📄 rcs900.h

📁 在Unix平台下完成的电力系统广发使用的IEC103规约的程序
💻 H
📖 第 1 页 / 共 5 页
字号:
{134, 0,   0,   "有载重瓦斯信号"},
{135, 0,   0,   "非全相开入信号"},
{136, 0,   0,   "油温高信号"},
{139, 0,   0,   "压力突变信号"},
{140, 0,   0,   "绕组温高信号"},
{141, 0,   0,   "绕组过温信号"},
{142, 0,   0,   "本体油位异常信号"},
{143, 0,   0,   "有载油位异常信号"},
{144, 0,   0,   "非电量延时跳闸备用1信号"},
{145, 0,   0,   "非电量延时跳闸备用2信号"},
{146, 0,   0,   "轻瓦斯开入"},
{147, 0,   0,   "重瓦斯开入"},
{148, 0,   0,   "非电量备用1开入"},
{149, 0,   0,   "过励磁"},
{150, 0,   0,   "过负荷启动风扇"},
{152, 0,   0,   "高温"},
{153, 0,   0,   "温度越限Ⅰ段"},
{154, 0,   0,   "温度越限Ⅱ段"},
{155, 0,   0,   "低温"},
{156, 0,   0,   "风扇故障"},
{157, 0,   0,   "过负荷闭锁有载调压"},
{158, 0,   0,   "压力释放动作"},
{159, 0,   0,   "油位低"},
{160, 0,   0,   "风扇启动"},
{161, 0,   0,   "差流越限报警"},
{164, 0,   0,   "冷却器故障跳闸"},
{165, 0,   0,   "冷却器电源消失"},
{182, 0,   0,   "变压器过负荷"},
{184, 0,   0,   "冷却器故障"},
{187, 0,   0,   "遥控投入"},
{188, 0,   0,   "手合位置"},
{189, 0,   0,   "TWJ"},
{190, 0,   0,   "HWJ"},
{191, 0,   0,   "装置本机故障"},
{192, 0,   0,   "通信通道异常"},
{193, 0,   0,   "内部随机存储器异常"},
{194, 0,   0,   "数据(外部)随机存储器异常"},
{195, 0,   0,   "程序(只读)存储器出错"},
{196, 0,   0,   "EEPROM出错"},
{197, 0,   0,   "采样数据异常报警"},
{198, 0,   0,   "开关拒动"},
{199, 0,   0,   "液晶显示故障报警"},
{200, 0,   0,   "输出光电隔离击穿"},
{201, 0,   0,   "输出光电隔离无效"},
{202, 0,   0,   "光电隔离失电报警"},
{203, 0,   0,   "控制回路断线"},
{204, 0,   0,   "跳闸压力异常"},
{205, 0,   0,   "合闸压力异常"},
{206, 0,   0,   "电流互感器开路(CT断线)"},
{207, 0,   0,   "压力降低断路器禁止操作"},
{208, 0,   0,   "电流变化量长期启动报警"},
{209, 0,   0,   "运行方式位置异常报警"},
{210, 0,   0,   "TWJ报警"},
{211, 0,   0,   "装置内部通信故障"},
{212, 0,   0,   "跳闸报警"},
{213, 0,   0,   "重合闸报警"},
{214, 0,   0,   "长期启动报警"},
{215, 0,   0,   "低电压报警"},
{216, 0,   0,   "过电压报警"},
{217, 0,   0,   "零序过电压"},
{218, 0,   0,   "零序过电流"},
{219, 0,   0,   "#1母线接地"},
{220, 0,   0,   "#2母线接地"},
{221, 0,   0,   "系统频率异常"},
{222, 0,   0,   "定值校验出错"},
{223, 0,   0,   "修改定值位置告警"},
{224, 0,   0,   "定值变化(换区)"},
{225, 0,   0,   "长期受信报警"},
{226, 0,   0,   "通道断线报警"},
{227, 0,   0,   "长期差流报警"},
{228, 0,   0,   "跳灭磁开关出口异常"},
{229, 0,   0,   "停机出口异常"},
{230, 0,   0,   "线路过负荷"},
{231, 0,   0,   "Ⅰ段母线电压互感器开路"},
{232, 0,   0,   "Ⅱ段母线电压互感器开路"},
{233, 0,   0,   "过负荷信号"},
{234, 0,   0,   "开关量变位"},
{235, 0,   0,   "闭锁信号动作"},
{236, 0,   0,   "闭锁标识被清除"},
{237, 0,   0,   "跳闸压板投入"},
{238, 0,   0,   "合闸压板投入"},
{239, 0,   0,   "复合电压长期启动"},
{240, 0,   0,   "保护出口三极管击穿"},
{241, 0,   0,   "PT断线报警"},
{243, 0,   0,   "闭锁调压"},
{244, 0,   0,   "(并联启动时)其他侧复压长时间启动10秒报警"},
{245, 0,   0,   "零序过电压报警"},
{246, 0,   0,   "上电启动错误"},
{247, 0,   0,   "电源故障"},
{252, 0,   0,   "高频通道异常"},
{253, 0,   0,   "差动保护装置故障告警"},
{254, 0,   0,   "后备保护装置故障告警"},
{0,   0,   0,   "未定义信号"},
};

EVTALM  RCS_D2_Event[] ={
{1,   0,   0,   "保护板闭锁"},
{2,   0,   0,   "出口电源报警"},
{3,   0,   0,   "母差投入"},
{4,   0,   0,   "单母方式投入"},
{5,   0,   0,   "母联充电投入"},
{6,   0,   0,   "母联过流投入"},
{7,   0,   0,   "PT1投入"},
{8,   0,   0,   "PT2投入"},
{9,   0,   0,   "母联跳闸位置"},
{10,  0,   0,   "母联死区"},
{11,  0,   0,   "母差跳母联"},
{12,  0,   0,   "失灵跳母联"},
{13,  0,   0,   "跳母联2"},
{14,  0,   0,   "母差后备动作"},
{15,  0,   0,   "母联代路投入"},
{16,  0,   0,   "线路跟跳"},
{17,  0,   0,   "跟跳线路1"},
{18,  0,   0,   "跟跳线路2"},
{19,  0,   0,   "跟跳线路3"},
{20,  0,   0,   "监视方向闭锁"},
{21,  0,   0,   "跟跳线路4"},
{22,  0,   0,   "跟跳线路5"},
{23,  0,   0,   "跟跳线路6"},
{24,  0,   0,   "跟跳线路7"},
{25,  0,   0,   "跟跳线路8"},
{26,  0,   0,   "跟跳线路9"},
{27,  0,   0,   "跟跳线路10"},
{28,  0,   0,   "跟跳线路11"},
{29,  0,   0,   "跟跳线路12"},
{30,  0,   0,   "跟跳线路13"},
{31,  0,   0,   "跟跳线路14"},
{32,  0,   0,   "跟跳线路15"},
{33,  0,   0,   "跟跳线路16"},
{34,  0,   0,   "跟跳线路17"},
{35,  0,   0,   "跟跳线路18"},
{36,  0,   0,   "跟跳线路19"},
{37,  0,   0,   "跟跳线路20"},
{38,  0,   0,   "线路01刀闸位置报警"},
{39,  0,   0,   "线路02刀闸位置报警"},
{40,  0,   0,   "线路03刀闸位置报警"},
{41,  0,   0,   "线路04刀闸位置报警"},
{42,  0,   0,   "线路05刀闸位置报警"},
{43,  0,   0,   "线路06刀闸位置报警"},
{44,  0,   0,   "线路07刀闸位置报警"},
{45,  0,   0,   "线路08刀闸位置报警"},
{46,  0,   0,   "线路09刀闸位置报警"},
{47,  0,   0,   "线路10刀闸位置报警"},
{48,  0,   0,   "线路11刀闸位置报警"},
{49,  0,   0,   "线路12刀闸位置报警"},
{50,  0,   0,   "线路13刀闸位置报警"},
{51,  0,   0,   "线路14刀闸位置报警"},
{52,  0,   0,   "线路15刀闸位置报警"},
{53,  0,   0,   "线路16刀闸位置报警"},
{54,  0,   0,   "线路17刀闸位置报警"},
{55,  0,   0,   "线路18刀闸位置报警"},
{56,  0,   0,   "线路19刀闸位置报警"},
{57,  0,   0,   "线路20刀闸位置报警"},
{58,  0,   0,   "线路01TA断线"},
{59,  0,   0,   "线路02TA断线"},
{60,  0,   0,   "线路03TA断线"},
{61,  0,   0,   "线路04TA断线"},
{62,  0,   0,   "线路05TA断线"},
{63,  0,   0,   "线路06TA断线"},
{64,  0,   0,   "线路07TA断线"},
{65,  0,   0,   "线路08TA断线"},
{66,  0,   0,   "线路09TA断线"},
{67,  0,   0,   "线路10TA断线"},
{68,  0,   0,   "线路11TA断线"},
{69,  0,   0,   "A相跳闸"},
{70,  0,   0,   "B相跳闸"},
{71,  0,   0,   "C相跳闸"},
{72,  0,   0,   "线路12TA断线"},
{73,  0,   0,   "线路13TA断线"},
{74,  0,   0,   "线路14TA断线"},
{75,  0,   0,   "线路15TA断线"},
{76,  0,   0,   "线路16TA断线"},
{77,  0,   0,   "线路17TA断线"},
{78,  0,   0,   "线路18TA断线"},
{79,  0,   0,   "线路19TA断线"},
{80,  0,   0,   "线路20TA断线"},
{81,  0,   0,   "修改定值"},
{82,  0,   0,   "DSP报警"},
{83,  0,   0,   "线路1-I母刀闸位置"},
{84,  0,   0,   "线路2-I母刀闸位置"},
{85,  0,   0,   "线路3-I母刀闸位置"},
{86,  0,   0,   "线路4-I母刀闸位置"},
{87,  0,   0,   "线路5-I母刀闸位置"},
{88,  0,   0,   "线路6-I母刀闸位置"},
{89,  0,   0,   "线路7-I母刀闸位置"},
{90,  0,   0,   "线路8-I母刀闸位置"},
{91,  0,   0,   "线路9-I母刀闸位置"},
{92,  0,   0,   "线路10-I母刀闸位置"},
{93,  0,   0,   "线路11-I母刀闸位置"},
{94,  0,   0,   "线路12-I母刀闸位置"},
{95,  0,   0,   "线路13-I母刀闸位置"},
{96,  0,   0,   "线路14-I母刀闸位置"},
{97,  0,   0,   "线路15-I母刀闸位置"},
{98,  0,   0,   "线路16-I母刀闸位置"},
{99,  0,   0,   "线路17-I母刀闸位置"},
{100, 0,   0,   "线路18-I母刀闸位置"},
{101, 0,   0,   "线路19-I母刀闸位置"},
{102, 0,   0,   "线路20-I母刀闸位置"},
{103, 0,   0,   "母联TA断线"},
{104, 0,   0,   "该区定值无效"},
{105, 0,   0,   "线路1-II母刀闸位置"},
{106, 0,   0,   "线路2-II母刀闸位置"},
{107, 0,   0,   "线路3-II母刀闸位置"},
{108, 0,   0,   "线路4-II母刀闸位置"},
{109, 0,   0,   "线路5-II母刀闸位置"},
{110, 0,   0,   "线路6-II母刀闸位置"},
{111, 0,   0,   "线路7-II母刀闸位置"},
{112, 0,   0,   "线路8-II母刀闸位置"},
{113, 0,   0,   "线路9-II母刀闸位置"},
{114, 0,   0,   "线路10-II母刀闸位置"},
{115, 0,   0,   "线路11-II母刀闸位置"},
{116, 0,   0,   "线路12-II母刀闸位置"},
{117, 0,   0,   "线路13-II母刀闸位置"},
{118, 0,   0,   "线路14-II母刀闸位置"},
{119, 0,   0,   "线路15-II母刀闸位置"},
{120, 0,   0,   "线路16-II母刀闸位置"},
{121, 0,   0,   "线路17-II母刀闸位置"},
{122, 0,   0,   "线路18-II母刀闸位置"},
{123, 0,   0,   "线路19-II母刀闸位置"},
{124, 0,   0,   "线路20-II母刀闸位置"},
{125, 0,   0,   "管理板起动"},
{126, 0,   0,   "失灵启动"},
{127, 0,   0,   "失灵保护出口"},
{128, 0,   0,   "失灵起动开入"},
{129, 0,   0,   "线路1三跳闸开入"},
{130, 0,   0,   "线路2A相跳闸开入"},
{131, 0,   0,   "线路2B相跳闸开入"},
{132, 0,   0,   "线路2C相跳闸开入"},
{133, 0,   0,   "线路3A相跳闸开入"},
{134, 0,   0,   "线路3B相跳闸开入"},
{135, 0,   0,   "线路3C相跳闸开入"},
{136, 0,   0,   "线路4A相跳闸开入"},
{137, 0,   0,   "线路4B相跳闸开入"},
{138, 0,   0,   "线路4C相跳闸开入"},
{139, 0,   0,   "线路5A相跳闸开入"},
{140, 0,   0,   "线路5B相跳闸开入"},
{141, 0,   0,   "线路5C相跳闸开入"},
{142, 0,   0,   "线路6三跳闸开入"},
{143, 0,   0,   "线路7A相跳闸开入"},
{144, 0,   0,   "线路7B相跳闸开入"},
{145, 0,   0,   "线路7C相跳闸开入"},
{146, 0,   0,   "线路8A相跳闸开入"},
{147, 0,   0,   "线路8B相跳闸开入"},
{148, 0,   0,   "线路8C相跳闸开入"},
{149, 0,   0,   "跳母联"},
{150, 0,   0,   "1母联失灵保护动作"},
{151, 0,   0,   "跳Ⅰ母"},
{152, 0,   0,   "跳Ⅱ母"},
{153, 0,   0,   "1母线差动保护出口"},
{154, 0,   0,   "2母线差动保护出口"},
{155, 0,   0,   "3母线差动保护出口"},
{156, 0,   0,   "4母线差动保护出口"},
{157, 0,   0,   "母联过流保护出口"},
{158, 0,   0,   "充电保护出口"},
{159, 0,   0,   "线路10A相跳开入"},
{160, 0,   0,   "2母联失灵保护动作"},
{161, 0,   0,   "3母联失灵保护动作"},
{162, 0,   0,   "4母联失灵保护动作"},
{163, 0,   0,   "母联失灵保护出口"},
{164, 0,   0,   "电压突变保护出口"},
{165, 0,   0,   "负序电压保护出口"},
{166, 0,   0,   "线路10B相跳闸开入"},
{167, 0,   0,   "线路10C相跳闸开入"},
{168, 0,   0,   "线路11三跳闸开入"},
{169, 0,   0,   "线路12A相跳闸开入"},
{170, 0,   0,   "线路12B相跳闸开入"},
{171, 0,   0,   "线路12C相跳闸开入"},
{172, 0,   0,   "线路13A相跳闸开入"},
{173, 0,   0,   "线路13B相跳闸开入"},
{174, 0,   0,   "线路13C相跳闸开入"},
{175, 0,   0,   "线路14A相跳闸开入"},
{176, 0,   0,   "线路14B相跳闸开入"},
{177, 0,   0,   "线路14C相跳闸开入"},
{178, 0,   0,   "线路15A相跳闸开入"},
{179, 0,   0,   "线路15B相跳闸开入"},
{180, 0,   0,   "线路15C相跳闸开入"},
{181, 0,   0,   "线路16三跳闸开入"},
{182, 0,   0,   "线路17A相跳闸开入"},
{183, 0,   0,   "线路17B相跳闸开入"},
{184, 0,   0,   "线路17C相跳闸开入"},
{185, 0,   0,   "线路18A相跳闸开入"},
{186, 0,   0,   "线路18B相跳闸开入"},
{187, 0,   0,   "线路18C相跳闸开入"},
{188, 0,   0,   "线路19A相跳闸开入"},
{189, 0,   0,   "线路19B相跳闸开入"},
{190, 0,   0,   "线路19C相跳闸开入"},
{191, 0,   0,   "装置本机故障"},
{192, 0,   0,   "通信通道异常"},
{193, 0,   0,   "内部随机存储器异常"},
{194, 0,   0,   "数据(外部)随机存储器异常"},
{195, 0,   0,   "程序(只读)存储器出错"},
{196, 0,   0,   "EEPROM出错"},
{197, 0,   0,   "采样数据异常报警"},
{198, 0,   0,   "开关拒动"},
{199, 0,   0,   "液晶显示故障报警"},
{200, 0,   0,   "输出光电隔离击穿"},
{201, 0,   0,   "输出光电隔离无效"},
{202, 0,   0,   "光电隔离失电报警"},
{203, 0,   0,   "控制回路断线"},
{204, 0,   0,   "跳闸压力异常"},
{205, 0,   0,   "合