c974007.a

来自「linux下编程用 编译软件」· A 代码 · 共 206 行

A
206
字号
-- C974007.A----                             Grant of Unlimited Rights----     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained --     unlimited rights in the software and documentation contained herein.--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making --     this public release, the Government intends to confer upon all --     recipients unlimited rights  equal to those held by the Government.  --     These rights include rights to use, duplicate, release or disclose the --     released technical data and computer software in whole or in part, in --     any manner and for any purpose whatsoever, and to have or permit others --     to do so.----                                    DISCLAIMER----     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED --     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE --     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A--     PARTICULAR PURPOSE OF SAID MATERIAL.--*---- OBJECTIVE:--      Check that the sequence of statements of the triggering alternative--      of an asynchronous select statement is not executed if the triggering--      statement is a protected entry call, and the entry is not accepted--      before the abortable part completes. Check that execution continues--      immediately following the asynchronous select.---- TEST DESCRIPTION:--      Declare a main procedure containing an asynchronous select with a--      protected entry call as triggering statement. Declare a protected--      procedure which sets the protected entry's barrier true. Ensure--      that the entry call is never accepted by not calling the protected--      procedure; the barrier remains false, and the entry call from--      asynchronous select is queued. Since the abortable part will complete--      before the entry is accepted, the sequence of statements of the--      triggering alternative is never executed.------ CHANGE HISTORY:--      06 Dec 94   SAIC    ACVC 2.0----!package C974007_0 is  -- Automated teller machine abstraction.   -- Flags for testing purposes:   --    Abortable_Part_Executed       : Boolean := False;   Perform_Transaction_Executed  : Boolean := False;   Triggering_Statement_Executed : Boolean := False;   type Key_Enum is (None, Cancel, Deposit, Withdraw);   type Card_Number_Type is private;   type Card_PIN_Type    is private;   type ATM_Card_Type    is private;   Transaction_Canceled : exception;   protected type ATM_Keyboard_Protected is      entry Cancel_Pressed;      procedure Read_Key;   private      Last_Key_Pressed : Key_Enum := None;   end ATM_Keyboard_Protected;   procedure Read_Card (Card : in out ATM_Card_Type);   procedure Validate_Card (Card : in ATM_Card_Type);   procedure Perform_Transaction (Card : in ATM_Card_Type);private   type Card_Number_Type is range   1 .. 9999;   type Card_PIN_Type    is range 100 ..  999;   type ATM_Card_Type is record      Number : Card_Number_Type;      PIN    : Card_PIN_Type;   end record;end C974007_0;     --==================================================================--with Report;package body C974007_0 is   protected body ATM_Keyboard_Protected is      -- Barrier is false for the live of the test      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is        begin                                                           Triggering_Statement_Executed  := true;   -- Test has failed      -- (Note: cannot call Report.Failed in the protected entry body]      end Cancel_Pressed;      procedure Read_Key is                                     -- Never      begin                                                     -- called.         -- Simulate a procedure which reads user keyboard input, and         -- which is called by some interrupt handler.         Last_Key_Pressed := Cancel;      end Read_Key;   end ATM_Keyboard_Protected;   procedure Read_Card (Card : in out ATM_Card_Type) is   begin      Card.Number := 9999;      Card.PIN    := 111;   end Read_Card;   procedure Validate_Card (Card : in ATM_Card_Type) is   begin      Abortable_Part_Executed := True;   end Validate_Card;   procedure Perform_Transaction (Card : in ATM_Card_Type) is   begin      Perform_Transaction_Executed := True;   end Perform_Transaction;end C974007_0;     --==================================================================--with Report;with C974007_0;  -- Automated teller machine abstraction.use  C974007_0;procedure C974007 is   Card_Data : ATM_Card_Type;begin   Report.Test ("C974007", "ATC: trigger is protected entry call" &                              " and abortable part completes first");   Read_Card (Card_Data);   declare      Keyboard : C974007_0.ATM_Keyboard_Protected;   begin      --                                    --      -- Asynchronous select is tested here --      --                                    --      select         Keyboard.Cancel_Pressed;        -- Barrier is never set true, so                                         -- entry call is queued and never                                         -- accepted.         raise Transaction_Canceled;     -- Should not be executed.      then abort         Validate_Card (Card_Data);      -- This call completes before                                         -- Keyboard.Cancel_Pressed can be                                         -- accepted.      end select;      Perform_Transaction (Card_Data);   -- Execution proceeds here after                                         -- Validate_Card completes.   exception      when Transaction_Canceled =>         Report.Failed ("Triggering alternative sequence of statements " &                        "executed");   end;         if Triggering_Statement_Executed  then      Report.Failed ("Triggering statement was executed");   end if;   if not Abortable_Part_Executed then      Report.Failed ("Abortable part not executed");   end if;   if not Perform_Transaction_Executed then      Report.Failed ("Statements following asynchronous select not " &                     "executed");   end if;   Report.Result;end C974007;

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?