📄 thermospeedhc.m
字号:
function T = thermospeedHC(Ea,Estd,walkers,dEtgt,v,e,T,t,P)
% Heat capacity thermospeed temperature update method supplied with SA Tools.
% Copyright (c) 2002, by Richard Frost and Frost Concepts.
% See http://www.frostconcepts.com/software for information on SA Tools.
%
% T = thermospeedHC(Ea,Estd,walkers,dEtgt,v,e,T,t,P) ;
%
% Ea = (not used) average energy.
% Estd = standard deviation of energies
% walkers = (not used) number of walkers
% dEtgt = difference between present and previous target mean energy
% v = (not used) thermodynamic speed.
% e = (not used) estimate of relaxation time.
% T = current temperature.
% t = (not used) temperature step #.
% P = (not used) constant
%
% Temperature will not change if
% 1. Estd is zero
% 2. Input T is negative, zero, or infinite
% 3. The calculated temperature would be negative or infinite
%
if (Estd > 0) & (T > 0) & (T ~= Inf)
B = 1/T ; % use inverse temperature for stability
dB = -dEtgt / (Estd*Estd) ;
B = B + dB ;
if B > 0 % only change if stable
T = 1 / B ;
end
end