⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rcs900.h

📁 在Unix平台下完成的电力系统广发使用的IEC103规约的程序
💻 H
📖 第 1 页 / 共 5 页
字号:
{114, 0,   0,   "间隙"},
{115, 0,   0,   "非全相保护出口"},
{116, 0,   0,   "非全相Ⅰ段"},
{117, 0,   0,   "非全相Ⅱ段"},
{118, 0,   0,   "过励磁出口"},
{119, 0,   0,   "失灵电流起动"},
{120, 0,   0,   "三跳失败"},
{121, 0,   0,   "相电流突变元件启动"},
{122, 0,   0,   "差动电流突变元件启动"},
{123, 0,   0,   "复合电压闭锁元件启动保护出口"},
{124, 0,   0,   "变压器本体动作出口"},
{125, 0,   0,   "另一台主变零序过流"},
{126, 0,   0,   "零序跳不接地变"},
{127, 0,   0,   "非电量16信号A相"},
{128, 0,   0,   "重合闸出口"},
{129, 0,   0,   "非电量16信号B相"},
{130, 0,   0,   "非电量16信号C相"},
{131, 0,   0,   "有载重瓦斯信号"},
{132, 0,   0,   "有载轻瓦斯信号"},
{133, 0,   0,   "本体重瓦斯信号"},
{134, 0,   0,   "本体轻瓦斯信号"},
{135, 0,   0,   "压力释放动作信号"},
{136, 0,   0,   "油温高信号"},
{137, 0,   0,   "冷却器电源消失信号"},
{138, 0,   0,   "非电量备用跳闸开入信号"},
{139, 0,   0,   "备用1"},
{140, 0,   0,   "备用2"},
{141, 0,   0,   "备用3"},
{142, 0,   0,   "高压侧TWJ"},
{143, 0,   0,   "中压侧TWJ"},
{144, 0,   0,   "低压侧TWJ"},
{145, 0,   0,   "绕组温高信号"},
{146, 0,   0,   "本体油位高信号"},
{147, 0,   0,   "冷却器全停"},
{148, 0,   0,   "有载油位低"},
{149, 0,   0,   "断路器位置1"},
{150, 0,   0,   "断路器位置2"},
{151, 0,   0,   "断路器位置3"},
{152, 0,   0,   "油温高信号A相"},
{153, 0,   0,   "油温高信号B相"},
{154, 0,   0,   "油温高信号C相"},
{155, 0,   0,   "非电量4"},
{156, 0,   0,   "非电量4"},
{157, 0,   0,   "非电量4"},
{158, 0,   0,   "非电量2"},
{159, 0,   0,   "零序Ⅱ段一时限出口"},
{160, 0,   0,   "非电量2"},
{161, 0,   0,   "阻抗Ⅰ段出口"},
{162, 0,   0,   "阻抗Ⅱ段一时限出口"},
{163, 0,   0,   "阻抗Ⅱ段二时限出口"},
{164, 0,   0,   "阻抗Ⅲ段一时限出口"},
{165, 0,   0,   "阻抗Ⅲ段二时限出口"},
{166, 0,   0,   "非电量2"},
{167, 0,   0,   "非电量3"},
{168, 0,   0,   "非电量3"},
{169, 0,   0,   "非电量3"},
{170, 0,   0,   "冷控失电A相开入"},
{171, 0,   0,   "冷控失电B相开入"},
{172, 0,   0,   "冷控失电C相开入"},
{173, 0,   0,   "非电量9信号"},
{174, 0,   0,   "非电量2信号"},
{175, 0,   0,   "非电量3信号"},
{176, 0,   0,   "冷控失电开入"},
{177, 0,   0,   "非电量2"},
{178, 0,   0,   "非电量3"},
{179, 0,   0,   "非电量16信号"},
{180, 0,   0,   "三相不一致接点异常"},
{181, 0,   0,   "非电量2跳闸"},
{182, 0,   0,   "非电量3跳闸"},
{183, 0,   0,   "零序Ⅱ段二时限出口"},
{184, 0,   0,   "零序Ⅲ段一时限出口"},
{185, 0,   0,   "零序Ⅲ段二时限出口"},
{186, 0,   0,   "零序电压Ⅰ段保护出口"},
{187, 0,   0,   "零序电压Ⅱ段保护出口"},
{188, 0,   0,   "零序电压Ⅲ段"},
{189, 0,   0,   "光耦24V电源正常"},
{190, 0,   0,   "开关压力高"},
{191, 0,   0,   "装置本机故障"},
{192, 0,   0,   "通信通道异常"},
{193, 0,   0,   "内部随机存储器异常"},
{194, 0,   0,   "数据(外部)随机存储器异常"},
{195, 0,   0,   "程序(只读)存储器出错"},
{196, 0,   0,   "EEPROM出错"},
{197, 0,   0,   "采样数据异常报警"},
{198, 0,   0,   "开关拒动"},
{199, 0,   0,   "液晶显示故障报警"},
{200, 0,   0,   "输出光电隔离击穿"},
{201, 0,   0,   "输出光电隔离无效"},
{202, 0,   0,   "光电隔离失电报警"},
{203, 0,   0,   "控制回路断线"},
{204, 0,   0,   "跳闸压力异常"},
{205, 0,   0,   "合闸压力异常"},
{206, 0,   0,   "电流互感器开路(CT断线)"},
{207, 0,   0,   "压力降低断路器禁止操作"},
{208, 0,   0,   "电流变化量长期启动报警"},
{209, 0,   0,   "运行方式位置异常报警"},
{210, 0,   0,   "TWJ报警"},
{211, 0,   0,   "装置内部通信故障"},
{212, 0,   0,   "跳闸报警"},
{213, 0,   0,   "重合闸报警"},
{214, 0,   0,   "长期启动报警"},
{215, 0,   0,   "低电压报警"},
{216, 0,   0,   "过电压报警"},
{217, 0,   0,   "零序过电压"},
{218, 0,   0,   "零序过电流"},
{219, 0,   0,   "#1母线接地"},
{220, 0,   0,   "#2母线接地"},
{221, 0,   0,   "系统频率异常"},
{222, 0,   0,   "定值校验出错"},
{223, 0,   0,   "修改定值位置告警"},
{224, 0,   0,   "定值变化(换区)"},
{225, 0,   0,   "长期受信报警"},
{226, 0,   0,   "通道断线报警"},
{227, 0,   0,   "长期差流报警"},
{228, 0,   0,   "跳灭磁开关出口异常"},
{229, 0,   0,   "停机出口异常"},
{230, 0,   0,   "线路过负荷"},
{231, 0,   0,   "Ⅰ段母线电压互感器开路"},
{232, 0,   0,   "Ⅱ段母线电压互感器开路"},
{233, 0,   0,   "过负荷信号"},
{234, 0,   0,   "开关量变位"},
{235, 0,   0,   "闭锁信号动作"},
{236, 0,   0,   "闭锁标识被清除"},
{237, 0,   0,   "跳闸压板投入"},
{238, 0,   0,   "合闸压板投入"},
{239, 0,   0,   "复合电压长期启动"},
{240, 0,   0,   "上电启动错误"},
{241, 0,   0,   "电源故障"},
{242, 0,   0,   "起动CPU长期起动"},
{243, 0,   0,   "起动CPU通讯错"},
{244, 0,   0,   "起动CPU_ROM错"},
{245, 0,   0,   "起动CPU_定值错"},
{246, 0,   0,   "跳闸出口正常"},
{247, 0,   0,   "跳闸出口异常"},
{248, 0,   0,   "压力突变"},
{249, 0,   0,   "本体油位低"},
{250, 0,   0,   "变压器接线方式错误"},
{251, 0,   0,   "变压器平衡系数错误"},
{252, 0,   0,   "高频通道异常"},
{253, 0,   0,   "差动保护装置故障告警"},
{254, 0,   0,   "后备保护装置故障告警"},
{0,   0,   0,   "未定义信号"},
};

EVTALM  RCS_C3_Event[] ={
{1,   0,   0,   "II侧1支路C相跳闸"},
{2,   0,   0,   "II侧2支路A相跳闸"},
{3,   0,   0,   "II侧2支路B相跳闸"},
{4,   0,   0,   "II侧2支路C相跳闸"},
{5,   0,   0,   "III侧1支路过流I段"},
{6,   0,   0,   "III侧1支路过流II段"},
{7,   0,   0,   "III侧1支路过流III段"},
{8,   0,   0,   "III侧1支路过流IV段"},
{9,   0,   0,   "III侧2支路过流I段"},
{10,  0,   0,   "III侧2支路过流II段"},
{11,  0,   0,   "III侧2支路过流III段"},
{12,  0,   0,   "III侧2支路过流IV段"},
{13,  0,   0,   "II侧2支路过流I段"},
{14,  0,   0,   "II侧2支路过流II段"},
{15,  0,   0,   "II侧2支路过流III段"},
{16,  0,   0,   "II侧2支路过流IV段"},
{17,  0,   0,   "公共绕组TA异常"},
{18,  0,   0,   "IV侧TA异常"},
{19,  0,   0,   "III侧TA异常"},
{20,  0,   0,   "监视方向闭锁"},
{21,  0,   0,   "II侧TA异常"},
{22,  0,   0,   "I侧TA异常"},
{23,  0,   0,   "差动保护差流异常"},
{24,  0,   0,   "零序差动保护差流异常"},
{25,  0,   0,   "I侧阻抗I段第三时限"},
{26,  0,   0,   "II侧阻抗I段第三时限"},
{27,  0,   0,   "I侧TV异常"},
{28,  0,   0,   "II侧TV异常"},
{29,  0,   0,   "III侧TV异常"},
{30,  0,   0,   "IV侧TV异常"},
{31,  0,   0,   "公共绕组TA断线"},
{32,  0,   0,   "IV侧TA断线"},
{33,  0,   0,   "III侧TA断线"},
{34,  0,   0,   "II侧TA断线"},
{35,  0,   0,   "I侧TA断线"},
{36,  0,   0,   "I侧过负荷I段"},
{37,  0,   0,   "I侧过负荷II段"},
{38,  0,   0,   "I侧起动风冷I段"},
{39,  0,   0,   "I侧起动风冷II段"},
{40,  0,   0,   "I侧过载闭锁调压"},
{41,  0,   0,   "TA断线"},
{42,  0,   0,   "II侧过负荷I段"},
{43,  0,   0,   "II侧过负荷II段"},
{44,  0,   0,   "II侧起动风冷I段"},
{45,  0,   0,   "II侧起动风冷II段"},
{46,  0,   0,   "II侧过载闭锁调压"},
{47,  0,   0,   "II侧过流IV段第二时限"},
{48,  0,   0,   "III侧过负荷"},
{49,  0,   0,   "II侧过流IV段第一时限"},
{50,  0,   0,   "III侧零序电压告警"},
{51,  0,   0,   "IV侧过负荷"},
{52,  0,   0,   "分侧差动保护差流异常"},
{53,  0,   0,   "IV侧零序电压告警"},
{54,  0,   0,   "公共绕组起动风冷"},
{55,  0,   0,   "公共绕组零序电流报警"},
{56,  0,   0,   "公共绕组过负荷"},
{57,  0,   0,   "投差动保护"},
{58,  0,   0,   "投零序差动保护"},
{59,  0,   0,   "投I侧相间后备保护"},
{60,  0,   0,   "投I侧接地零序保护"},
{61,  0,   0,   "差动速断"},
{62,  0,   0,   "比率差动"},
{63,  0,   0,   "投I侧不接地零序保护"},
{64,  0,   0,   "投II侧相间后备保护"},
{65,  0,   0,   "投II侧接地零序保护"},
{66,  0,   0,   "投II侧不接地零序保护"},
{67,  0,   0,   "投III侧过流保护"},
{68,  0,   0,   "投IV侧过流保护"},
{69,  0,   0,   "I侧A相跳闸"},
{70,  0,   0,   "I侧B相跳闸"},
{71,  0,   0,   "I侧C相跳闸"},
{72,  0,   0,   "投公共绕组后备保护"},
{73,  0,   0,   "IV侧电压退出"},
{74,  0,   0,   "III侧电压退出"},
{75,  0,   0,   "II侧电压退出"},
{76,  0,   0,   "I侧电压退出"},
{77,  0,   0,   "管理板差动起动"},
{78,  0,   0,   "管理板工频变化量差动起动"},
{79,  0,   0,   "管理板零序差动起动"},
{80,  0,   0,   "管理板I侧后备保护起动"},
{81,  0,   0,   "修改定值"},
{82,  0,   0,   "DSP出错"},
{83,  0,   0,   "管理板II侧后备保护起动"},
{84,  0,   0,   "管理板III侧后备保护起动"},
{85,  0,   0,   "管理板IV侧后备保护起动"},
{86,  0,   0,   "管理板公共绕组后备保护起动"},
{87,  0,   0,   "零序差动速断"},
{88,  0,   0,   "I侧过流I段第一时限"},
{89,  0,   0,   "I侧过流I段第二时限"},
{90,  0,   0,   "I侧过流II段第一时限"},
{91,  0,   0,   "I侧过流II段第二时限"},
{92,  0,   0,   "I侧过流III段第一时限"},
{93,  0,   0,   "I侧过流III段第二时限"},
{94,  0,   0,   "I侧零序过流I段第一时限"},
{95,  0,   0,   "I侧零序过流I段第二时限"},
{96,  0,   0,   "I侧零序过流II段第一时限"},
{97,  0,   0,   "I侧零序过流II段第二时限"},
{98,  0,   0,   "I侧零序过流III段第一时限"},
{99,  0,   0,   "I侧零序过流III段第二时限"},
{100, 0,   0,   "I侧间隙零序过流过压第一时限"},
{101, 0,   0,   "I侧间隙零序过流过压第二时限"},
{102, 0,   0,   "公共绕组零序过流"},
{103, 0,   0,   "公共绕组过流"},
{104, 0,   0,   "II侧过流I段第一时限"},
{105, 0,   0,   "II侧过流I段第二时限"},
{106, 0,   0,   "零序比率差动"},
{107, 0,   0,   "工频变化量差动"},
{108, 0,   0,   "II侧过流II段第一时限"},
{109, 0,   0,   "II侧过流II段第二时限"},
{110, 0,   0,   "II侧过流III段第一时限"},
{111, 0,   0,   "II侧过流III段第二时限"},
{112, 0,   0,   "II侧零序过流I段第一时限"},
{113, 0,   0,   "II侧零序过流I段第二时限"},
{114, 0,   0,   "II侧零序过流II段第一时限"},
{115, 0,   0,   "II侧零序过流II段第二时限"},
{116, 0,   0,   "II侧零序过流III段第一时限"},
{117, 0,   0,   "II侧零序过流III段第二时限"},
{118, 0,   0,   "II侧间隙零序过流过压第一时限"},
{119, 0,   0,   "II侧间隙零序过流过压第二时限"},
{120, 0,   0,   "III侧过流I段"},
{121, 0,   0,   "III侧过流II段"},
{122, 0,   0,   "III侧过流III段"},
{123, 0,   0,   "III侧过流IV段"},
{124, 0,   0,   "III侧过流V段"},
{125, 0,   0,   "IV侧过流I段"},
{126, 0,   0,   "IV侧过流II段"},
{127, 0,   0,   "IV侧过流III段"},
{128, 0,   0,   "IV侧过流IV段"},
{129, 0,   0,   "IV侧过流V段"},
{130, 0,   0,   "I侧开关跳闸"},
{131, 0,   0,   "II侧开关跳闸"},
{132, 0,   0,   "III侧开关跳闸"},
{133, 0,   0,   "IV侧开关跳闸"},
{134, 0,   0,   "I侧母联开关跳闸"},
{135, 0,   0,   "II侧母联开关跳闸"},
{136, 0,   0,   "III与IV侧分段开关跳闸"},
{137, 0,   0,   "II侧A相跳闸"},
{138, 0,   0,   "II侧B相跳闸"},
{139, 0,   0,   "II侧C相跳闸"},
{140, 0,   0,   "III侧A相跳闸"},
{141, 0,   0,   "III侧B相跳闸"},
{142, 0,   0,   "III侧C相跳闸"},
{143, 0,   0,   "IV侧A相跳闸"},
{144, 0,   0,   "IV侧B相跳闸"},
{145, 0,   0,   "IV侧C相跳闸"},
{146, 0,   0,   "差动A相跳闸"},
{147, 0,   0,   "差动B相跳闸"},
{148, 0,   0,   "差动C相跳闸"},
{149, 0,   0,   "低压绕组A相跳闸"},
{150, 0,   0,   "低压绕组B相跳闸"},
{151, 0,   0,   "低压绕组C相跳闸"},
{152, 0,   0,   "反时限过激磁告警"},
{153, 0,   0,   "定时限过激磁告警"},
{154, 0,   0,   "I侧1支路TA异常"},
{155, 0,   0,   "I侧2支路TA异常"},
{156, 0,   0,   "I侧1支路TA断线"},
{157, 0,   0,   "I侧2支路TA断线"},
{158, 0,   0,   "II侧1支路TA断线"},
{159, 0,   0,   "II侧2支路TA断线"},
{160, 0,   0,   "低压绕组过负荷"},

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =