📄 rcs900.h

📁 在Unix平台下完成的电力系统广发使用的IEC103规约的程序
💻 H
📖 第 1 页 / 共 5 页
字号:
{61,  0,   0,   "差动速断保护出口"},
{62,  0,   0,   "比率差动保护出口"},
{63,  0,   0,   "充电保护动作"},
{64,  0,   0,   "三相过电压发远跳命令"},
{65,  0,   0,   "失灵跳母联1"},
{66,  0,   0,   "失灵跳母联2"},
{67,  0,   0,   "失灵跳分段1"},
{68,  0,   0,   "失灵跳分段2"},
{69,  0,   0,   "失灵跳一母"},
{70,  0,   0,   "失灵跳二母"},
{71,  0,   0,   "失灵跳三母"},
{72,  0,   0,   "失灵投四母"},
{73,  0,   0,   "母联1失灵"},
{74,  0,   0,   "母联2失灵"},
{75,  0,   0,   "分段1失灵"},
{76,  0,   0,   "分段2失灵"},
{77,  0,   0,   "投失灵保护"},
{78,  0,   0,   "投母联1带路"},
{79,  0,   0,   "投母联2带路"},
{80,  0,   0,   "投一母运行"},
{81,  0,   0,   "投二母运行"},
{82,  0,   0,   "投三母运行"},
{83,  0,   0,   "投四母运行"},
{84,  0,   0,   "投互联1"},
{85,  0,   0,   "投互联2"},
{86,  0,   0,   "投互联3"},
{87,  0,   0,   "投互联4"},
{88,  0,   0,   "母联1代路1"},
{89,  0,   0,   "母联1代路2"},
{90,  0,   0,   "母联2代路1"},
{91,  0,   0,   "过流保护出口"},
{92,  0,   0,   "母联2代路2"},
{94,  0,   0,   "过流Ⅰ段"},
{95,  0,   0,   "过流Ⅱ段"},
{96,  0,   0,   "过流Ⅲ段"},
{97,  0,   0,   "过流Ⅳ段"},
{98,  0,   0,   "沟通三跳"},
{99,  0,   0,   "后合跳闸"},
{100, 0,   0,   "重瓦斯动作"},
{101, 0,   0,   "有载轻瓦斯动作"},
{102, 0,   0,   "母联1失灵开入异常"},
{103, 0,   0,   "母联2失灵开入异常"},
{104, 0,   0,   "分段1失灵开入异常"},
{105, 0,   0,   "分段2失灵开入异常"},
{106, 0,   0,   "受远方跳闸命令出口"},
{107, 0,   0,   "过负荷保护动作出口"},
{108, 0,   0,   "断路器不一致保护出口"},
{109, 0,   0,   "过流后加速保护出口"},
{110, 0,   0,   "一母失灵开入异常"},
{111, 0,   0,   "二母失灵开入异常"},
{112, 0,   0,   "三母失灵开入异常"},
{113, 0,   0,   "四母失灵开入异常"},
{114, 0,   0,   "重合闸停用跳三相"},
{115, 0,   0,   "两相出口联跳第三相"},
{116, 0,   0,   "联跳三相"},
{117, 0,   0,   "联跳三跳"},
{118, 0,   0,   "死区保护动作"},
{119, 0,   0,   "联跳(联切)出口"},
{120, 0,   0,   "联切1动作"},
{121, 0,   0,   "联切2动作"},
{122, 0,   0,   "过电压保护出口"},
{123, 0,   0,   "投过压保护"},
{124, 0,   0,   "二取二无判据"},
{125, 0,   0,   "二取一无判据"},
{126, 0,   0,   "失灵启动"},
{127, 0,   0,   "失灵保护出口"},
{128, 0,   0,   "重合闸出口"},
{129, 0,   0,   "过流Ⅰ段动作"},
{130, 0,   0,   "过流Ⅱ段动作"},
{131, 0,   0,   "本体轻瓦斯信号"},
{132, 0,   0,   "本体重瓦斯信号"},
{133, 0,   0,   "短引线差动动作"},
{134, 0,   0,   "短引线差动过流Ⅰ段出口"},
{135, 0,   0,   "短引线差动过流Ⅱ段出口"},
{136, 0,   0,   "短引线差动过流Ⅲ段出口"},
{137, 0,   0,   "短引线差动过流Ⅳ段出口"},
{138, 0,   0,   "二取二有判据"},
{139, 0,   0,   "二取一有判据"},
{140, 0,   0,   "过电压就地判据动作"},
{141, 0,   0,   "补偿过电压就地判据动作"},
{142, 0,   0,   "补偿欠电压就地判据动作"},
{143, 0,   0,   "电流变化量就地判据动作"},
{144, 0,   0,   "零负序电流就地判据动作"},
{145, 0,   0,   "低电流就地判据动作"},
{146, 0,   0,   "功率元件就地判据动作"},
{147, 0,   0,   "投Ⅰ母解除电压闭锁"},
{148, 0,   0,   "投Ⅱ母解除电压闭锁"},
{149, 0,   0,   "投Ⅲ母解除电压闭锁"},
{150, 0,   0,   "投Ⅳ母解除电压闭锁"},
{151, 0,   0,   "闭锁先合开入"},
{152, 0,   0,   "高温"},
{153, 0,   0,   "投Ⅰ母运行压板位置异常"},
{154, 0,   0,   "投Ⅱ母运行压板位置异常"},
{155, 0,   0,   "低温"},
{156, 0,   0,   "投Ⅲ母运行压板位置异常"},
{157, 0,   0,   "投Ⅳ母运行压板位置异常"},
{159, 0,   0,   "油位低"},
{160, 0,   0,   "风扇启动"},
{161, 0,   0,   "装置启动"},
{162, 0,   0,   "交流TV断线"},
{163, 0,   0,   "间期TV断线"},
{164, 0,   0,   "冷却器故障跳闸"},
{165, 0,   0,   "一母失灵开入"},
{166, 0,   0,   "二母失灵开入"},
{167, 0,   0,   "三母失灵开入"},
{168, 0,   0,   "四母失灵开入"},
{169, 0,   0,   "母联1失灵开入"},
{170, 0,   0,   "母联2失灵开入"},
{171, 0,   0,   "分段1失灵开入"},
{172, 0,   0,   "分段2失灵开入"},
{173, 0,   0,   "I母TV断线"},
{174, 0,   0,   "II母TV断线"},
{175, 0,   0,   "III母TV断线"},
{176, 0,   0,   "IV母TV断线"},
{177, 0,   0,   "I母电压闭锁开放"},
{178, 0,   0,   "II母电压闭锁开放"},
{179, 0,   0,   "III母电压闭锁开放"},
{180, 0,   0,   "IV母电压闭锁开放"},
{181, 0,   0,   "断路器位置异常"},
{182, 0,   0,   "负序电压动作"},
{184, 0,   0,   "冷却器故障"},
{185, 0,   0,   "匝间保护出口"},
{186, 0,   0,   "A相失灵起动"},
{187, 0,   0,   "B相失灵起动"},
{188, 0,   0,   "C相失灵起动"},
{189, 0,   0,   "零序电流长期起动报警"},
{190, 0,   0,   "整组复归"},
{191, 0,   0,   "装置本机故障"},
{192, 0,   0,   "通信通道异常"},
{193, 0,   0,   "内部随机存储器异常"},
{194, 0,   0,   "数据(外部)随机存储器异常"},
{195, 0,   0,   "程序(只读)存储器出错"},
{196, 0,   0,   "EEPROM出错"},
{197, 0,   0,   "采样数据异常报警"},
{198, 0,   0,   "开关拒动"},
{199, 0,   0,   "液晶显示故障报警"},
{200, 0,   0,   "输出光电隔离击穿"},
{201, 0,   0,   "输出光电隔离无效"},
{202, 0,   0,   "光电隔离失电报警"},
{203, 0,   0,   "控制回路断线"},
{204, 0,   0,   "跳闸压力异常"},
{205, 0,   0,   "合闸压力异常"},
{206, 0,   0,   "电流互感器开路"},
{207, 0,   0,   "压力降低断路器禁止操作"},
{208, 0,   0,   "电流变化量长期启动报警"},
{209, 0,   0,   "运行方式位置异常报警"},
{210, 0,   0,   "TWJ报警"},
{211, 0,   0,   "装置内部通信故障"},
{212, 0,   0,   "跳闸报警"},
{213, 0,   0,   "重喝闸报警"},
{214, 0,   0,   "长期启动报警"},
{215, 0,   0,   "低电压报警"},
{216, 0,   0,   "过电压报警"},
{217, 0,   0,   "零序过电压"},
{218, 0,   0,   "零序过电流"},
{219, 0,   0,   "#1母线接地"},
{220, 0,   0,   "#2母线接地"},
{221, 0,   0,   "系统频率异常"},
{222, 0,   0,   "定值校验出错"},
{223, 0,   0,   "修改定值位置告警"},
{224, 0,   0,   "定值变化(换区)"},
{225, 0,   0,   "长期受信报警"},
{226, 0,   0,   "通道断线报警"},
{227, 0,   0,   "长期差流报警"},
{228, 0,   0,   "跳灭磁开关出口异常"},
{229, 0,   0,   "停机出口异常"},
{230, 0,   0,   "线路过负荷"},
{231, 0,   0,   "Ⅰ段母线电压互感器开路"},
{232, 0,   0,   "Ⅱ段母线电压互感器开路"},
{233, 0,   0,   "过负荷信号"},
{234, 0,   0,   "开关量变位"},
{235, 0,   0,   "闭锁信号动作"},
{236, 0,   0,   "闭锁标识被清除"},
{237, 0,   0,   "跳闸压板投入"},
{238, 0,   0,   "合闸压板投入"},
{239, 0,   0,   "复合电压长期启动"},
{240, 0,   0,   "零序电流长期启动报警"},
{241, 0,   0,   "母线电压互感器开路"},
{242, 0,   0,   "通道1报警"},
{243, 0,   0,   "通道2报警"},
{244, 0,   0,   "出口回路报警"},
{245, 0,   0,   "直流电源异常"},
{246, 0,   0,   "该区定值无效"},
{247, 0,   0,   "失灵跳本开关"},
{248, 0,   0,   "外部跳闸异常"},
{249, 0,   0,   "装置检修"},
{252, 0,   0,   "高频通道异常"},
{253, 0,   0,   "差动保护装置故障告警"},
{254, 0,   0,   "后备保护装置故障告警"},
{0,   0,   0,   "未定义信号"},
};

EVTALM  RCS_C2_Event[] ={
{1,   0,   0,   "保护板闭锁"},
{2,   0,   0,   "保护板报警"},
{3,   0,   0,   "CT报警"},
{4,   0,   0,   "跳闸"},
{5,   0,   0,   "比率差动保护投入"},
{6,   0,   0,   "后备保护投入"},
{7,   0,   0,   "PT断线"},
{8,   0,   0,   "通风起动"},
{9,   0,   0,   "闭锁跳压"},
{10,  0,   0,   "本体重瓦斯跳闸"},
{11,  0,   0,   "有载重瓦斯跳闸"},
{12,  0,   0,   "绕组过温跳闸"},
{13,  0,   0,   "非电量17信号"},
{14,  0,   0,   "非电量18信号"},
{15,  0,   0,   "非电量19信号"},
{16,  0,   0,   "非电量20信号"},
{17,  0,   0,   "发变主保护动作接点开入"},
{18,  0,   0,   "变压器保护动作接点开入"},
{20,  0,   0,   "监视方向闭锁"},
{21,  0,   0,   "有载油位异常信号A相"},
{22,  0,   0,   "有载油位异常信号B相"},
{23,  0,   0,   "有载油位异常信号C相"},
{24,  0,   0,   "有载轻瓦斯信号A相"},
{25,  0,   0,   "有载轻瓦斯信号B相"},
{26,  0,   0,   "有载轻瓦斯信号C相"},
{27,  0,   0,   "本体轻瓦斯信号A相"},
{28,  0,   0,   "本体轻瓦斯信号B相"},
{29,  0,   0,   "本体轻瓦斯信号C相"},
{30,  0,   0,   "绕组温高信号A相"},
{31,  0,   0,   "绕组温高信号B相"},
{32,  0,   0,   "绕组温高信号C相"},
{33,  0,   0,   "CPU采样异常"},
{34,  0,   0,   "装置报警"},
{35,  0,   0,   "装置闭锁"},
{36,  0,   0,   "非电量4延时跳闸A相"},
{37,  0,   0,   "非电量4延时跳闸B相"},
{38,  0,   0,   "非电量4延时跳闸C相"},
{39,  0,   0,   "冷控失电跳闸A相"},
{40,  0,   0,   "冷控失电跳闸B相"},
{41,  0,   0,   "冷控失电跳闸C相"},
{42,  0,   0,   "本体重瓦斯跳闸A相"},
{43,  0,   0,   "本体重瓦斯跳闸B相"},
{44,  0,   0,   "本体重瓦斯跳闸C相"},
{45,  0,   0,   "有载重瓦斯跳闸A相"},
{46,  0,   0,   "有载重瓦斯跳闸B相"},
{47,  0,   0,   "有载重瓦斯跳闸C相"},
{48,  0,   0,   "本体油位异常信号A相"},
{49,  0,   0,   "本体油位异常信号B相"},
{50,  0,   0,   "本体油位异常信号C相"},
{51,  0,   0,   "直流电源消失"},
{52,  0,   0,   "起动CPU启动"},
{53,  0,   0,   "整组起动"},
{54,  0,   0,   "零序保护Ⅰ段出口"},
{55,  0,   0,   "零序保护Ⅱ段出口"},
{56,  0,   0,   "零序保护Ⅲ段出口"},
{57,  0,   0,   "零序保护Ⅳ段出口"},
{58,  0,   0,   "零序不灵敏Ⅰ段出口"},
{59,  0,   0,   "有载油位高信号"},
{60,  0,   0,   "绕组过温信号"},
{61,  0,   0,   "差动速断保护出口"},
{62,  0,   0,   "比率差动保护出口"},
{63,  0,   0,   "高压过流Ⅰ段"},
{64,  0,   0,   "高压过流Ⅱ段"},
{65,  0,   0,   "高压过流Ⅲ段"},
{66,  0,   0,   "低压过流Ⅰ段"},
{67,  0,   0,   "低压过流Ⅱ段"},
{68,  0,   0,   "低压过流Ⅲ段"},
{69,  0,   0,   "压力释放跳闸A相"},
{70,  0,   0,   "压力释放跳闸B相"},
{71,  0,   0,   "压力释放跳闸C相"},
{72,  0,   0,   "非电量2延时跳闸A相"},
{73,  0,   0,   "非电量2延时跳闸B相"},
{74,  0,   0,   "非电量2延时跳闸C相"},
{75,  0,   0,   "非电量9跳闸A相"},
{76,  0,   0,   "非电量9跳闸B相"},
{77,  0,   0,   "非电量9跳闸C相"},
{78,  0,   0,   "绕组过温跳闸A相"},
{79,  0,   0,   "绕组过温跳闸B相"},
{80,  0,   0,   "绕组过温跳闸C相"},
{81,  0,   0,   "修改定值"},
{82,  0,   0,   "DSP出错"},
{83,  0,   0,   "三相不一致接点"},
{84,  0,   0,   "投非全相保护"},
{85,  0,   0,   "投非电量延时保护"},
{86,  0,   0,   "该区定值无效"},
{87,  0,   0,   "跳出口1"},
{88,  0,   0,   "跳出口2"},
{89,  0,   0,   "跳出口3"},
{90,  0,   0,   "过流速断出口"},
{91,  0,   0,   "非电量3延时跳闸A相"},
{92,  0,   0,   "非电量3延时跳闸B相"},
{93,  0,   0,   "非电量3延时跳闸C相"},
{94,  0,   0,   "过流Ⅰ段"},
{95,  0,   0,   "过流Ⅱ段"},
{96,  0,   0,   "过流Ⅲ段"},
{97,  0,   0,   "一侧过流出口"},
{98,  0,   0,   "二侧过流出口"},
{99,  0,   0,   "三侧过流出口"},
{100, 0,   0,   "四侧过流出口"},
{101, 0,   0,   "五侧过流出口"},
{102, 0,   0,   "冷控失电跳闸"},
{103, 0,   0,   "DSP定值校验出错"},
{104, 0,   0,   "DSP采样数据异常"},
{105, 0,   0,   "零序差动保护出口"},
{106, 0,   0,   "零序比率差动保护出口"},
{107, 0,   0,   "工频变化量比率差动保护出口"},
{108, 0,   0,   "间隙零序电压保护出口"},
{109, 0,   0,   "间隙零序电压Ⅰ段保护出口"},
{110, 0,   0,   "间隙零序电压Ⅱ段保护出口"},
{111, 0,   0,   "间隙零序电流保护出口"},
{112, 0,   0,   "间隙零序电流Ⅰ段保护出口"},
{113, 0,   0,   "间隙零序电流Ⅱ段保护出口"},

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =