⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 mcd.h

📁 在Unix平台下完成的电力系统广发使用的IEC103规约的程序
💻 H
字号:
/*
EVTALM MCDEvent[]={
{  0, 0, 0,     "备用1"},
{  1, 0, 0,     "备用2"},
{  2, 0, 0,     "备用3"},
{  3, 0, 0,     "备用4"},
{  4, 0, 0,     "备用5"},
{  5, 0, 0,     "备用6"},
{  6, 0, 0,     "备用7"},
{  7, 0, 0,     "备用8"},
{  8, 0, 0,     "备用9"},
{  9, 0, 0,     "备用10"},
{ 10, 0, 0,     "备用11"},
{ 11, 0, 0,     "备用12"},
{ 12, 0, 0,     "备用13"},
{ 13, 0, 0,     "备用14"},
{ 14, 0, 0,     "备用15"},
{ 15, 0, 0,     "备用16"},
{ 16, 0, 0,     "备用17"},
{ 17, 0, 0,     "备用18"},
{ 18, 0, 0,     "备用19"},
{ 19, 0, 0,     "备用20"},
{ 20, 0, 0,     "备用21"},
{ 21, 0, 0,     "备用22"},
{ 22, 0, 0,     "备用23"},
{ 23, 0, 0,     "备用24"},
{ 24, 0, 0,     "备用25"},
{ 25, 0, 0,     "备用26"},
{ 26, 0, 0,     "备用27"},
{ 27, 0, 0,     "备用28"},
{ 28, 0, 0,     "备用29"},
{ 29, 0, 0,     "备用30"},
{ 30, 0, 0,     "A相跳闸"},
{ 31, 0, 0,     "B相跳闸"},
{ 32, 0, 0,     "C相跳闸"},
{ 33, 0, 0,     "重合闸信号动作"},
{ 34, 0, 0,     "远跳1动作"},
{ 35, 0, 0,     "故障信号载波发送"},
{ 36, 0, 0,     "永久性故障跳闸"},
{ 37, 0, 0,     "重合闸闭锁"},
{ 38, 0, 0,     "过电压跳闸"},
{ 39, 0, 0,     "远跳2动作"},
{ 40, 0, 0,     "线路断线报警"},
{ 41, 0, 0,     "87电流差动保护跳闸"},
{ 42, 0, 0,     "短引线保护跳闸"},
{ 43, 0, 0,     "手合故障跳闸"},
{ 44, 0, 0,     "来自重合闸的三相跳闸"},
{ 45, 0, 0,     "通道故障报警1动作"},
{ 46, 0, 0,     "通道故障报警2动作"},
{ 47, 0, 0,     "PT断线"},
{ 48, 0, 0,     "CT断线"},
{ 49, 0, 0,     "三相跳闸"},
{ 50, 0, 0,     "过流跳闸"},
{ 51, 0, 0,     "距离I段跳闸"},
{ 52, 0, 0,     "距离II段跳闸"},
{ 53, 0, 0,     "距离III段跳闸"},
{ 54, 0, 0,     "接地故障"},
{ 55, 0, 0,     "震荡检测信号动作"},
{ 56, 0, 0,     "方向接地过电流跳闸"},
{ 57, 0, 0,     "方向保护跳闸"},
{ 58, 0, 0,     "备用58"},
{ 59, 0, 0,     "备用59"},
{ 60, 0, 0,     "备用60"},

{  0, 0, 0,     "xx"}

};
*/
EVTALM MCDEvent[]={
{  0, 0, 2,     "备用1"},
{  1, 0, 2,     "备用2"},
{  2, 0, 2,     "备用3"},
{  3, 0, 2,     "备用4"},
{  4, 0, 2,     "备用5"},
{  5, 0, 2,     "备用6"},
{  6, 0, 2,     "备用7"},
{  7, 0, 2,     "备用8"},
{  8, 0, 2,     "备用9"},
{  9, 0, 2,     "备用10"},
{ 10, 0, 2,     "备用11"},
{ 11, 0, 2,     "备用12"},
{ 12, 0, 2,     "备用13"},
{ 13, 0, 2,     "备用14"},
{ 14, 0, 2,     "备用15"},
{ 15, 0, 2,     "备用16"},
{ 16, 0, 2,     "备用17"},
{ 17, 0, 2,     "备用18"},
{ 18, 0, 2,     "备用19"},
{ 19, 0, 2,     "备用20"},
{ 20, 0, 2,     "备用21"},
{ 21, 0, 2,     "备用22"},
{ 22, 0, 2,     "备用23"},
{ 23, 0, 2,     "备用24"},
{ 24, 0, 2,     "备用25"},
{ 25, 0, 2,     "备用26"},
{ 26, 0, 2,     "备用27"},
{ 27, 0, 2,     "备用28"},
{ 28, 0, 2,     "备用29"},
{ 29, 0, 2,     "备用30"},
{ 30, 0, 2,     "A相跳闸"},
{ 31, 0, 2,     "B相跳闸"},
{ 32, 0, 2,     "C相跳闸"},
{ 33, 0, 2,     "备用33"},
{ 34, 0, 2,     "远跳1动作"},
{ 35, 0, 2,     "备用35"},
{ 36, 0, 2,     "备用36"},
{ 37, 0, 2,     "重合闸闭锁"},
{ 38, 0, 2,     "过电压跳闸"},
{ 39, 0, 2,     "备用39"},
{ 40, 0, 2,     "备用40"},
{ 41, 0, 2,     "远跳2动作"},
{ 42, 0, 2,     "87电流差动保护跳闸"},
{ 43, 0, 2,     "通道故障报警2动作"},
{ 44, 0, 2,     "PT断线"},
{ 45, 0, 2,     "三相跳闸"},
{ 46, 0, 2,     "备用46"},
{ 47, 0, 2,     "备用47"},
{ 48, 0, 2,     "备用48"},
{ 49, 0, 2,     "备用49"},
{ 50, 0, 2,     "备用50"},
{ 51, 0, 2,     "备用51"},
{ 52, 0, 2,     "备用52"},
{ 53, 0, 2,     "备用53"},
{ 54, 0, 2,     "线路断线报警"},
{ 55, 0, 2,     "短引线保护跳闸"},
{ 56, 0, 2,     "手合故障跳闸"},
{ 57, 0, 2,     "CT断线报警"},
{ 58, 0, 2,     "备用58"},
{ 59, 0, 2,     "备用59"},
{ 60, 0, 2,     "备用60"},

{  0, 0, 0,     "xx"}

};