📄 rfc1318.txt
字号:
paraInSigTable OBJECT-TYPE SYNTAX SEQUENCE OF ParaInSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of port input control signal entries." ::= { para 3 } paraInSigEntry OBJECT-TYPE SYNTAX ParaInSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Input control signal status for a hardware port." INDEX { paraInSigPortIndex, paraInSigName } ::= { paraInSigTable 1 } ParaInSigEntry ::= SEQUENCE { paraInSigPortIndex INTEGER, paraInSigName INTEGER, paraInSigStateCharacter MIB Working Group [Page 6]RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992 INTEGER, paraInSigChanges Counter } paraInSigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of paraPortIndex for the port to which this entry belongs." ::= { paraInSigEntry 1 } paraInSigName OBJECT-TYPE SYNTAX INTEGER { power(1), online(2), busy(3), paperout(4), fault(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Identification of a hardware signal." ::= { paraInSigEntry 2 } paraInSigState OBJECT-TYPE SYNTAX INTEGER { none(1), on(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current signal state." ::= { paraInSigEntry 3 } paraInSigChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'." ::= { paraInSigEntry 4 } -- the Output Signal table paraOutSigTable OBJECT-TYPE SYNTAX SEQUENCE OF ParaOutSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTIONCharacter MIB Working Group [Page 7]RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992 "A list of port output control signal entries." ::= { para 4 } paraOutSigEntry OBJECT-TYPE SYNTAX ParaOutSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output control signal status for a hardware port." INDEX { paraOutSigPortIndex, paraOutSigName } ::= { paraOutSigTable 1 } ParaOutSigEntry ::= SEQUENCE { paraOutSigPortIndex INTEGER, paraOutSigName INTEGER, paraOutSigState INTEGER, paraOutSigChanges Counter } paraOutSigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of paraPortIndex for the port to which this entry belongs." ::= { paraOutSigEntry 1 } paraOutSigName OBJECT-TYPE SYNTAX INTEGER { power(1), online(2), busy(3), paperout(4), fault(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Identification of a hardware signal." ::= { paraOutSigEntry 2 } paraOutSigState OBJECT-TYPE SYNTAX INTEGER { none(1), on(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current signal state."Character MIB Working Group [Page 8]RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992 ::= { paraOutSigEntry 3 } paraOutSigChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'." ::= { paraOutSigEntry 4 } END6. Acknowledgements Based on several private MIBs, this document was produced by the Character MIB Working Group: Anne Ambler, Spider Charles Bazaar, Emulex Christopher Bucci, Datability Anthony Chung, Hughes LAN Systems George Conant, Xyplex John Cook, Chipcom James Davin, MIT-LCS Shawn Gallagher, DEC Tom Grant, Xylogics Frank Huang, Emulex David Jordan, Emulex Satish Joshi, SynOptics Frank Kastenholz, Clearpoint Ken Key, University of Tennessee Jim Kinder, Fibercom Rajeev Kochhar, 3Com John LoVerso, Xylogics Keith McCloghrie, Hughes LAN Systems Donald Merritt, BRL David Perkins, 3Com Jim Reinstedler, Ungerman-Bass Marshall Rose, PSI Ron Strich, SSDS Dean Throop, DG Bill Townsend, Xylogics Jesse Walker, DEC David Waitzman, BBN Bill Westfield, ciscoCharacter MIB Working Group [Page 9]RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 19927. References [1] Cerf, V., "IAB Recommendations for the Development of Internet Network Management Standards", RFC 1052, NRI, April 1988. [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review Group", RFC 1109, NRI, August 1989. [3] Rose M., and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based internets", RFC 1155, Performance Systems International, Hughes LAN Systems, May 1990. [4] McCloghrie K., and M. Rose, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1156, Hughes LAN Systems, Performance Systems International, May 1990. [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, Simple Network Management Protocol", RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990. [6] McCloghrie K., and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1213, Performance Systems International, March 1991. [7] Information processing systems - Open Systems Interconnection - Specification of Abstract Syntax Notation One (ASN.1), International Organization for Standardization, International Standard 8824, December 1987. [8] Information processing systems - Open Systems Interconnection - Specification of Basic Encoding Rules for Abstract Notation One (ASN.1), International Organization for Standardization, International Standard 8825, December 1987. [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991. [10] Rose, M., Editor, "A Convention for Defining Traps for use with the SNMP", RFC 1215, Performance Systems International, March 1991.8. Security Considerations Security issues are not discussed in this memo.Character MIB Working Group [Page 10]RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 19929. Author's Address Bob Stewart Xyplex, Inc. 330 Codman Hill Road Boxborough, MA 01719 Phone: (508) 264-9900 EMail: rlstewart@eng.xyplex.comCharacter MIB Working Group [Page 11]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -