⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 plotsd.1

📁 speech signal process tools
💻 1
字号:
.\"@(#)plotsd.1	1.6 12/17/86.TH PLOTSD 1-SPS 12/17/86.ds ]W "\fI\s+4\ze\h'0.05'e\s-4\v'-0.4m'\fP\(*p\v'0.4m'\ Entropic Processing, Inc..SH NAMEplotsd - plot sampled data.SH SYNOPSIS.B plotsd[.BI \-{ps} " range"] [.BI \-y " range"] [.BI \-Y " range"] [.BI \-m " maxpnts"].br[.BI \-t " text"].I file.SH DESCRIPTION.PP.I plotsdplots a portion of an SPS sampled data file .I file.  Actually, it generatescommands that are suitable for .IR plotas "(1) or".IR stou "(1)."If the \fB\-p\fP option is omitted, then the \fIrange\fP is computedfrom the parameter and common files, otherwise the the entire contentsof .I file is used as the default range.  .PP.I Plotsdfinds the maximum and  minimum values in the specified range and computes appropriate scales for the .I x\-and .IR y\- axes.These automatic values can be overriden by the .B \-yor.B \-Y options.  .PPWhen .IR stou "(1) and".IR mcd (1)are used to plot on the Masscomp screen (see EXAMPLES, below), the plotswill take a long time if every point is plotted.  For this reason, .I plotsdplots a maximum of approximately 3000 points across the range specified by the user (intermediate points are skipped).  This behaviorcan be changed by means of the .B \-m option.   .PP.I Plotsdwill run faster if the .B \-Yoption is used, especially in the case of large files.  .SH OPTIONS.PPThe following options are supported:.TP.BI \-p " first:last".TP.BI \-p " first:+incrDetermines the range of points to be plotted.  In the first form, apair of unsigned integers gives the first and last points of the range.  If .I firstis omitted, 1 is used.  If .I last is omitted, the last point in the file is used.  The second form isequivalent to the first with .I "last = first + incr"..TP.BI \-s " range"Select a range of points to be plotted in seconds. For compatibility withDSC LISTEN, the beginning of the file is 0..TP.BI \-y " low:high"Specifies approximate lower and upper limits for the .IR y- axis.The values are adjusted by .I plotsdin an attempt to make an esthetically pleasing plot.  .TP.BI \-Y " low:high"Specifies exact lower and upper limits for the .IR y- axis..TP.BI \-m " maxpnts\fR [3000]\fP"Specifies that .I plotsdplot up to an approximate maximum of .I maxpnts points.  If the total number of points in the .I rangeexceeds .I maxpnts,points are skipped evenly throughout.  .TP.BI \-t " text"A line of text to be printed below the plot.  Up to ten.B \-toptions may be specified; they are printed as text lines in order below theplot..SH EXAMPLES.TP.BI "plotsd " <options> " | stou | mcd"plots on the Masscomp display..TP.BI "plotsd " <options> " | plotas | tpen | ipr -Ltektronix"plots on the Imagen.TP.BI "plotsd " <options> " | stou | tek | ipr -Ltektronix"also plots on the Imagen, but a scaling factor may need to be specified for tek. .TP.BI "plotsd " <options> " | plotas | tpen"plots on a Tektronix terminal.TP.BI "plotsd " <options> " | stou | tek"also plots on a Tektronix terminal. 	.SH "SPS COMMON"The following items are read from the SPS Common file.  The values forstart and nan are not used if a range is specified on the command line orif the input file is not the same file identified in theCommon file by the "filename" symbol. .IP.I "start - integer".IPThis is the starting point in the sampled data file to beginplotting. If it is zero, the beginning of the file is used..sp.I "nan - integer".IPThis is the number of points (starting at .IR start )to plot.If it is zero, the entire file is used as the default.  .sp.I "filename - string".IPThis is the name of the file to be displayed if \fIfile\fP is omittedfrom the command line..PPThe following items are written into the SPS Common file:.IP.I "start - integer".IPThe left point in the range selected..sp.I "nan - integer".IPThe number of points in the selected range..sp.I "beginplot - integer".IPThe origin of the graph (x-coordinate)..sp.I "endplot - integer".IPThe end point of the graph (x-coordinate)..sp.I "prog - string".IPThis is the name of the program (\fIplotsd\fP in this case)..sp.I "filename - string".IPThis is the name of the file to be displayed.The program terminates if \fIfilename\fP does not exist when \fIfile\fPis not specified on the command line..SH "SPS HEADERS".PP.I Plotsdreads the following fields from the SD file header:.I common.type,.I common.ndrec,.SH DIAGNOSTICS.PP.I Plotsdcomplains if there is no such file, or if the file is not a sampled data file..SH EXPECTED CHANGES.PPMany more options may be added..SH SEE ALSO.IR plotpit (1\-SPS), .IR plotsdm (1\-SPS), .IR plotsdi (1\-SPS), .IR mlplot (1\-SPS), .IR genplot (1\-SPS), .IR stou "(1),\ " .IR plotas "(1),\ ".IR mcd "(1),\ ".IR tek "(1).\ ".SH AUTHOR.PP.nfJoseph T. Buck, Entropic Processing, Inc.Adapted from a program by Shankar Narayan.Converted by Rod Johnson to read new SPS format.Modified for SPS Common by Ajaipal S. Virdy.Modified for -y, -Y, and -m by John ShoreManual page revised by John Shore.fi

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -