⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 cpl2_sp.cir

📁 ngspice又一个电子CAD仿真软件代码.功能更全
💻 CIR
字号:
************ test circuit for transmission simulation **************m1     0     268    299     0  mn0p9  w = 18.0u l=1.0um2    299    267    748     0  mn0p9  w = 18.0u l=1.0um3     0     168    648     0  mn0p9  w = 18.0u l=0.9um4     1     268    748     1  mp1p0  w = 36.0u l=1.0um5     1     267    748     1  mp1p0  w = 36.0u l=1.0um6     1     168    648     1  mp1p0  w = 36.0u l=1.0u*CN648  648   0  0.025398e-12 CN651  651   0  0.007398e-12 CN748  748   0  0.025398e-12 CN751  751   0  0.009398e-12 CN299  299   0  0.005398e-12 ** Subcircuit test* test is a subcircuit that models a 2-conductor transmission line with* the following parameters: l=9.13e-09, c=2.75e-13, r=0.2, g=0,* inductive_coeff_of_coupling k=0.36144, inter-line capacitance cm=9e-14,* length=24. Derived parameters are: lm=3.29995e-09, ctot=3.65e-13.* * It is important to note that the model is a simplified one - the* following assumptions are made: 1. The self-inductance l, the* self-capacitance ctot (note: not c), the series resistance r and the* parallel capacitance g are the same for all lines, and 2. Each line* is coupled only to the two lines adjacent to it, with the same* coupling parameters cm and lm. The first assumption implies that edge* effects have to be neglected. The utility of these assumptions is* that they make the sL+R and sC+G matrices symmetric, tridiagonal and* Toeplitz, with useful consequences (see "Efficient Transient* Simulation of Lossy Interconnect", by J.S.  Roychowdhury and* D.O Pederson, Proc. DAC 91).* It may be noted that a symmetric two-conductor line is* represented accurately by this model.* Subckt node convention:* *            |--------------------------|*      1-----|                          |-----n+1*      2-----|                          |-----n+2*         :  |   n-wire multiconductor  |  :*         :  |          line            |  :*    n-1-----|(node 0=common gnd plane) |-----2n-1*      n-----|                          |-----2n*            |--------------------------|* Lossy line models.model mod1_test ltra rel=1.2 nocontrol r=0.2 l=5.83005279316e-09 g=0 c=4.55000000187e-13 len=24.model mod2_test ltra rel=1.2 nocontrol r=0.2 l=1.24299471863e-08 g=0 c=2.75000000373e-13 len=24* subcircuit m_test - modal transformation network for test.subckt m_test 1 2 3 4v1 5 0 0vv2 6 0 0vf1 0 3 v1 0.707106779721f2 0 3 v2 -0.707106782652f3 0 4 v1 0.707106781919f4 0 4 v2 0.707106780454e1 7 5 3 0 0.707106780454e2 1 7 4 0 0.707106782652e3 8 6 3 0 -0.707106781919e4 2 8 4 0 0.707106779721.ends m_test* Subckt test.subckt test 1 2 3 4x1 1 2 5 6 m_testo1 5 0 7 0 mod1_testo2 6 0 8 0 mod2_testx2 3 4 7 8 m_test.ends test*x1  648 748  651 751  test**vdd    1    0   DC  5.0VK   267    0   DC  5.0*VS1 168  0  PULSE (0 5 15.9N 0.2N 0.2N 15.8N 60N)VS2 268  0  PULSE (0 5 15.9N 0.2N 0.2N 15.8N 60N)*.TRAN 0.2N 47.9NS.PRINT TRAN v(648) v(651) v(751)*.model mn0p9 nmos  LEVEL=1 vto=0.8V kp=48u gamma=0.3 phi=0.55 lambda=0.0+                 PHI=0.55 LAMBDA=0.00 CGSO=0 CGDO=0 CGBO=0+                 CJ=0 CJSW=0 TOX=18000N NSUB=1E16 LD=0.0U.model mp1p0 pmos  LEVEL=1 vto=-0.8V kp=21u gamma=0.45 phi=0.61 lambda=0.0+                 PHI=0.61 LAMBDA=0.00 CGSO=0 CGDO=0 CGBO=0+                 CJ=0 CJSW=0 TOX=18000N NSUB=3E16 LD=0.0U.END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -