying the Carrier Identification Code (CIC), or the identified CIC code is invalid. - Header Extension PAD Error An error is considered to have occurred when the Header Extension PAD is 9 octets in length, or if the Header Extension PAD is greater than zeroBrown & Tesink [Page 24]RFC 1694 SMDS Interface Objects August 1994 octets in length and the Header Extension PAD does not follow all Header Extension elements or does not begin with at least one octet of all zeros. - BEtag Mismatch Error, An error is considered to have occurred when the Beginning-End Tags in the SIP L3PDU header and trailer are not equal. - BAsize Field not equal to Length Field Error, An error is considered to have occurred when the value of the BAsize Field does not equal the value of the Length Field. - Incorrect Length Error, and An error is considered to have occurred when the the Length field value is not equal to the portion of the SIP L3PDU which extends from the Destination Address field up to and including the CRC32 field (if present) or up to and including the PAD field (if the CRC32 field is not present). As an optional check, an error is considered to have occurred when the length of a partially received SIP L3PDU exceeds the BAsize value. - MRI Timeout Error. An error is considered to have occurred when the elapsed time between receipt of BOM and corresponding EOM exceeds the value of the MRI (Message Receive Interval) for a particular transport signal format. An entry is indexed by interface number and error type, and contains Source Address, Destination Address and a timestamp. All these errors are counted in the sipL3Errors counter. When sipL3PDUErrorTimeStamp is equal to zero, the SipL3PDUErrorEntry does not contain any valid
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -