{161, 0, 0, "过负荷I侧A相"},
{162, 0, 0, "过负荷I侧B相"},
{163, 0, 0, "过负荷I侧C相"},
{164, 0, 0, "过负荷II侧A相"},
{165, 0, 0, "过负荷II侧B相"},
{166, 0, 0, "过负荷II侧C相"},
{167, 0, 0, "过负荷III侧A相"},
{168, 0, 0, "过负荷III侧B相"},
{169, 0, 0, "过负荷III侧C相"},
{170, 0, 0, "过负荷IV侧A相"},
{171, 0, 0, "过负荷IV侧B相"},
{172, 0, 0, "过负荷IV侧C相"},
{173, 0, 0, "过负荷低压绕组A相"},
{174, 0, 0, "过负荷低压绕组B相"},
{175, 0, 0, "过负荷低压绕组C相"},
{176, 0, 0, "过负荷公共绕组A相"},
{177, 0, 0, "过负荷公共绕组B相"},
{178, 0, 0, "过负荷公共绕组C相"},
{179, 0, 0, "I侧旁路代路投入"},
{180, 0, 0, "II侧旁路代路投入"},
{181, 0, 0, "管理板低压绕组后备保护起动"},
{182, 0, 0, "管理板定时限过激起动"},
{183, 0, 0, "管理板反时限过激起动"},
{184, 0, 0, "低压绕组过流I段第一时限"},
{185, 0, 0, "低压绕组过流I段第二时限"},
{186, 0, 0, "III侧零序过压"},
{187, 0, 0, "IV侧零序过压"},
{188, 0, 0, "III侧过流I段第一时限"},
{189, 0, 0, "III侧过流I段第二时限"},
{190, 0, 0, "III侧过流II段第一时限"},
{191, 0, 0, "III侧过流II段第二时限"},
{192, 0, 0, "IV侧过流I段第一时限"},
{193, 0, 0, "IV侧过流I段第二时限"},
{194, 0, 0, "数据(外部)随机存储器异常"},
{195, 0, 0, "程序(只读)存储器出错"},
{196, 0, 0, "EEPROM出错"},
{197, 0, 0, "I侧阻抗退出过流"},
{198, 0, 0, "II侧阻抗退出过流"},
{199, 0, 0, "I侧阻抗I段第一时限"},
{200, 0, 0, "输出光电隔离击穿"},
{201, 0, 0, "I侧阻抗I段第二时限"},
{202, 0, 0, "光电隔离失电报警"},
{203, 0, 0, "I侧阻抗II段第一时限"},
{204, 0, 0, "I侧阻抗II段第二时限"},
{205, 0, 0, "II侧阻抗I段第一时限"},
{206, 0, 0, "II侧阻抗I段第二时限"},
{207, 0, 0, "II侧阻抗II段第一时限"},
{208, 0, 0, "II侧阻抗II段第二时限"},
{209, 0, 0, "定时限过激磁"},
{210, 0, 0, "反时限过激磁"},
{211, 0, 0, "装置内部通信故障"},
{212, 0, 0, "联跳低抗开关"},
{213, 0, 0, "管理板低压侧和电流保护起动"},
{214, 0, 0, "长期启动报警"},
{215, 0, 0, "不对应启动报警"},
{216, 0, 0, "投过激磁保护"},
{217, 0, 0, "II侧1支路TA异常"},
{218, 0, 0, "II侧2支路TA异常"},
{219, 0, 0, "低压绕组TA异常"},
{220, 0, 0, "I侧间隙零序过流第一时限"},
{221, 0, 0, "I侧间隙零序过流第二时限"},
{222, 0, 0, "定值校验出错"},
{223, 0, 0, "该区定值无效"},
{224, 0, 0, "I侧零序过压第一时限"},
{225, 0, 0, "I侧零序过压第二时限"},
{226, 0, 0, "II侧间隙零序过流第一时限"},
{227, 0, 0, "II侧间隙零序过流第二时限"},
{228, 0, 0, "II侧零序过压第一时限"},
{229, 0, 0, "II侧零序过压第二时限"},
{230, 0, 0, "I侧零序过流II段第三时限"},
{231, 0, 0, "II侧零序过流II段第三时限"},
{232, 0, 0, "I侧零序过流I段第三时限"},
{233, 0, 0, "II侧零序过流I段第三时限"},
{234, 0, 0, "III与IV侧过流第一时限"},
{235, 0, 0, "III与IV侧过流第二时限"},
{236, 0, 0, "投分侧差动保护"},
{237, 0, 0, "管理板分侧差动启动"},
{238, 0, 0, "分侧比率差动"},
{239, 0, 0, "分侧差动速断"},
{240, 0, 0, "变压器开关失灵"},
{241, 0, 0, "II侧1支路零序过流I段第一时限"},
{242, 0, 0, "II侧1支路零序过流I段第二时限"},
{243, 0, 0, "II侧1支路零序过流II段第一时限"},
{244, 0, 0, "II侧2支路零序过流I段第一时限"},
{245, 0, 0, "II侧2支路零序过流I段第二时限"},
{246, 0, 0, "II侧2支路零序过流II段第一时限"},
{247, 0, 0, "I侧过流I段第三时限"},
{248, 0, 0, "II侧过流I段第三时限"},
{249, 0, 0, "II侧1支路过流I段"},
{250, 0, 0, "II侧1支路过流II段"},
{251, 0, 0, "II侧1支路过流III段"},
{252, 0, 0, "II侧1支路过流IV段"},
{253, 0, 0, "II侧1支路A相跳闸"},
{254, 0, 0, "II侧1支路B相跳闸"},
{0, 0, 0, "未定义信号"},
};
EVTALM RCS_C4_Event[] ={
{1, 0, 0, "高压侧复合电压闭锁方向过流t1"},
{2, 0, 0, "高压侧复合电压闭锁方向过流t2"},
{3, 0, 0, "高压侧复合电压过流t1"},
{4, 0, 0, "高压侧复合电压过流t2"},
{5, 0, 0, "高压侧零序方向过流I段t1"},
{6, 0, 0, "高压侧零序方向过流I段t2"},
{7, 0, 0, "高压侧零序方向过流II段t1"},
{8, 0, 0, "高压侧零序方向过流II段t2"},
{9, 0, 0, "高压侧零序过流t1"},
{10, 0, 0, "高压侧零序过流t2"},
{11, 0, 0, "高压侧中性点零序过流t1"},
{12, 0, 0, "高压侧间隙过流t1"},
{13, 0, 0, "高压侧零序过压t1"},
{14, 0, 0, "高压侧非全相t1"},
{15, 0, 0, "高压侧零序中间t1"},
{16, 0, 0, "I侧变压器过负荷"},
{17, 0, 0, "高压侧过负荷闭锁调压"},
{18, 0, 0, "高压侧风扇启动"},
{19, 0, 0, "I侧PT断线"},
{20, 0, 0, "中压侧复合电压闭锁方向过流t1"},
{21, 0, 0, "中压侧复合电压闭锁方向过流t2"},
{22, 0, 0, "中压侧复合电压过流t1"},
{23, 0, 0, "中压侧复合电压过流t2"},
{24, 0, 0, "中压侧复合电压闭锁方向限时速断t1"},
{25, 0, 0, "中压侧复合电压闭锁方向限时速断t2"},
{26, 0, 0, "中压侧零序过流t1"},
{27, 0, 0, "中压侧零序过流t2"},
{28, 0, 0, "中压侧中性点零序过流t1"},
{29, 0, 0, "中压侧间隙过流t1"},
{30, 0, 0, "中压侧零序过压t1"},
{31, 0, 0, "中压侧零序中间t1"},
{32, 0, 0, "II侧变压器过负荷"},
{33, 0, 0, "II侧PT断线"},
{34, 0, 0, "低压侧复合电压闭锁方向过流t1"},
{35, 0, 0, "低压侧复合电压闭锁方向过流t2"},
{36, 0, 0, "低压侧复合电压闭锁方向过流t3"},
{37, 0, 0, "低压侧复合电压过流t1"},
{38, 0, 0, "低压侧复合电压过流t2"},
{39, 0, 0, "低压侧复合电压过流t3"},
{40, 0, 0, "低压侧低压闭锁限时速断t1"},
{41, 0, 0, "低压侧低压闭锁限时速断t2"},
{42, 0, 0, "低压侧低压闭锁限时速断t3"},
{43, 0, 0, "低压侧零序电压告警"},
{44, 0, 0, "III侧变压器过负荷"},
{45, 0, 0, "III侧PT断线"},
{46, 0, 0, "低压侧母线过流t1"},
{47, 0, 0, "低压侧母线过流t2"},
{48, 0, 0, "低压侧母线过流t3"},
{49, 0, 0, "低压侧A分支复合电压闭锁过流t1"},
{50, 0, 0, "低压侧A分支复合电压闭锁过流t2"},
{51, 0, 0, "低压侧A分支复合电压闭锁过流t3"},
{52, 0, 0, "低压侧A分支复合电压闭锁限时速断t1"},
{53, 0, 0, "低压侧A分支复合电压闭锁限时速断t2"},
{54, 0, 0, "低压侧A分支复合电压闭锁限时速断t3"},
{55, 0, 0, "低压侧A分支过负荷"},
{56, 0, 0, "低压侧A分支PT断线"},
{57, 0, 0, "低压侧B分支复合电压闭锁过流t1"},
{58, 0, 0, "低压侧B分支复合电压闭锁过流t2"},
{59, 0, 0, "低压侧B分支复合电压闭锁过流t3"},
{60, 0, 0, "低压侧B分支复合电压闭锁限时速断t1"},
{61, 0, 0, "低压侧B分支复合电压闭锁限时速断t2"},
{62, 0, 0, "低压侧B分支复合电压闭锁限时速断t3"},
{64, 0, 0, "低压侧B分支PT断线"},
{65, 0, 0, "公共绕组过流t1"},
{66, 0, 0, "中性点零序过流t1"},
{67, 0, 0, "公共绕组过负荷"},
{68, 0, 0, "中性点零序过流告警"},
{163, 0, 0, "低压侧B分支过负荷"},
{0, 0, 0, "未定义信号"},
};
EVTALM RCS_C5_Event[] ={
{17, 0, 0, "III侧1支路TA异常"},
{18, 0, 0, "III侧2支路TA异常"},
{19, 0, 0, "III侧1支路TV异常"},
{20, 0, 0, "III侧2支路TV异常"},
{21, 0, 0, "II侧1支路TV异常"},
{22, 0, 0, "II侧2支路TV异常"},
{23, 0, 0, "III侧1支路过负荷"},
{24, 0, 0, "III侧2支路过负荷"},
{25, 0, 0, "II侧1支路过负荷"},
{26, 0, 0, "II侧2支路过负荷"},
{27, 0, 0, "III侧1支路零序电压告警"},
{28, 0, 0, "III侧2支路零序电压告警"},
{29, 0, 0, "II侧1支路零序电压告警"},
{30, 0, 0, "II侧2支路零序电压告警"},
{31, 0, 0, "III侧1支路TA断线"},
{32, 0, 0, "III侧2支路TA断线"},
{33, 0, 0, "投III侧1支路后备保护"},
{34, 0, 0, "投III侧2支路后备保护"},
{35, 0, 0, "投II侧1支路后备保护"},
{36, 0, 0, "投II侧2支路后备保护"},
{37, 0, 0, "III侧1支路电压退出"},
{38, 0, 0, "III侧2支路电压退出"},
{39, 0, 0, "II侧1支路电压退出"},
{40, 0, 0, "II侧2支路电压退出"},
{41, 0, 0, "II侧1支路开关跳闸"},
{42, 0, 0, "II侧2支路开关跳闸"},
{43, 0, 0, "III侧1支路开关跳闸"},
{44, 0, 0, "III侧2支路开关跳闸"},
{45, 0, 0, "V侧过流I段"},
{46, 0, 0, "定时限过激磁I段"},
{47, 0, 0, "定时限过激磁II段"},
{48, 0, 0, "V侧TA异常"},
{49, 0, 0, "V侧过负荷"},
{50, 0, 0, "投V侧过流保护"},
{51, 0, 0, "管理板定时限过激磁I段起动"},
{52, 0, 0, "管理板定时限过激磁II段起动"},
{53, 0, 0, "管理板V侧后备保护起动"},
{54, 0, 0, "V侧TA断线"},
{55, 0, 0, "I、II侧和电流I段"},
{56, 0, 0, "I、II侧和电流II段"},
{57, 0, 0, "管理板I、II侧和电流起动"},
{58, 0, 0, "I侧阻抗I段第三时限"},
{59, 0, 0, "II侧阻抗I段第三时限"},
{60, 0, 0, "I侧接地阻抗II段第二时限"},
{61, 0, 0, "I侧接地阻抗II段第一时限"},
{62, 0, 0, "I侧接地阻抗I段第二时限"},
{63, 0, 0, "I侧接地阻抗I段第一时限"},
{64, 0, 0, "II侧接地阻抗II段第二时限"},
{65, 0, 0, "II侧接地阻抗II段第一时限"},
{66, 0, 0, "II侧接地阻抗I段第二时限"},
{67, 0, 0, "II侧接地阻抗I段第一时限"},
{68, 0, 0, "投检修态"},
{69, 0, 0, "I侧复压启动"},
{70, 0, 0, "II侧复压启动"},
{71, 0, 0, "III侧复压启动"},
{72, 0, 0, "IV侧复压启动"},
{0, 0, 0, "未定义信号"},
};
EVTALM RCS_C6_Event[] ={
{3, 0, 0, "CT报警"},
{4, 0, 0, "出口三极管电位"},
{5, 0, 0, "差动保护投入"},
{6, 0, 0, "过流保护投入"},
{7, 0, 0, "复压过流保护投入"},
{8, 0, 0, "零序过流保护投入"},
{9, 0, 0, "间隙零序保护投入"},
{10, 0, 0, "备用压板投入"},
{11, 0, 0, "并联启动投110kv侧复压启动"},
{12, 0, 0, "中压或低压侧复压启动节点输入"},
{13, 0, 0, "接地零序保护投入"},
{14, 0, 0, "不接地零序保护投入"},
{15, 0, 0, "其它侧复压动作"},
{16, 0, 0, "本侧PT退出"},
{17, 0, 0, "本侧复合电压元件动作"},
{18, 0, 0, "跳母联"},
{19, 0, 0, "跳出口"},
{20, 0, 0, "全跳"},
{21, 0, 0, "装置检修"},
{22, 0, 0, "信号复归"},
{34, 0, 0, "装置报警"},
{35, 0, 0, "装置闭锁"},
{52, 0, 0, "接地报警"},
{53, 0, 0, "正序反时限动作"},
{54, 0, 0, "负序过流Ⅰ段动作"},
{55, 0, 0, "负序过流Ⅱ段动作"},
{56, 0, 0, "零序过压动作"},
{57, 0, 0, "低压侧零序过流Ⅰ段动作"},
{58, 0, 0, "低压侧零序过流Ⅱ段动作"},
{59, 0, 0, "低压侧零序过流Ⅲ段动作"},
{60, 0, 0, "低压侧零序反时限动作"},
{61, 0, 0, "低电压保护动作"},
{62, 0, 0, "零序过流Ⅲ段动作"},
{63, 0, 0, "复压过流Ⅰ段动作"},
{64, 0, 0, "复压过流Ⅱ段动作"},
{65, 0, 0, "复压过流Ⅲ段动作"},
{66, 0, 0, "复压过流Ⅰ段第一时限动作"},
{67, 0, 0, "复压过流Ⅰ段第二时限动作"},
{68, 0, 0, "复压过流Ⅱ段第一时限动作"},
{69, 0, 0, "复压过流Ⅱ段第二时限动作"},
{70, 0, 0, "零序过流Ⅰ段动作"},
{71, 0, 0, "零序过流Ⅱ段动作"},
{72, 0, 0, "零序过流Ⅰ段第一时限动作"},
{73, 0, 0, "零序过流Ⅰ段第二时限动作"},
{74, 0, 0, "零序过流Ⅱ段第一时限动作"},
{75, 0, 0, "零序过流Ⅱ段第二时限动作"},
{76, 0, 0, "零序过流Ⅲ段第一时限动作"},
{77, 0, 0, "零序过流Ⅲ段第二时限动作"},
{78, 0, 0, "零序过压Ⅰ时限动作"},
{79, 0, 0, "零序过压Ⅱ时限动作"},
{80, 0, 0, "间隙零序过压Ⅰ时限动作"},
{81, 0, 0, "间隙零序过压Ⅱ时限动作"},
{82, 0, 0, "间隙零序过流Ⅰ时限动作"},
{83, 0, 0, "间隙零序过流Ⅱ时限动作"},
{84, 0, 0, "复压过流Ⅳ段动作"},
{85, 0, 0, "限时电流速断第一时限动作"},
{86, 0, 0, "限时电流速断第二时限动作"},
{87, 0, 0, "零序过流Ⅰ段第三时限动作"},
{88, 0, 0, "零序过流Ⅱ段第三时限动作"},
{89, 0, 0, "间隙保护动作"},
{97, 0, 0, "非电量备用1跳闸动作"},
{98, 0, 0, "非电量备用2跳闸动作"},
{99, 0, 0, "冷控失电跳闸动作"},
{100, 0, 0, "重瓦斯动作"},
{101, 0, 0, "有载轻瓦斯动作"},
{102, 0, 0, "厂用变重瓦斯"},
{103, 0, 0, "非全相保护动作"},
{104, 0, 0, "失灵启动"},
{105, 0, 0, "起动"},
{106, 0, 0, "油温高跳闸"},
{107, 0, 0, "压力释放跳闸"},
{130, 0, 0, "备用非电量告警"},
{131, 0, 0, "本体有载轻瓦斯信号"},
{132, 0, 0, "本体有载重瓦斯信号"},
{133, 0, 0, "有载轻瓦斯信号"},