📄 rfc1289.txt
字号:
DECnet Phase IV MIB Working Group [Page 20]RFC 1289 DECnet Phase IV MIB December 1991 phivRouteCountPacketFmtErr OBJECT-TYPE SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Number of packet format errors." ::= { routing 19 } phivRouteCountPtlRteUpdtLoss OBJECT-TYPE SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Number of partial routing update losses." ::= { routing 20 } phivRouteCountVerifReject OBJECT-TYPE SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Number of verification rejects." ::= { routing 21 } -- Level 1 Routing Table phivLevel1RouteTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivLevel1RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the currently known DECnet Phase IV Routes." ::= { routing 22 } phivLevel1RouteEntry OBJECT-TYPE SYNTAX PhivLevel1RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the currently known DECnet Phase IV Routes." INDEX { phivLevel1RouteNodeAddr } ::= { phivLevel1RouteTable 1 } PhivLevel1RouteEntry ::= SEQUENCE { phivLevel1RouteNodeAddrDECnet Phase IV MIB Working Group [Page 21]RFC 1289 DECnet Phase IV MIB December 1991 PhivAddr, phivLevel1RouteCircuitIndex INTEGER, phivLevel1RouteCost INTEGER (0..65535), phivLevel1RouteHops INTEGER (0..127), phivLevel1RouteNextNode PhivAddr } phivLevel1RouteNodeAddr OBJECT-TYPE SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This value is the address of the node about which routing information is contained in this level 1 routing table." ::= { phivLevel1RouteEntry 1 } phivLevel1RouteCircuitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known circuit. This is the index to the circuit state table and is the same value as phivCircuitIndex." ::= { phivLevel1RouteEntry 2 } phivLevel1RouteCost OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the total cost over the current path to the destination node. Cost is a positive integer value associated with using a circuit. Routing routes messages (data) along the path between two nodes with the smallest cost. COST is kept on a remote node basis." ::= { phivLevel1RouteEntry 3 } phivLevel1RouteHops OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTIONDECnet Phase IV MIB Working Group [Page 22]RFC 1289 DECnet Phase IV MIB December 1991 "This read-only parameter represents the number of hops over to a destination node. A hop is Routing value representing the logical distance between two nodes in a network. HOPS is kept on a remote node basis." ::= { phivLevel1RouteEntry 4 } phivLevel1RouteNextNode OBJECT-TYPE SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only value indicates the next node on the circuit used to get to the node under scrutiny (next hop)." ::= { phivLevel1RouteEntry 5 } -- Additional routing parameters phivRouteCountZeroCount OBJECT-TYPE SYNTAX INTEGER { other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this value is set to 2, the following objects are set to Zero: phivRouteCountAgedPktLoss, phivRouteCountNodeUnrPktLoss, phivRouteCountOutRngePktLoss, phivRouteCountOverSzePktLoss, phivRouteCountPacketFmtErr, phivRouteCountPtlRteUpdtLoss, and phivRouteCountVerifReject." ::= { routing 23 } phivRouteSystemAddr OBJECT-TYPE SYNTAX PhivAddr ACCESS read-only STATUS mandatory DESCRIPTION "DECnet Phase IV node address." ::= { routing 24 }DECnet Phase IV MIB Working Group [Page 23]RFC 1289 DECnet Phase IV MIB December 1991 -- Circuit Group -- The implementation of the Circuit Group is mandatory for -- all systems. -- Circuit Parameters Table phivCircuitParametersTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the parameters associated with all circuits currently known." ::= {circuit 1 } phivCircuitParametersEntry OBJECT-TYPE SYNTAX PhivCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters information about all circuits currently known." INDEX { phivCircuitIndex } ::= { phivCircuitParametersTable 1 } PhivCircuitParametersEntry ::= SEQUENCE { phivCircuitIndex INTEGER, phivCircuitLineIndex INTEGER, phivCircuitCommonState INTEGER, phivCircuitCommonSubState INTEGER, phivCircuitCommonName DisplayString, phivCircuitExecRecallTimer INTEGER (0..65535), phivCircuitCommonType INTEGER, phivCircuitService INTEGER, phivCircuitExecCost INTEGER (1..25), phivCircuitExecHelloTimerDECnet Phase IV MIB Working Group [Page 24]RFC 1289 DECnet Phase IV MIB December 1991 INTEGER (1..8191) } phivCircuitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known circuit." ::= { phivCircuitParametersEntry 1 } phivCircuitLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The line on which this circuit is active. This is the same as the IfIndex." ::= { phivCircuitParametersEntry 2 } phivCircuitCommonState OBJECT-TYPE SYNTAX INTEGER { on (1), off (2), service (3), cleared (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the circuit's Network Management operational state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155." ::= { phivCircuitParametersEntry 3 } phivCircuitCommonSubState OBJECT-TYPE SYNTAX INTEGER { starting (1), reflecting (2), looping (3), loading (4), dumping (5), triggering (6), autoservice (7), autoloading (8), autodumping (9), autotriggering (10), synchronizing (11),DECnet Phase IV MIB Working Group [Page 25]RFC 1289 DECnet Phase IV MIB December 1991 failed (12), running (13) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the circuit's Network Management operational and service substate. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155." ::= { phivCircuitParametersEntry 4 } phivCircuitCommonName OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..16) ) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the circuit entry in the table, for example, SVA-0 or in a level 2 router ASYNC-8 or ETHER-1)." ::= { phivCircuitParametersEntry 5 } phivCircuitExecRecallTimer OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter represents the minimum number of seconds to wait before restarting the circuit. A value of 0 indicates not timer is running." ::= { phivCircuitParametersEntry 6 } phivCircuitCommonType OBJECT-TYPE SYNTAX INTEGER { ddcmp-point (1), ddcmp-control (2), ddcmp-tributary (3), x25 (4), ddcmp-dmc (5), ethernet (6), ci (7), qp2-dte20 (8), bisync (9), other (14), fddi (15) } ACCESS read-only STATUS mandatory DESCRIPTIONDECnet Phase IV MIB Working Group [Page 26]RFC 1289 DECnet Phase IV MIB December 1991 "Represents the type of the circuit. For X.25 circuits, the value must be set to X25. For DDCMP and Ethernet circuits it is read only and is the same value as the protocol of the associated line. NOTE: Values 1 - 5 are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155." ::= { phivCircuitParametersEntry 7 } phivCircuitService OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This value indicates whether or not Network Management allows service operations on a circuit. The values for service-control are as follows: ENABLED SERVICE state and/or service functions are allowed. DISABLED SERVICE state and/or service functions are not allowed. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -