📄 rfc1694.txt
字号:
errors but excluding addressing-related errors) and were discarded. Includes both group addressed L3PDUs and L3PDUs containing an individual destination address." ::= { sipL3Entry 8 } sipL3InvalidSMDSAddressTypes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated -- Moved to ifTable -- ifInUnknownProtos defined in [9] must be used instead. DESCRIPTION "The number of SIP Level 3 PDUs received from the remote system that had the Source or Destination Address_Type subfields, (the four most significant bits of the 64 bit address field), not equal to the value 1100 or 1110. Also, an error is considered to have occurred if the Address_Type field for a Source Address, the four most significant bits of the 64 bits, is equal to 1110 (a group address)." ::= { sipL3Entry 9 } sipL3VersionSupport OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value which indicates the version(s) of SIPBrown & Tesink [Page 13]RFC 1694 SMDS Interface Objects August 1994 that this interface supports. The value is a sum. This sum initially takes the value zero. For each version, V, that this interface supports, 2 raised to (V - 1) is added to the sum. For example, a port supporting versions 1 and 2 would have a value of (2^(1-1)+2^(2-1))=3. The sipL3VersionSupport is effectively a bit mask with Version 1 equal to the least significant bit (LSB)." ::= { sipL3Entry 10 } -- The SIP Level 2 Group sipL2Table OBJECT-TYPE SYNTAX SEQUENCE OF SipL2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains SIP L2PDU parameters and state variables, one entry per SIP L2 interface." ::= { sip 2 } sipL2Entry OBJECT-TYPE SYNTAX SipL2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains SIP L2 parameters and state variables." INDEX { sipL2Index } ::= { sipL2Table 1 } SipL2Entry ::= SEQUENCE { sipL2Index IfIndex, sipL2ReceivedCounts Counter32, sipL2SentCounts Counter32, sipL2HcsOrCRCErrors Counter32, sipL2PayloadLengthErrors Counter32, sipL2SequenceNumberErrors Counter32, sipL2MidCurrentlyActiveErrors Counter32, sipL2BomOrSSMsMIDErrors Counter32, sipL2EomsMIDErrors Counter32 } sipL2Index OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-onlyBrown & Tesink [Page 14]RFC 1694 SMDS Interface Objects August 1994 STATUS current DESCRIPTION "The value of this object identifies the SIP interface for which this entry contains management information." ::= { sipL2Entry 1 } sipL2ReceivedCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SIP Level 2 PDUs received from the remote system across the SNI. The total includes only unerrored L2PDUs." ::= { sipL2Entry 2 } sipL2SentCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SIP Level 2 PDUs that have been sent by this system across the SNI." ::= { sipL2Entry 3 } -- The following error types are counted, and -- preclude sipL2ReceivedCounts to be incremented: -- sipL2HcsOrCRCErrors -- sipL2PayloadLengthErrors -- sipL2SequenceNumberErrors -- sipL2BomOrSSMsMIDErrors -- sipL2EomsMIDErrors -- The receipt of SIP Level 2 PDUs which are BOMs and -- for with a MID that is already active will cause -- sipL2MidCurrentlyActiveErrors to increment. -- Any already accumulated (correct) segmentation -- units are discarded.The sipL2ReceivedCounts -- is incremented by 1. Thus, -- sipL2ReceivedCounts defines the number of -- correct SIP Level 2 PDUs delivered to the reassembly -- process. sipL2HcsOrCRCErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTIONBrown & Tesink [Page 15]RFC 1694 SMDS Interface Objects August 1994 "The number of received SIP Level 2 PDUs that were discovered to have either a Header Check Sequence error or a Payload CRC violation." ::= { sipL2Entry 4 } sipL2PayloadLengthErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received SIP Level 2 PDUs that had Payload Length errors that fall in the following specifications: - SSM L2_PDU payload length field value less - than 28 octets or greater than 44 octets, - BOM or COM L2_PDU payload length field not - equal to 44 octets, - EOM L2_PDU payload length field value less - than 4 octets or greater than 44 octets." ::= { sipL2Entry 5 } sipL2SequenceNumberErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received SIP Level 2 PDUs that had a sequence number within the L2PDU not equal to the expected sequence number of the SMDS SS receive process." ::= { sipL2Entry 6 } sipL2MidCurrentlyActiveErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received SIP Level 2 PDUs that are BOMs for which an active receive process is already started." ::= { sipL2Entry 7 } sipL2BomOrSSMsMIDErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTIONBrown & Tesink [Page 16]RFC 1694 SMDS Interface Objects August 1994 "The number of received SIP Level 2 PDUs that are SSMs with a MID not equal to zero or are BOMs with MIDs equal to zero." ::= { sipL2Entry 8 } sipL2EomsMIDErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received SIP Level 2 PDUs that are EOMs for which there is no active receive process for the MID (i.e., the receipt of an EOM which does not correspond to a BOM) OR the EOM has a MID equal to zero." ::= { sipL2Entry 9 } -- The SIP PLCP Group sipPLCP OBJECT IDENTIFIER ::= { sip 3 } -- The DS1 PLCP Group sipDS1PLCPTable OBJECT-TYPE SYNTAX SEQUENCE OF SipDS1PLCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains SIP DS1 PLCP parameters and state variables, one entry per SIP port." ::= { sipPLCP 1 } sipDS1PLCPEntry OBJECT-TYPE SYNTAX SipDS1PLCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains SIP DS1 PLCP parameters and state variables." INDEX { sipDS1PLCPIndex } ::= { sipDS1PLCPTable 1 } SipDS1PLCPEntry ::= SEQUENCE { sipDS1PLCPIndex IfIndex, sipDS1PLCPSEFSs Counter32, sipDS1PLCPAlarmState INTEGER,Brown & Tesink [Page 17]RFC 1694 SMDS Interface Objects August 1994 sipDS1PLCPUASs Counter32 } sipDS1PLCPIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the interface for which this entry contains management information. " ::= { sipDS1PLCPEntry 1 } sipDS1PLCPSEFSs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A DS1 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected." ::= { sipDS1PLCPEntry 2 } sipDS1PLCPAlarmState OBJECT-TYPE SYNTAX INTEGER { noAlarm (1), receivedFarEndAlarm (2), incomingLOF (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates if there is an alarm present for the DS1 PLCP. The value receivedFarEndAlarm means that the DS1 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS1 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states." ::= { sipDS1PLCPEntry 3 }Brown & Tesink [Page 18]RFC 1694 SMDS Interface Objects August 1994 sipDS1PLCPUASs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP." ::= { sipDS1PLCPEntry 4 } -- The DS3 PLCP Group sipDS3PLCPTable OBJECT-TYPE SYNTAX SEQUENCE OF SipDS3PLCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains SIP DS3 PLCP parameters and state variables, one entry per SIP port." ::= { sipPLCP 2 } sipDS3PLCPEntry OBJECT-TYPE SYNTAX SipDS3PLCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This list contains SIP DS3 PLCP parameters and state variables." INDEX { sipDS3PLCPIndex }
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -