prjbas.bas

来自「电梯检测系统是对电梯性能进行检测的系统。是一个用来学习的程序。」· BAS 代码 · 共 1,871 行 · 第 1/5 页

BAS
1,871 行
字号
 '' FrmFuncTest.ButtonImg(4).Visible = False
  'FrmFuncTest.TitleLabel(11).Visible = False
  'FrmFuncTest.ButtonImg(9).Visible = False
  'FrmFuncTest.TitleLabel(18).Visible = False
  'FrmFuncTest.ButtonImg(10).Visible = False
  ''FrmFuncTest.TitleLabel(15).Visible = False
  'FrmFuncTest.ButtonImg(11).Visible = False
  'FrmFuncTest.TitleLabel(17).Visible = False
 ' FrmFuncTest.ButtonImg(12).Visible = False
 ' FrmFuncTest.TitleLabel(16).Visible = False
  FrmFuncTest.Frame2(0).Visible = False
  FrmFuncTest.Frame2(2).Visible = False
  FrmFuncTest.BackLabel(0).Visible = False
  FrmFuncTest.BackLabel(5).Visible = False

  EarthquakeControl = True
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Now begin fire service trip." & Chr(10) & Chr(13)
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Switching on the JBF." & Chr(10) & Chr(13)
  'set JBF to 1
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, JBFAddr, &HFF) Then
      CurSendSucc = True
      FrmFuncTest.toggle(9).Picture = LoadPicture(App.Path & "\button\switchon.gif")
      Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  TempFloor = CurFloor
  '0.5 second later,wait the signal work
  cTime = Timer
  Do Until Timer - cTime > 0.5
    DoEvents
  Loop
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Check whether the LEB lamp is lit." & Chr(10) & Chr(13)
  'check the LEB
  If SignalBitRight(LngVRetAryB, 72, 0) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LEB lamp did not be lit,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'check the lamp which mark whether the call be seviced
  'LC-1
  If SignalBitRight(LngVRetAryB, 73, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-1 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-2
  If SignalBitRight(LngVRetAryB, 74, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-2 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-3
  If SignalBitRight(LngVRetAryB, 75, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-3 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-U1
  If SignalBitRight(LngVRetAryB, 76, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-U1 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-U2
  If SignalBitRight(LngVRetAryB, 77, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-U2 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-D2
  If SignalBitRight(LngVRetAryB, 78, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-D2 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-D3
  If SignalBitRight(LngVRetAryB, 79, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-D3 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  
  'send two signal
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Now Send out at least two car call and landing call to check whether these calls will be cancelled." & Chr(10) & Chr(13)
  'set DC-3 to 1
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_3Addr, &HFF) Then
       CurSendSucc = True
       Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_3Addr, &H0) Then
       CurSendSucc = True
       Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  
  'set DC-D2 to 0
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_D2Addr, &HFF) Then
       CurSendSucc = True
       Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_D2Addr, &H0) Then
       CurSendSucc = True
       Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If

  'check the lamp which mark whether the call be seviced
  'LC-3
  If SignalBitRight(LngVRetAryB, 75, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-3 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'LC-D2
  If SignalBitRight(LngVRetAryB, 78, 1) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The LC-D2 was not cancelled,Earthquake Control failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  
  'wait the car stop
  Do Until NowMoveFx = "S"
    DoEvents
  Loop
  
  'check whether stop at the nearest floor
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Check whether stop at the nearest floor and keep the door opening 15-20 senconds then the door closed, at the same time the light will be switch off and 'leave car' light is lit. Then the car blocked." & Chr(10) & Chr(13)
  If Not (TempFloor = CurFloor) Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The car did not stop at the nearest floor,Earthquake Control trip failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'wait KET-O=1
  Do Until SignalBitRight(LngVRetAryB, 1, 1)
    DoEvents
  Loop
  'check whether keep opening 15-20 seconds
  cTime = Timer
  Do Until SignalBitRight(LngVRetAryB, 68, 1)
  DoEvents
  Loop
  If Timer >= cTime + 15 And Timer <= cTime + 20 Then
  Else
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The car did not keep opening 15-20 seconds,Earthquake Control trip failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'wait KET-S=1
  Do Until SignalBitRight(LngVRetAryB, 2, 1)
    DoEvents
  Loop
  'check LC=0 (light)
  If SignalBitRight(LngVRetAryB, 81, 0) Then 'LC
  Else
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Light did not switch off.Earthquake Control trip failed.Exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'send DT-O signal
  'set DT-O to 1
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DT_O, &HFF) Then
      CurSendSucc = True
      Exit Do
    End If
  Loop
  'set DT-O to 0
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DT_O, &H0) Then
      CurSendSucc = True
      Exit Do
    End If
  Loop
  'in ten seconds, the car door must be open
  cTime = Timer
  CurSendSucc = False
  Do Until Timer - cTime > 10
    If SignalBitRight(LngVRetAryB, 1, 1) Then
       CurSendSucc = True
       Exit Do
    End If
    DoEvents
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "in ten seconds, the car door did not be open." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  'check whether keep opening 15-20 seconds
  CurSendSucc = False
  cTime = Timer
  Do Until Timer > cTime + 20
    If SignalBitRight(LngVRetAryB, 68, 1) Then
      CurSendSucc = True
      Exit Do
    End If
    DoEvents
  Loop
  If CurSendSucc Then
  Else
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The car did not closed 15-20 seconds later,Earthquake Control trip failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Now reset the P mode signal. waiting 30 seconds, the system sends out a landing call.Make sure this landing had been served correctly." & Chr(10) & Chr(13)
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "reset the P mode , then press Yes button." & Chr(10) & Chr(13)
  YesCmdClick = False
  Do Until YesCmdClick
    DoEvents
  Loop
  If Not FuncTestPass Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "You cancel current test,Earthquake Control trip failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  
  '30 seconds later
  cTime = Timer
  Do Until Timer - cTime > 30
    DoEvents
  Loop
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Now send a landing call(DC-2)" & Chr(10) & Chr(13)
  'set DC-2 to 1
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_2Addr, &HFF) Then
      CurSendSucc = True
      Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  
  'set DC-2 to 0
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, DC_2Addr, &H0) Then
      CurSendSucc = True
      Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  
  Do Until NowMoveFx = "S"
    DoEvents
  Loop
  If CurFloor <> 2 Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "The car did not stop at correct floor,Earthquake Control trip failed.exit test." & Chr(10) & Chr(13)
    EarthquakeControl = False
    Exit Sub
  End If
  
  'set JBF to 0
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, JBFAddr, &H0) Then
      CurSendSucc = True
      FrmFuncTest.toggle(9).Picture = LoadPicture(App.Path & "\button\switchoff.gif")
      Exit Do
    End If
  Loop
  If Not CurSendSucc Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Handshake failed! Exit test!"
    EarthquakeControl = False
    Exit Function
  End If
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "If all are right, click Yes commandbutton,Or click No commandbutton." & Chr(10) & Chr(13)
  Do Until YesCmdClick
    DoEvents
  Loop
  If FuncTestPass Then
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Earthquake Control Trip Complished!" & Chr(10) + Chr(13)
    EarthquakeControl = True
  Else
    FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Earthquake Control Trip failed" & Chr(10) + Chr(13)
    EarthquakeControl = False
  End If
End Function

Public Function FireServiceTrip() As Boolean
  Dim cTime
  Dim CurSendSucc As Boolean
  
  'FrmFuncTest.ButtonImg(1).Visible = False
  'FrmFuncTest.TitleLabel(13).Visible = False
  'FrmFuncTest.ButtonImg(2).Visible = False
  'FrmFuncTest.TitleLabel(12).Visible = False
  'FrmFuncTest.ButtonImg(3).Visible = False
  'FrmFuncTest.TitleLabel(14).Visible = False
  'FrmFuncTest.ButtonImg(4).Visible = False
  'FrmFuncTest.TitleLabel(11).Visible = False
  'FrmFuncTest.ButtonImg(9).Visible = False
  'FrmFuncTest.TitleLabel(18).Visible = False
  'FrmFuncTest.ButtonImg(10).Visible = False
  'FrmFuncTest.TitleLabel(15).Visible = False
  'FrmFuncTest.ButtonImg(11).Visible = False
  'FrmFuncTest.TitleLabel(17).Visible = False
  'FrmFuncTest.ButtonImg(12).Visible = False
  'FrmFuncTest.TitleLabel(16).Visible = False
  FrmFuncTest.Frame2(0).Visible = False
  FrmFuncTest.Frame2(2).Visible = False
  FrmFuncTest.BackLabel(0).Visible = False
  FrmFuncTest.BackLabel(5).Visible = False
  
  FireServiceTrip = True
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Now begin fire service trip." & Chr(10) & Chr(13)
  FrmFuncTest.TestText.Text = FrmFuncTest.TestText.Text + "Switching on the JBF." & Chr(10) & Chr(13)
  'set JBF to 1
  CurSendSucc = False
  cTime = Timer
  Do Until Timer - cTime > 2
    If bolWritePlcB_05(iDeviceID, JBFAddr, &HFF) Then
      CurSendSucc = True
      FrmFuncTest.toggle(9).Picture = LoadPicture(App.Path & "\button\switchon.gif")
      Exit Do
    End If

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?