📄 can in automation (cia) - canopen product guide.htm
字号:
href="http://www.can-cia.org/products/pg2005/html/index-485.htm"><SPAN>⇒ </SPAN>CO40xx
family of controllers</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-486.htm"><SPAN>⇒ </SPAN>COM-C-COM/C-COS
slave interface board family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-487.htm"><SPAN>⇒ </SPAN>CompactModule
I/O module family (truck, off-highway, railway)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-488.htm"><SPAN>⇒ </SPAN>CrossFire
I/O module and controller (truck, off-highway)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-489.htm"><SPAN>⇒ </SPAN>DDC
712 I/O module family (railway)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-490.htm"><SPAN>⇒ </SPAN>DI32,
DO32 and DIO32 I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-491.htm"><SPAN>⇒ </SPAN>DICO-708EX
controller</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-492.htm"><SPAN>⇒ </SPAN>DICO-908
I/O module family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-493.htm"><SPAN>⇒ </SPAN>Digital
Strain Card (Dcell/DSC)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-494.htm"><SPAN>⇒ </SPAN>E.FBM
I/O modules and controller family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-495.htm"><SPAN>⇒ </SPAN>E2C
20 I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-496.htm"><SPAN>⇒ </SPAN>EA515
digital and analog I/O module family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-497.htm"><SPAN>⇒ </SPAN>Easy
family of controllers</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-498.htm"><SPAN>⇒ </SPAN>Epec
IP67 Power Switch Module I/O modules (off-highway, truck)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-499.htm"><SPAN>⇒ </SPAN>ESX-DIOS/ESX-DIOM
I/O module family (truck, off-highway)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-500.htm"><SPAN>⇒ </SPAN>EX120/121/122-SPR1-B
I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-501.htm"><SPAN>⇒ </SPAN>ExC5x
controller</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-502.htm"><SPAN>⇒ </SPAN>FC5101/
FC5102 interface board family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-503.htm"><SPAN>⇒ </SPAN>Fieldbus
Box I/O module family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-504.htm"><SPAN>⇒ </SPAN>FLS
CO M12 DI 8 M12 Fieldline CANopen I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-505.htm"><SPAN>⇒ </SPAN>FLS
CO M12 DI 16 M12 Fieldline CANopen I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-506.htm"><SPAN>⇒ </SPAN>FLS
CO M12 DIO 4/4 M12-2A Fieldline CANopen I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-507.htm"><SPAN>⇒ </SPAN>FLS
CO M12 DIO 8/8 M12 Fieldline CANopen I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-508.htm"><SPAN>⇒ </SPAN>FLS
CO M12 DO 8 M12-2A Fieldline CANopen I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-509.htm"><SPAN>⇒ </SPAN>MVK-C
I/O module family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-510.htm"><SPAN>⇒ </SPAN>PC
CX1000 controller family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-511.htm"><SPAN>⇒ </SPAN>PLCmodule-C14
controller</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-512.htm"><SPAN>⇒ </SPAN>PowerCAN
PCI interface board</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-513.htm"><SPAN>⇒ </SPAN>Quad
Remote 祍tepper actuator</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-514.htm"><SPAN>⇒ </SPAN>R360
SmartModule I/O module family (truck, off-highway, railway)</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-515.htm"><SPAN>⇒ </SPAN>RBXM/RBXE/RBXC/RMC
motion controllers</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-516.htm"><SPAN>⇒ </SPAN>Remote
IO RDIO16/16 I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-517.htm"><SPAN>⇒ </SPAN>RIO-PS-24I/16O,
RIO-24I/16O, RIO-48I/32O I/O modules</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-518.htm"><SPAN>⇒ </SPAN>Sick
barcode scanner family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-519.htm"><SPAN>⇒ </SPAN>Sigmadue
I/O module family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-520.htm"><SPAN>⇒ </SPAN>Syslogic
Industrial PC family</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-521.htm"><SPAN>⇒ </SPAN>Sys
Tec CANopen Starter Kit</A>
<LI class=""><A
href="http://www.can-cia.org/products/pg2005/html/index-522.htm"><SPAN>⇒ </SPAN>Vipa
342-1CA70 System 300 PLC controller family</A>
<LI class=last><A
href="http://www.can-cia.org/products/pg2005/html/index-523.htm"><SPAN>⇒ </SPAN>X67BC4321
I/O module and controller</A> </LI></UL>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-7.htm"><SPAN>⇒ </SPAN>CiA
402</A>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-8.htm"><SPAN>⇒ </SPAN>CiA
404</A>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-9.htm"><SPAN>⇒ </SPAN>CiA
405</A>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-10.htm"><SPAN>⇒ </SPAN>CiA
406</A>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-11.htm"><SPAN>⇒ </SPAN>CiA
410</A>
<LI class=""><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-12.htm"><SPAN>⇒ </SPAN>CiA
417</A>
<LI class=last><A class=head
href="http://www.can-cia.org/products/pg2005/html/index-13.htm"><SPAN>⇒ </SPAN>CiA
420</A> </LI></UL></DIV>
<DIV class=content>
<H3>CANopen device profile for generic I/O modules</H3>
<P>Published at end of 1999, CiA DS 401 device profile version 2.0 specifies the
communication behavior of Process Data Objects (PDO) and defines the default PDO
mapping as well. Devices compliant to this specification are partly
interchangeable. Sophisticated configuration options allow adaptability to very
different applications.<BR><BR>Input/output devices may have analog and digital
ports for sensors and actuators. They are available in different form factors
and housings. Some of them are modularly expandable. The device profile defines
the communication, configuration, and application objects but also the default
behavior after power-on and application reset.<BR><BR>In case of serious
communication (e.g. message lost) or device failure (e.g. short circuit at
output) the I/O device switches by default into 慞re-operational
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -