⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1694.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 5 页
字号:
              ::= { sipDS3PLCPTable 1 }          SipDS3PLCPEntry  ::= SEQUENCE {              sipDS3PLCPIndex       IfIndex,              sipDS3PLCPSEFSs       Counter32,              sipDS3PLCPAlarmState  INTEGER,              sipDS3PLCPUASs        Counter32              }          sipDS3PLCPIndex  OBJECT-TYPE              SYNTAX      IfIndex              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The value of this object identifies the                 interface for which this entry contains management                 information.  "              ::= { sipDS3PLCPEntry 1 }Brown & Tesink                                                 [Page 19]RFC 1694                 SMDS Interface Objects              August 1994          sipDS3PLCPSEFSs OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "A DS3 Severely Errored Framing Second (SEFS) is a                 count of one-second intervals containing one or                 more SEF events.  A Severely Errored Framing (SEF)                 event is declared when an error in the A1 octet                 and an error in the A2 octet of a framing octet                 pair (i.e., errors in both framing octets), or two                 consecutive invalid and/or nonsequential Path                 Overhead Identifier octets are detected."              ::= { sipDS3PLCPEntry 2 }          sipDS3PLCPAlarmState OBJECT-TYPE              SYNTAX  INTEGER     {                          noAlarm (1),                          receivedFarEndAlarm (2),                          incomingLOF (3)                      }              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "This variable indicates if there is an alarm                 present for the DS3 PLCP.  The value                 receivedFarEndAlarm means that the DS3 PLCP has                 received an incoming Yellow Signal, the value                 incomingLOF means that the DS3 PLCP has declared a                 loss of frame (LOF) failure condition, and the                 value noAlarm means that there are no alarms                 present.  See TR-TSV-000773 for a description of                 alarm states."              ::= { sipDS3PLCPEntry 3 }          sipDS3PLCPUASs OBJECT-TYPE              SYNTAX      Counter32              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The counter associated with the number of                 Unavailable Seconds, as defined by TR-TSV-000773,                 encountered by the PLCP."              ::= { sipDS3PLCPEntry 4 }          -- The SMDS Applications group          -- Applications that have been identified for this group are:Brown & Tesink                                                 [Page 20]RFC 1694                 SMDS Interface Objects              August 1994          --          * IP-over-SMDS (details are specified in RFC 1209)          smdsApplications OBJECT IDENTIFIER ::= { sip 4 }          ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }          -- Although the objects in this group are read-only, at the          -- agent's discretion they may be made read-write so that the          -- management station, when appropriately authorized, may          -- change the addressing information related to the          -- configuration of a logical IP subnetwork implemented on          -- top of SMDS.          -- This table is necessary to support RFC1209 (IP-over-SMDS)          -- and gives information on the Group Addresses and ARP          -- Addresses used in the Logical IP subnetwork.          -- One SMDS address may be associated with multiple IP          -- addresses.  One SNI may be associated with multiple LISs.          ipOverSMDSTable OBJECT-TYPE              SYNTAX      SEQUENCE OF IpOverSMDSEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "The table of addressing information relevant to                 this entity's IP addresses."              ::= { ipOverSMDS 1 }          ipOverSMDSEntry OBJECT-TYPE              SYNTAX      IpOverSMDSEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "The addressing information for one of this                 entity's IP addresses."              INDEX   { ipOverSMDSIndex, ipOverSMDSAddress }              ::= { ipOverSMDSTable 1 }          IpOverSMDSEntry ::=              SEQUENCE {                 ipOverSMDSIndex       IfIndex,                 ipOverSMDSAddress     IpAddress,                 ipOverSMDSHA          SMDSAddress,                 ipOverSMDSLISGA       SMDSAddress,                 ipOverSMDSARPReq      SMDSAddress                 }          ipOverSMDSIndex OBJECT-TYPEBrown & Tesink                                                 [Page 21]RFC 1694                 SMDS Interface Objects              August 1994              SYNTAX      IfIndex              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The value of this object identifies the                 interface for which this entry contains management                 information. "              ::= { ipOverSMDSEntry 1 }          ipOverSMDSAddress OBJECT-TYPE               SYNTAX      IpAddress               MAX-ACCESS  read-only               STATUS      current               DESCRIPTION                 "The IP address to which this entry's addressing                 information pertains."              ::= { ipOverSMDSEntry 2 }          ipOverSMDSHA OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS Individual address of the IP station."              ::= { ipOverSMDSEntry 3 }          ipOverSMDSLISGA OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS Group Address that has been configured                 to identify the SMDS Subscriber-Network Interfaces                 (SNIs) of all members of the Logical IP Subnetwork                 (LIS) connected to the network supporting SMDS."              ::= { ipOverSMDSEntry 4 }          ipOverSMDSARPReq OBJECT-TYPE              SYNTAX      SMDSAddress              MAX-ACCESS  read-only              STATUS      current              DESCRIPTION                 "The SMDS address (individual or group) to which                 ARP Requests are to be sent."              ::= { ipOverSMDSEntry 5 }          -- The SMDS Carrier Selection groupBrown & Tesink                                                 [Page 22]RFC 1694                 SMDS Interface Objects              August 1994          -- This group is used as a place holder          -- for carrier selection objects.          smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 }          -- The SIP Error Log          sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }          sipL3PDUErrorTable OBJECT-TYPE              SYNTAX      SEQUENCE OF SipL3PDUErrorEntry              MAX-ACCESS  not-accessible              STATUS      current              DESCRIPTION                 "A table that contains the latest occurrence of                 the following syntactical SIP L3PDU errors:                 - Destination Address Field Format Error,                 The following pertains to the 60 least significant                 bits of the 64 bit address field.  The 60 bits                 contained in the address subfield can be used to                 represent addresses up to 15 decimal digits.  Each                 decimal digit shall be encoded into four bits                 using Binary Coded Decimal (BCD), with the most                 significant digit occurring left-most.  If not all                 15 digits are required, then the remainder of this                 field shall be padded on the right with bits set                 to one.  An error is considered to have occurred:                 a).  if the first four bits of the address                 subfield are not BCD, OR b).  if the first four                 bits of the address subfield are populated with                 the country code value 0001, AND the 40 bits which                 follow are not Binary Coded Decimal (BCD) encoded                 values of the 10 digit addresses, OR the remaining                 16 least significant bits are not populated with                 1's, OR c).  if the address subfield is not                 correct according to another numbering plan which                 is dependent upon the carrier assigning the                 numbers and offering SMDS.                 - Source Address Field Format Error,                 The description of this parameter is the same as                 the description of the Destination Address Field                 Format Error.Brown & Tesink                                                 [Page 23]RFC 1694                 SMDS Interface Objects              August 1994                 - Invalid BAsize Field Value,                 An error is considered to have occurred when the                 BAsize field of an SIP L3PDU contains a value less                 that 32, greater than 9220 octets without the                 CRC32 field present, greater than 9224 octets with                 the CRC32 field present, or not equal to a                 multiple of 4 octets,                 - Invalid Header Extension Length Field Value,                 An error is considered to have occurred when the                 Header Extension Length field value is not equal                 3.                 - Invalid Header Extension - Element Length,                 An error is considered to have occurred when the                 Header Extension - Element Length is greater than                 12.                 - Invalid Header Extension - Version Element                 Position, Length, or Value,                 An error is considered to have occurred when a                 Version element with Length=3, Type=0, and Value=1                 does not appear first within the Header Extension,                 or an element Type=0 appears somewhere other than                 within the first three octets in the Header                 Extension.                 - Invalid Header Extension - Carrier Selection                 Element Position, Length, Value or Format,                 An error is considered to have occurred when a                 Carrier Selection element does not appear second                 within the Header Extension, if the Element Type                 does not equal 1, the Element Length does not                 equal 4, 6, or 8, the Element Value field is not                 four BCD encoded decimal digits used in specifying                 the Carrier Identification Code (CIC), or the                 identified CIC code is invalid.                 - Header Extension PAD Error                 An error is considered to have occurred when the                 Header Extension PAD is 9 octets in length, or if                 the Header Extension PAD is greater than zeroBrown & Tesink                                                 [Page 24]RFC 1694                 SMDS Interface Objects              August 1994                 octets in length and the Header Extension PAD does                 not follow all Header Extension elements or does                 not begin with at least one octet of all zeros.                 - BEtag Mismatch Error,                 An error is considered to have occurred when the                 Beginning-End Tags in the SIP L3PDU header and                 trailer are not equal.                 - BAsize Field not equal to Length Field Error,                 An error is considered to have occurred when the                 value of the BAsize Field does not equal the value                 of the Length Field.                 - Incorrect Length Error, and                 An error is considered to have occurred when the                 the Length field value is not equal to the portion                 of the SIP L3PDU which extends from the                 Destination Address field up to and including the                 CRC32 field (if present) or up to and including                 the PAD field (if the CRC32 field is not present).                 As an optional check, an error is considered to                 have occurred when the length of a partially                 received SIP L3PDU exceeds the BAsize value.                 - MRI Timeout Error.                 An error is considered to have occurred when the                 elapsed time between receipt of BOM and                 corresponding EOM exceeds the value of the MRI                 (Message Receive Interval) for a particular                 transport signal format.                 An entry is indexed by interface number and error                 type, and contains Source Address, Destination                 Address and a timestamp. All these errors are                 counted in the sipL3Errors counter.  When                 sipL3PDUErrorTimeStamp is equal to zero, the                 SipL3PDUErrorEntry does not contain any valid

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -