📄 rfc2128.txt
字号:
MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex value of the peer table entry to which this call was made. If a peer table entry for this call does not exist or is unknown, the value of this object will be zero." ::= { callActiveEntry 6 }callActiveLogicalIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZeroRoeck Standards Track [Page 20]RFC 2128 Dial Control MIB March 1997 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex value of the logical interface through which this call was made. For ISDN media, this would be the ifIndex of the B channel which was used for this call. If the ifIndex value is unknown, the value of this object will be zero." ::= { callActiveEntry 7 }callActiveConnectTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the call was connected. If the call is not connected, this object will have a value of zero." ::= { callActiveEntry 8 }callActiveCallState OBJECT-TYPE SYNTAX INTEGER { unknown(1), connecting(2), connected(3), active(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current call state. unknown(1) - The call state is unknown. connecting(2) - A connection attempt (outgoing call) is being made. connected(3) - An incoming call is in the process of validation. active(4) - The call is active. " ::= { callActiveEntry 9 }callActiveCallOrigin OBJECT-TYPE SYNTAX INTEGER { originate(1), answer(2), callback(3) } MAX-ACCESS read-only STATUS currentRoeck Standards Track [Page 21]RFC 2128 Dial Control MIB March 1997 DESCRIPTION "The call origin." ::= { callActiveEntry 10 }callActiveChargedUnits OBJECT-TYPE SYNTAX AbsoluteCounter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of charged units for this connection. For incoming calls or if charging information is not supplied by the switch, the value of this object will be zero." ::= { callActiveEntry 11 }callActiveInfoType OBJECT-TYPE SYNTAX INTEGER { other(1), -- e.g. for non-isdn media speech(2), unrestrictedDigital(3), -- 64k/s data unrestrictedDigital56(4), -- with 56k rate adaption restrictedDigital(5), audio31(6), -- 3.1 kHz audio audio7(7), -- 7 kHz audio video(8), packetSwitched(9), fax(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The information type for this call." ::= { callActiveEntry 12 }callActiveTransmitPackets OBJECT-TYPE SYNTAX AbsoluteCounter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets which were transmitted for this call." ::= { callActiveEntry 13 }callActiveTransmitBytes OBJECT-TYPE SYNTAX AbsoluteCounter32 MAX-ACCESS read-only STATUS current DESCRIPTIONRoeck Standards Track [Page 22]RFC 2128 Dial Control MIB March 1997 "The number of bytes which were transmitted for this call." ::= { callActiveEntry 14 }callActiveReceivePackets OBJECT-TYPE SYNTAX AbsoluteCounter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets which were received for this call." ::= { callActiveEntry 15 }callActiveReceiveBytes OBJECT-TYPE SYNTAX AbsoluteCounter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes which were received for this call." ::= { callActiveEntry 16 }---- the call history group--callHistory OBJECT IDENTIFIER ::= { dialControlMibObjects 4 }callHistoryTableMaxLength OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The upper limit on the number of entries that the callHistoryTable may contain. A value of 0 will prevent any history from being retained. When this table is full, the oldest entry will be deleted and the new one will be created." ::= { callHistory 1 }callHistoryRetainTimer OBJECT-TYPE SYNTAX INTEGER (0..2147483647) UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum amount of time that an callHistoryEntry will be maintained before being deleted. A value of 0 will prevent any history from being retained in theRoeck Standards Track [Page 23]RFC 2128 Dial Control MIB March 1997 callHistoryTable, but will neither prevent callCompletion traps being generated nor affect other tables." ::= { callHistory 2 }-- callHistoryTable-- Table to store the past call information. The Destination number-- and the call connect and disconnect time, the disconnection cause-- are stored. These calls could be circuit switched or they could-- be virtual circuits. History of each and every call is stored,-- of successful calls as well as of unsuccessful and rejected calls.-- An entry will be created when a call is cleared.callHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF CallHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing information about specific calls to a specific destination." ::= { callHistory 3 }callHistoryEntry OBJECT-TYPE SYNTAX CallHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information regarding a single Connection." INDEX { callActiveSetupTime, callActiveIndex } ::= { callHistoryTable 1 }CallHistoryEntry ::= SEQUENCE { callHistoryPeerAddress DisplayString, callHistoryPeerSubAddress DisplayString, callHistoryPeerId INTEGER, callHistoryPeerIfIndex INTEGER, callHistoryLogicalIfIndex InterfaceIndex, callHistoryDisconnectCause OCTET STRING, callHistoryDisconnectText DisplayString, callHistoryConnectTime TimeStamp, callHistoryDisconnectTime TimeStamp, callHistoryCallOrigin INTEGER, callHistoryChargedUnits AbsoluteCounter32, callHistoryInfoType INTEGER, callHistoryTransmitPackets AbsoluteCounter32, callHistoryTransmitBytes AbsoluteCounter32, callHistoryReceivePackets AbsoluteCounter32,Roeck Standards Track [Page 24]RFC 2128 Dial Control MIB March 1997 callHistoryReceiveBytes AbsoluteCounter32 }callHistoryPeerAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The number this call was connected to. If the number is not available, then it will have a length of zero." ::= { callHistoryEntry 1 }callHistoryPeerSubAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The subaddress this call was connected to. If the subaddress is undefined or not available, this will be a zero length string." ::= { callHistoryEntry 2 }callHistoryPeerId OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Id value of the peer table entry to which this call was made. If a peer table entry for this call does not exist, the value of this object will be zero." ::= { callHistoryEntry 3 }callHistoryPeerIfIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the ifIndex value of the peer table entry to which this call was made. If a peer table entry for this call does not exist, the value of this object will be zero." ::= { callHistoryEntry 4 }callHistoryLogicalIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS currentRoeck Standards Track [Page 25]RFC 2128 Dial Control MIB March 1997 DESCRIPTION "This is the ifIndex value of the logical interface through which this call was made. For ISDN media, this would be the ifIndex of the B channel which was used for this call." ::= { callHistoryEntry 5 }callHistoryDisconnectCause OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The encoded network cause value associated with this call. The value of this object will depend on the interface type as well as on the protocol and protocol version being used on this interface. Some references for possible cause values are given below." REFERENCE "- Bellcore SR-NWT-001953, Generic Guidelines for ISDN Terminal Equipment On Basic Access Interfaces, chapter 5.2.5.8. - Bellcore SR-NWT-002343, ISDN Primary Rate Interface Generic Guidelines for Customer Premises Equipment, chapter 8.2.5.8. - ITU-T Q.931, Appendix I. - ITU-T X.25, CAUSE and DIAGNOSTIC field values. - German Telekom FTZ 1TR6, chapter 3.2.3.4.4.4." ::= { callHistoryEntry 6 }callHistoryDisconnectText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII text describing the reason for call termination. This object exists because it would be impossible for a management station to store all possible cause values for all types of interfaces. It should be used only if a management station is unable to decode the value of dialCtlPeerStatsLastDisconnectCause." ::= { callHistoryEntry 7 }callHistoryConnectTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTIONRoeck Standards Track [Page 26]RFC 2128 Dial Control MIB March 1997 "The value of sysUpTime when the call was connected." ::= { callHistoryEntry 8 }callHistoryDisconnectTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the call was disconnected." ::= { callHistoryEntry 9 }callHistoryCallOrigin OBJECT-TYPE SYNTAX INTEGER { originate(1),
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -