<HTML
><HEAD
><TITLE
>Configuring eCos</TITLE
><meta name="MSSmartTagsPreventParsing" content="TRUE">
<META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
"><LINK
REL="HOME"
TITLE="eCos Reference Manual"
HREF="ecos-ref.html"><LINK
REL="UP"
TITLE="SNMP for eCos"
HREF="net-snmp-ecos-port.html"><LINK
REL="PREVIOUS"
TITLE="Starting the SNMP Agent"
HREF="net-snmp-starting-the-snmp-agent.html"><LINK
REL="NEXT"
TITLE="Test cases"
HREF="net-snmp-test-cases.html"></HEAD
><BODY
CLASS="SECT1"
BGCOLOR="#FFFFFF"
TEXT="#000000"
LINK="#0000FF"
VLINK="#840084"
ALINK="#0000FF"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>eCos Reference Manual</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="net-snmp-starting-the-snmp-agent.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
>Chapter 47. SNMP for <SPAN
CLASS="emphasis"
><I
CLASS="EMPHASIS"
>eCos</I
></SPAN
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="net-snmp-test-cases.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><DIV
CLASS="SECT1"
><H1
CLASS="SECT1"
><A
NAME="NET-SNMP-CONFIGURING-ECOS">Configuring eCos</H1
><P
>To use the SNMP agent, the SNMP library and agent packages must
be included in your configuration. In addition, at this point, the SNMP
stack only works with the OpenBSD-based TCP/IP stack, not the FreeBSD-based
stack. The "old_net" template can be used as a starting point for using
the OpenBSD-based TCP/IP stack, for example:
<TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="SCREEN"
>$ <TT
CLASS="USERINPUT"
><B
>ecosconfig new mytarget old_net</B
></TT
></PRE
></TD
></TR
></TABLE
>
or you can add the various required packages to an existing configuration with:
<TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="SCREEN"
>$ <TT
CLASS="USERINPUT"
><B
>ecosconfig add net openbsd_net eth_drivers</B
></TT
></PRE
></TD
></TR
></TABLE
></P
><P
>To incorporate the stack into your configuration select the SNMP library
and SNMP agent packages in the eCos Configuration Tool, or at the command
line type:
<TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="SCREEN"
>$ <TT
CLASS="USERINPUT"
><B
>ecosconfig add snmplib snmpagent</B
></TT
></PRE
></TD
></TR
></TABLE
></P
><P
>After adding the networking, common ethernet device drivers,
snmp library and snmp agent packages, there is no configuration
required. However there are a number of configuration options
that can be set such as some details for the System MIB, and
disabling SNMPv3 support (see below).</P
><P
>Starting the SNMP agent is not integrated into network
tests other than <TT
CLASS="FILENAME"
>snmpping</TT
> below, nor is it
started automatically in normal eCos startup -
it is up to the application to start the agent when it is ready,
at least after the network interfaces are both &#8216;up&#8217;.</P
><DIV
CLASS="SECT2"
><H2
CLASS="SECT2"
><A
NAME="NET-SNMP-VERSION-USAGE">Version usage (v1, v2 or v3)</H2
><P
>The default build supports all three versions of the SNMP protocol, but without
any dispatcher functionality (rfc 2571, section 3.1.1.2). This has the
following implications :</P
><P
> 1. There is no community authentication for v1 and v2c.</P
><P
>2. Security provided by v3 can be bypassed by using v1/v2c protocol.</P
><P
>To provide the dispatcher with rfc 2571 type functionality, it is required to
set up security models and access profiles. This can be provided in the normal
Unix style by writing the required configurations in <TT
CLASS="LITERAL"
>snmpd.conf</TT
> 
file. Application code may setup profiles in <TT
CLASS="LITERAL"
>snmpd.conf</TT
> and 
optionally set the environment variable <TT
CLASS="LITERAL"
>SNMPCONFPATH</TT
> to 
point to the file if it is not in the usual location. The whole concept works
in the usual way as with the standard UCD-SNMP distribution.</P
></DIV
><DIV
CLASS="SECT2"
><H2
CLASS="SECT2"
><A
NAME="TRAPS">Traps</H2
><P
>The support of the <TT
CLASS="LITERAL"
>trapsink</TT
> command in the
<A
HREF="net-snmp-agent-manpages-snmpd.conf.html"
>snmpd.conf</A
> file is not tested 
and there may be problems for it working as expected. Moreover, in systems that do not 
have filesystem support, there is no way to configure a trap-session in the
conventional way.</P
><P
>For reasons mentioned above, applications need to initialize their own trap
sessions and pass it the details of trap-sink. The following is a small sample
for initializing a v1 trap session :</P
><TABLE
BORDER="5"
BGCOLOR="#E0E0F0"
WIDTH="70%"
><TR
><TD
><PRE
CLASS="PROGRAMLISTING"
>typedef struct trap {
        unsigned char ip [4];
        unsigned int  port;
        unsigned char community [256];
}

trap            trapsink;
unsinged char   sink [16]; 

...
...

if (trapsink.ip != 0) {
        sprintf (sink, "%d.%d.%d.%d",
                 trapsink[0], trapsink[1], trapsink[2], trapsink[3]);
        if (create_trap_session (sink,
                trapsink.port,
                (char *)trapsink.community,
                SNMP_VERSION_1,
                SNMP_MSG_TRAP) == 0) {
                log_error ("Creation of trap session failed \n");
        }
}</PRE
></TD
></TR
></TABLE
></DIV
><DIV
CLASS="SECT2"
><H2
CLASS="SECT2"
><A
NAME="NET-SNMP-SNMPD-CONF"><TT
CLASS="LITERAL"
>snmpd.conf</TT
> file</H2
><P
>Using snmpd.conf requires the inclusion of one of the file-system packages
(eg. CYGPKG_RAMFS) and CYGPKG_FILEIO. With these two packages included, the
SNMP sub-system will read the snmpd.conf file from the location specified in
<TT
CLASS="LITERAL"
>SNMPCONFPATH</TT
>, or the standard builtin locations, and use
these profiles. Only the profiles specified in the <TT
CLASS="LITERAL"
>ACCESS-CONTROL</TT
>
section of <A
HREF="net-snmp-agent-manpages-snmpd.conf.html"
>snmpd.conf</A
> file have 
been tested and shown to work. Other profiles which have been implemented in 
<TT
CLASS="LITERAL"
>UCD-SNMP-4.1.2</TT
>'s <TT
CLASS="LITERAL"
>snmpd.conf</TT
> may not work
because the sole purpose of adding support for the snmpd.conf file has been to
set up <TT
CLASS="LITERAL"
>ACCESS-CONTROL</TT
> models.</P
><P
>At startup, the SNMP module tries to look for file <TT
CLASS="FILENAME"
>snmp.conf</TT
>. 
If this file is not available, the module successively looks for files
<TT
CLASS="FILENAME"
>snmpd.conf</TT
>, <TT
CLASS="FILENAME"
>snmp.local.conf</TT
> and 
<TT
CLASS="FILENAME"
>snmpd.local.conf</TT
> at the locations pointed to by <TT
CLASS="LITERAL"
>SNMPCONFPATH</TT
> environment variable. In case <TT
CLASS="LITERAL"
>SNMPCONFPATH</TT
> is not defined, the search sequence is carried out in default directories.
The default directories are :<TT
CLASS="FILENAME"
>/usr/share/snmp</TT
>, <TT
CLASS="FILENAME"
>/usr/local/share/snmp</TT
> and <TT
CLASS="FILENAME"
>$(HOME)/.snmp</TT
>.
The configurations read from these files are used to control both, SNMP 
applications and the SNMP agent; in the usual UNIX fashion.</P
><P
>The inclusion of snmpd.conf support is enabled by default when suitable 
filesystems and FILEIO packages are active.</P
></DIV
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="net-snmp-starting-the-snmp-agent.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="ecos-ref.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="net-snmp-test-cases.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>Starting the SNMP Agent</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="net-snmp-ecos-port.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Test cases</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -