⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2128.txt

📁 著名的RFC文档,其中有一些文档是已经翻译成中文的的.
💻 TXT
📖 第 1 页 / 共 5 页
字号:
        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "This is the ifIndex value of the peer table entry             to which this call was made. If a peer table entry             for this call does not exist or is unknown, the value             of this object will be zero."        ::= { callActiveEntry 6 }callActiveLogicalIfIndex OBJECT-TYPE        SYNTAX      InterfaceIndexOrZeroRoeck                   Standards Track                        [Page 20]RFC 2128                    Dial Control MIB                  March 1997        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "This is the ifIndex value of the logical interface through             which this call was made. For ISDN media, this would be             the ifIndex of the B channel which was used for this call.             If the ifIndex value is unknown, the value of this object             will be zero."        ::= { callActiveEntry 7 }callActiveConnectTime OBJECT-TYPE        SYNTAX      TimeStamp        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The value of sysUpTime when the call was connected.             If the call is not connected, this object will have a             value of zero."        ::= { callActiveEntry 8 }callActiveCallState OBJECT-TYPE        SYNTAX      INTEGER {            unknown(1),            connecting(2),            connected(3),            active(4)        }        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The current call state.             unknown(1)     - The call state is unknown.             connecting(2)  - A connection attempt (outgoing call)                              is being made.             connected(3)   - An incoming call is in the process                              of validation.             active(4)      - The call is active.            "        ::= { callActiveEntry 9 }callActiveCallOrigin OBJECT-TYPE        SYNTAX      INTEGER {            originate(1),            answer(2),            callback(3)        }        MAX-ACCESS  read-only        STATUS      currentRoeck                   Standards Track                        [Page 21]RFC 2128                    Dial Control MIB                  March 1997        DESCRIPTION            "The call origin."        ::= { callActiveEntry 10 }callActiveChargedUnits OBJECT-TYPE        SYNTAX      AbsoluteCounter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The number of charged units for this connection.             For incoming calls or if charging information is             not supplied by the switch, the value of this object             will be zero."        ::= { callActiveEntry 11 }callActiveInfoType OBJECT-TYPE        SYNTAX      INTEGER {            other(1),                   -- e.g. for non-isdn media            speech(2),            unrestrictedDigital(3),     -- 64k/s data            unrestrictedDigital56(4),   -- with 56k rate adaption            restrictedDigital(5),            audio31(6),                 -- 3.1 kHz audio            audio7(7),                  -- 7 kHz audio            video(8),            packetSwitched(9),            fax(10)        }        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The information type for this call."        ::= { callActiveEntry 12 }callActiveTransmitPackets OBJECT-TYPE        SYNTAX      AbsoluteCounter32        MAX-ACCESS  read-only        STATUS     current        DESCRIPTION            "The number of packets which were transmitted for this             call."        ::= { callActiveEntry 13 }callActiveTransmitBytes OBJECT-TYPE        SYNTAX      AbsoluteCounter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTIONRoeck                   Standards Track                        [Page 22]RFC 2128                    Dial Control MIB                  March 1997            "The number of bytes which were transmitted for this             call."        ::= { callActiveEntry 14 }callActiveReceivePackets OBJECT-TYPE        SYNTAX      AbsoluteCounter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The number of packets which were received for this             call."        ::= { callActiveEntry 15 }callActiveReceiveBytes OBJECT-TYPE        SYNTAX      AbsoluteCounter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The number of bytes which were received for this call."        ::= { callActiveEntry 16 }---- the call history group--callHistory OBJECT IDENTIFIER ::= { dialControlMibObjects 4 }callHistoryTableMaxLength OBJECT-TYPE        SYNTAX      INTEGER (0..2147483647)        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The upper limit on the number of entries that the             callHistoryTable may contain.  A value of 0             will prevent any history from being retained. When             this table is full, the oldest entry will be deleted             and the new one will be created."        ::= { callHistory 1 }callHistoryRetainTimer OBJECT-TYPE        SYNTAX      INTEGER (0..2147483647)        UNITS       "minutes"        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The minimum amount of time that an callHistoryEntry             will be maintained before being deleted. A value of             0 will prevent any history from being retained in theRoeck                   Standards Track                        [Page 23]RFC 2128                    Dial Control MIB                  March 1997             callHistoryTable, but will neither prevent callCompletion             traps being generated nor affect other tables."        ::= { callHistory 2 }-- callHistoryTable-- Table to store the past call information. The Destination number-- and the call connect and disconnect time, the disconnection cause-- are stored. These calls could be circuit switched or they could-- be virtual circuits. History of each and every call is stored,-- of successful calls as well as of unsuccessful and rejected calls.-- An entry will be created when a call is cleared.callHistoryTable OBJECT-TYPE        SYNTAX      SEQUENCE OF CallHistoryEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "A table containing information about specific             calls to a specific destination."        ::= { callHistory 3 }callHistoryEntry OBJECT-TYPE        SYNTAX      CallHistoryEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "The information regarding a single Connection."        INDEX       { callActiveSetupTime, callActiveIndex }        ::= { callHistoryTable 1 }CallHistoryEntry ::=        SEQUENCE {            callHistoryPeerAddress               DisplayString,            callHistoryPeerSubAddress            DisplayString,            callHistoryPeerId                    INTEGER,            callHistoryPeerIfIndex               INTEGER,            callHistoryLogicalIfIndex            InterfaceIndex,            callHistoryDisconnectCause           OCTET STRING,            callHistoryDisconnectText            DisplayString,            callHistoryConnectTime               TimeStamp,            callHistoryDisconnectTime            TimeStamp,            callHistoryCallOrigin                INTEGER,            callHistoryChargedUnits              AbsoluteCounter32,            callHistoryInfoType                  INTEGER,            callHistoryTransmitPackets           AbsoluteCounter32,            callHistoryTransmitBytes             AbsoluteCounter32,            callHistoryReceivePackets            AbsoluteCounter32,Roeck                   Standards Track                        [Page 24]RFC 2128                    Dial Control MIB                  March 1997            callHistoryReceiveBytes              AbsoluteCounter32        }callHistoryPeerAddress OBJECT-TYPE        SYNTAX      DisplayString        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The number this call was connected to. If the number is             not available, then it will have a length of zero."        ::= { callHistoryEntry 1 }callHistoryPeerSubAddress OBJECT-TYPE        SYNTAX      DisplayString        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The subaddress this call was connected to. If the subaddress             is undefined or not available, this will be a zero length             string."        ::= { callHistoryEntry 2 }callHistoryPeerId OBJECT-TYPE        SYNTAX      INTEGER (0..2147483647)        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "This is the Id value of the peer table entry             to which this call was made. If a peer table entry             for this call does not exist, the value of this object             will be zero."        ::= { callHistoryEntry 3 }callHistoryPeerIfIndex OBJECT-TYPE        SYNTAX      INTEGER (0..2147483647)        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "This is the ifIndex value of the peer table entry             to which this call was made. If a peer table entry             for this call does not exist, the value of this object             will be zero."        ::= { callHistoryEntry 4 }callHistoryLogicalIfIndex OBJECT-TYPE        SYNTAX      InterfaceIndex        MAX-ACCESS  read-only        STATUS      currentRoeck                   Standards Track                        [Page 25]RFC 2128                    Dial Control MIB                  March 1997        DESCRIPTION            "This is the ifIndex value of the logical interface through             which this call was made. For ISDN media, this would be             the ifIndex of the B channel which was used for this call."        ::= { callHistoryEntry 5 }callHistoryDisconnectCause OBJECT-TYPE        SYNTAX      OCTET STRING (SIZE (0..4))        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The encoded network cause value associated with this call.             The value of this object will depend on the interface type             as well as on the protocol and protocol version being             used on this interface. Some references for possible cause             values are given below."        REFERENCE            "- Bellcore SR-NWT-001953, Generic Guidelines for               ISDN Terminal Equipment On Basic Access Interfaces,               chapter 5.2.5.8.             - Bellcore SR-NWT-002343, ISDN Primary Rate Interface               Generic Guidelines for Customer Premises Equipment,               chapter 8.2.5.8.             - ITU-T Q.931, Appendix I.             - ITU-T X.25, CAUSE and DIAGNOSTIC field values.             - German Telekom FTZ 1TR6, chapter 3.2.3.4.4.4."        ::= { callHistoryEntry 6 }callHistoryDisconnectText OBJECT-TYPE        SYNTAX      DisplayString        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "ASCII text describing the reason for call termination.             This object exists because it would be impossible for             a management station to store all possible cause values             for all types of interfaces. It should be used only if             a management station is unable to decode the value of             dialCtlPeerStatsLastDisconnectCause."        ::= { callHistoryEntry 7 }callHistoryConnectTime OBJECT-TYPE        SYNTAX      TimeStamp        MAX-ACCESS  read-only        STATUS      current        DESCRIPTIONRoeck                   Standards Track                        [Page 26]RFC 2128                    Dial Control MIB                  March 1997            "The value of sysUpTime when the call was connected."        ::= { callHistoryEntry 8 }callHistoryDisconnectTime OBJECT-TYPE        SYNTAX      TimeStamp        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "The value of sysUpTime when the call was disconnected."        ::= { callHistoryEntry 9 }callHistoryCallOrigin OBJECT-TYPE        SYNTAX      INTEGER {            originate(1),

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -