log.m2pa

来自「No7信令,我需要交换类似的代码, 请店长审核,谢谢了,急着交换,谢谢」· M2PA 代码 · 共 1,152 行 · 第 1/5 页

M2PA
1,152
字号
              :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                                      :set emergency                                  <-----------------  PROVING-EMERGENCY                                     !                                                                   !  T4(Pn)                                                           !                                                             <-----------------  IN-SERVICE                                        check timeout     T4  ( 300<= 494<=   700)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.21Link State Control - Expected signal units/ordersBoth ends set emergency.Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :set emergency                                                      :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-EMERGENCY            PROVING-EMERGENCY  ----------------->                                                        !                                                                   !  T4(Pe)                                                           !                                                             <-----------------  IN-SERVICE                                        check timeout     T4  ( 300<= 495<=   700)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.22Link State Control - Expected signal units/ordersIndividual end sets emergencyPrecondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                      :set emerg                                                              :start                                                           ALIGNMENT  ----------------->                                                                      :start                                          <-----------------  ALIGNMENT                    PROVING-EMERGENCY  ----------------->                                                  <-----------------  PROVING-NORMAL                                        !                                                                   !  T4(Pe)                                                           !                                                             <-----------------  IN-SERVICE                                        check timeout     T4  ( 300<= 498<=   700)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.23Link State Control - Expected signal units/ordersSet emergency during normal provingPrecondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                                      :set emergency                                  <-----------------  PROVING-EMERGENCY                                     !                                                                   !  T4(Pe)                                                           !                                                             <-----------------  IN-SERVICE                                        check timeout     T4  ( 300<= 494<=   700)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.24Link State Control - Expected signal units/ordersNo SIO send during emergency alignmentPrecondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :set emergency                                                      :start                                          <-----------------  ALIGNMENT                               :start                                                   PROVING-EMERGENCY  ----------------->                                                  <-----------------  PROVING-EMERGENCY                                     !                                                                   !  T4(Pe)                                                           !                                                             <-----------------  IN-SERVICE                                        check timeout     T4  ( 300<= 500<=   700)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.25Link State Control - Expected signal units/ordersDeactivation duing intial alignmentPrecondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :start                                          <-----------------  ALIGNMENT                                       -----timeout------                                                                      :stop                                           <-----------------  OUT-OF-SERVICE                                                                                                      =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                                                                      Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.26Link State Control - Expected signal units/ordersDeactivation during aligned statePrecondition                                                                                                                                                          

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?