📄 smvecdef10.m
字号:
% SYNCHRONOUS MACHINE PARAMETERS AND OPERATING POINT <smvecdef10.m>
clc,close all
disp(date)
% ------------------------ DATA --------------------------------------------
% Machine parameters (pu) :
Ra=.018;Ld=1.15;Lq=.75;Lal=0.15;
Rf=0.001; Lfl=0.2; Rkd=0.02; Lkdl=0.11; Rkq=0.04; Lkql=0.15;Lmd=Ld-Lal;
Lmq=Lq-Lal; H=4.0;Bm=1e-6; freq0=60.0;wo=2*pi*freq0 ;bet=0 ;
% Line parameters:
Rline=.0001; Lline=0.3;
% Initial state :
V=1.0 ; %bus voltage
Ef=1.0; %initial excitation voltage
Te0=0 ; %no load
n0=1 ; %initial speed
delta0=0 ; %initial phaseshift
% ----------------------------------------------------------------------------
disp(' MACHINE PARAMETERS in per unit: ')
disp(' Ra Ld Lq Lal Rline Lline')
disp([Ra Ld Lq Lal Rline Lline])
disp(' Rf Lfl Rkd Lkdl Rkq Lkql H ')
param1=[Rf Lfl Rkd Lkdl Rkq Lkql H];
disp(param1)
% INDUCTANCES
L=[Lal+Lmd 0 Lmd 0 Lmd
0 Lal+Lmq 0 Lmq 0
Lmd 0 Lmd+Lkdl 0 Lmd
0 Lmq 0 Lmq+Lkql 0
Lmd 0 Lmd 0 Lmd+Lfl];
L_1=inv(L);
% ----------------------------------------------------------------------------