⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 log.m2pa

📁 No7信令,我需要交换类似的代码, 请店长审核,谢谢了,急着交换,谢谢
💻 M2PA
📖 第 1 页 / 共 5 页
字号:
                                             !rpo                                                                                                                =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.10Link State Control - Expected signal units/ordersNormal alignment with PO set and clearedPrecondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :set lpo                                                            :clear lpo                                                          :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                  <-----------------  IN-SERVICE                          IN-SERVICE  ----------------->                                                                      !in service                                                                                                         =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.11Link State Control - Expected signal units/ordersSet RPO when "Aligned not ready"Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                        :set lpo                                                                                          :set lpo                                                            :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                  <-----------------  PROCESSOR-OUTAGE              PROCESSOR-OUTAGE  ----------------->                                                                      !rpo                                                                                                                =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                           <-----------------  OUT-OF-SERVICE                                                                             Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.12(a)Link State Control - Expected signal units/ordersSIOS received when "Aligned not ready"Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :set lpo                                                            :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                  <-----------------  PROCESSOR-OUTAGE                         :stop                                                      OUT-OF-SERVICE  ----------------->                                                  <-----------------  OUT-OF-SERVICE                                                      !out of service(SIOS)                                                                                             =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                                                                      Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.12(b)Link State Control - Expected signal units/ordersSIOS received when "Aligned not ready"Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                        :set lpo                                                              :start                                                                                          :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                  <-----------------  IN-SERVICE                                                          :stop                               IN-SERVICE  ----------------->                                                  <-----------------  OUT-OF-SERVICE                                                                                                      =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                                                                      Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.13Link State Control - Expected signal units/ordersSIO received when "Aligned not ready"Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :set lpo                                                            :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                  PROVING-NORMAL  ----------------->                                                  <-----------------  PROCESSOR-OUTAGE                     ALIGNMENT  ----------------->                                                  <-----------------  OUT-OF-SERVICE                                                      !out of service(SIO)         OUT-OF-SERVICE  ----------------->                                                                                                                      =====SUCCESS======                                                                                             Postcondition                                                                                                                                                                        :stop                                                                                      Done                                                                **************** SUCCESS - test case successful.********Q.781/Test 1.14Link State Control - Expected signal units/ordersSet and clear LPO when "Initial alignment"Precondition                                                                                                                                                                         :connect                                                            :power on                                                                                  Test Case                                                                                                                                                        <-----------------  OUT-OF-SERVICE                       :power on                                                      OUT-OF-SERVICE  ----------------->                                                                      :start                                          <-----------------  ALIGNMENT                               :start                                                           ALIGNMENT  ----------------->                                                  <-----------------  PROVING-NORMAL                                                      :set lpo                        PROVING-NORMAL  ----------------->                         

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -