; Number of registers using Asynchronous Clear ; 0     ;
; Number of registers using Asynchronous Load  ; 0     ;
; Number of registers using Clock Enable       ; 0     ;
; Number of registers using Preset             ; 0     ;
+----------------------------------------------+-------+


+--------------------------------------------------+
; Inverted Register Statistics                     ;
+----------------------------------------+---------+
; Inverted Register                      ; Fan out ;
+----------------------------------------+---------+
; Sev_Seg_Led_Sel_n[0]~reg0              ; 5       ;
; Sev_Seg_Led_Sel_n[1]~reg0              ; 3       ;
; Sev_Seg_Led_Sel_n[2]~reg0              ; 3       ;
; Sev_Seg_Led_Sel_n[3]~reg0              ; 3       ;
; Total number of inverted registers = 4 ;         ;
+----------------------------------------+---------+


+-------------------------------+
; Analysis & Synthesis Messages ;
+-------------------------------+
Info: *******************************************************************
Info: Running Quartus II Analysis & Synthesis
    Info: Version 8.0 Build 215 05/29/2008 SJ Full Version
    Info: Processing started: Wed Jul 02 22:08:03 2008
Info: Command: quartus_map --read_settings_files=on --write_settings_files=off Segment2 -c Segment2
Warning: Using design file Segment2.v, which is not specified as a design file for the current project, but contains definitions for 1 design units and 1 entities in project
    Info: Found entity 1: Segment2
Info: Elaborating entity "Segment2" for the top level hierarchy
Warning (14130): Reduced register "Sev_Seg_Led_Data_n[7]~reg0" with stuck data_in port to stuck value GND
Warning (14130): Reduced register "Sev_Seg_Led_Data_n[1]~reg0" with stuck data_in port to stuck value GND
Info: Duplicate registers merged to single register
    Info (13350): Duplicate register "Sev_Seg_Led_Data_n[0]~reg0" merged to single register "Sev_Seg_Led_Data_n[3]~reg0"
Info: State machine "|Segment2|Disp_Sel" contains 16 states
Info: Selected Auto state machine encoding method for state machine "|Segment2|Disp_Sel"
Info: Encoding result for state machine "|Segment2|Disp_Sel"
    Info: Completed encoding using 16 state bits
        Info: Encoded state bit "Disp_Sel.1111"
        Info: Encoded state bit "Disp_Sel.1110"
        Info: Encoded state bit "Disp_Sel.1101"
        Info: Encoded state bit "Disp_Sel.1100"
        Info: Encoded state bit "Disp_Sel.1011"
        Info: Encoded state bit "Disp_Sel.1010"
        Info: Encoded state bit "Disp_Sel.1001"
        Info: Encoded state bit "Disp_Sel.1000"
        Info: Encoded state bit "Disp_Sel.0111"
        Info: Encoded state bit "Disp_Sel.0110"
        Info: Encoded state bit "Disp_Sel.0101"
        Info: Encoded state bit "Disp_Sel.0100"
        Info: Encoded state bit "Disp_Sel.0011"
        Info: Encoded state bit "Disp_Sel.0010"
        Info: Encoded state bit "Disp_Sel.0001"
        Info: Encoded state bit "Disp_Sel.0000"
    Info: State "|Segment2|Disp_Sel.0000" uses code string "0000000000000000"
    Info: State "|Segment2|Disp_Sel.0001" uses code string "0000000000000011"
    Info: State "|Segment2|Disp_Sel.0010" uses code string "0000000000000101"
    Info: State "|Segment2|Disp_Sel.0011" uses code string "0000000000001001"
    Info: State "|Segment2|Disp_Sel.0100" uses code string "0000000000010001"
    Info: State "|Segment2|Disp_Sel.0101" uses code string "0000000000100001"
    Info: State "|Segment2|Disp_Sel.0110" uses code string "0000000001000001"
    Info: State "|Segment2|Disp_Sel.0111" uses code string "0000000010000001"
    Info: State "|Segment2|Disp_Sel.1000" uses code string "0000000100000001"
    Info: State "|Segment2|Disp_Sel.1001" uses code string "0000001000000001"
    Info: State "|Segment2|Disp_Sel.1010" uses code string "0000010000000001"
    Info: State "|Segment2|Disp_Sel.1011" uses code string "0000100000000001"
    Info: State "|Segment2|Disp_Sel.1100" uses code string "0001000000000001"
    Info: State "|Segment2|Disp_Sel.1101" uses code string "0010000000000001"
    Info: State "|Segment2|Disp_Sel.1110" uses code string "0100000000000001"
    Info: State "|Segment2|Disp_Sel.1111" uses code string "1000000000000001"
Info: Duplicate registers merged to single register
    Info (13360): Duplicate register "Disp_Sel.0001" merged to single register "Sev_Seg_Led_Sel_n[0]~reg0", power-up level changed
    Info (13360): Duplicate register "Disp_Sel.0010" merged to single register "Sev_Seg_Led_Sel_n[1]~reg0", power-up level changed
    Info (13360): Duplicate register "Disp_Sel.0011" merged to single register "Sev_Seg_Led_Sel_n[2]~reg0", power-up level changed
    Info (13360): Duplicate register "Disp_Sel.0100" merged to single register "Sev_Seg_Led_Sel_n[3]~reg0", power-up level changed
Warning: Output pins are stuck at VCC or GND
    Warning (13410): Pin "Sev_Seg_Led_Data_n[1]" is stuck at GND
    Warning (13410): Pin "Sev_Seg_Led_Data_n[7]" is stuck at GND
    Warning (13410): Pin "Led_En_n" is stuck at VCC
    Warning (13410): Pin "Buzz" is stuck at GND
Info: 30 registers lost all their fanouts during netlist optimizations. The first 30 are displayed below.
    Info: Register "Disp_Sel.0110" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1000" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1011" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.0101" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.0111" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1001" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1010" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1100" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1101" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1110" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel.1111" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel~7" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel~8" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel~9" lost all its fanouts during netlist optimizations.
    Info: Register "Disp_Sel~10" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[15]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[16]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[17]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[18]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[19]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[20]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[21]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[22]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[23]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[24]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[25]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[26]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[27]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[28]" lost all its fanouts during netlist optimizations.
    Info: Register "Cout[29]" lost all its fanouts during netlist optimizations.
Info: Implemented 40 device resources after synthesis - the final resource count might be different
    Info: Implemented 1 input pins
    Info: Implemented 14 output pins
    Info: Implemented 25 logic cells
Info: Quartus II Analysis & Synthesis was successful. 0 errors, 8 warnings
    Info: Peak virtual memory: 156 megabytes
    Info: Processing ended: Wed Jul 02 22:08:06 2008
    Info: Elapsed time: 00:00:03
    Info: Total CPU time (on all processors): 00:00:01