📄 log.m2pa
字号:
Q.781/Test 1.1(a)Link State Control - Expected signal units/ordersInitialization (Power-up)Precondition :connect Test Case :power on OUT-OF-SERVICE -----------------> :power on <----------------- OUT-OF-SERVICE =====SUCCESS====== Postcondition :stop Done **************** SUCCESS - test case successful.********Q.781/Test 1.1(b)Link State Control - Expected signal units/ordersInitialization (Power-up)Precondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> =====SUCCESS====== Postcondition :stop Done **************** SUCCESS - test case successful.********Q.781/Test 1.2Link State Control - Expected signal units/ordersTimer T2Precondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> :start <----------------- ALIGNMENT ! ! T2 ! <----------------- OUT-OF-SERVICE !out of service(AERM) check timeout T2 (4900<=5009<=150100) =====SUCCESS====== Postcondition :stop Done **************** SUCCESS - test case successful.********Q.781/Test 1.3Link State Control - Expected signal units/ordersTimer T3Precondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> :start <----------------- ALIGNMENT :start ALIGNMENT -----------------> <----------------- PROVING-NORMAL ! ! T3 ! <----------------- OUT-OF-SERVICE !out of service(AERM) check timeout T3 ( 900<= 995<= 1600) =====SUCCESS====== Postcondition :stop Done **************** SUCCESS - test case successful.********Q.781/Test 1.4Link State Control - Expected signal units/ordersTimer T1 & Timer T4 (Normal)Precondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> :start <----------------- ALIGNMENT :start ALIGNMENT -----------------> ! ! T4(Pn) ! <----------------- PROVING-NORMAL PROVING-NORMAL -----------------> <----------------- IN-SERVICE check timeout T4 (7400<=8014<= 9600) ! ! T1 ! <----------------- OUT-OF-SERVICE !out of service(T1) check timeout T1 (39900<=44989<= 50100) =====SUCCESS====== Postcondition :stop Done **************** SUCCESS - test case successful.********Q.781/Test 1.5(a)Link State Control - Expected signal units/ordersNormal alignment procedurePrecondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> :start <----------------- ALIGNMENT :start ALIGNMENT -----------------> <----------------- PROVING-NORMAL PROVING-NORMAL -----------------> <----------------- IN-SERVICE IN-SERVICE -----------------> !in service =====SUCCESS====== Postcondition :stop <----------------- OUT-OF-SERVICE Done **************** SUCCESS - test case successful.********Q.781/Test 1.5(b)Link State Control - Expected signal units/ordersNormal alignment procedurePrecondition :connect :power on Test Case <----------------- OUT-OF-SERVICE :power on OUT-OF-SERVICE -----------------> :start <----------------- ALIGNMENT :start ALIGNMENT -----------------> <----------------- PROVING-NORMAL PROVING-NORMAL -----------------> <----------------- IN-SERVICE IN-SERVICE -----------------> !in service
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -