📄 flow-receive.1.in
字号:
...\" $Header: /usr/src/docbook-to-man/cmd/RCS/docbook-to-man.sh,v 1.3 1996/06/17 03:36:49 fld Exp $...\"...\" transcript compatibility for postscript use....\"...\" synopsis: .P! <file.ps>...\".de P!\\&..fl \" force out current output buffer\\!%PB\\!/showpage{}def...\" the following is from Ken Flowers -- it prevents dictionary overflows\\!/tempdict 200 dict def tempdict begin.fl \" prolog.sy cat \\$1\" bring in postscript file...\" the following line matches the tempdict above\\!end % tempdict %\\!PE\\!..sp \\$2u \" move below the image...de pF.ie \\*(f1 .ds f1 \\n(.f.el .ie \\*(f2 .ds f2 \\n(.f.el .ie \\*(f3 .ds f3 \\n(.f.el .ie \\*(f4 .ds f4 \\n(.f.el .tm ? font overflow.ft \\$1...de fP.ie !\\*(f4 \{\. ft \\*(f4. ds f4\"' br \}.el .ie !\\*(f3 \{\. ft \\*(f3. ds f3\"' br \}.el .ie !\\*(f2 \{\. ft \\*(f2. ds f2\"' br \}.el .ie !\\*(f1 \{\. ft \\*(f1. ds f1\"' br \}.el .tm ? font underflow...ds f1\".ds f2\".ds f3\".ds f4\".ta 8n 16n 24n 32n 40n 48n 56n 64n 72n .TH "\fBflow-receive\fP" "1".SH "NAME"\fBflow-receive\fP \(em Receive flow data with the NetFlow protocol\&..SH "SYNOPSIS".PP\fBflow-receive\fP [-h] [-A\fI AS0_substitution\fP] [-b\fI big|little\fP] [-C\fI comment\fP] [-d\fI debug_level\fP] [-f\fI filter_fname\fP] [-F\fI filter_definition\fP] [-m\fI privacy_mask\fP] [-o\fI output_file\fP] [-S\fI stat_interval\fP] [-t\fI tag_fname\fP] [-T\fI active_def\fP|\fIactive_def,active_def\fP \&...] [-V\fI pdu_version\fP] [-z\fI z_level\fP] \fIlocalip/remoteip/port\fP .SH "DESCRIPTION".PPThe \fBflow-receive\fP utility is used to receive flows in NetFlowformat\&. When the \fIremoteip\fP is configured only flowsfrom that exporter will be processed, this is the most secure and recommendedconfiguration\&. When the \fIlocalip\fP is configured\fBflow-receive\fP will only process flowssent to the \fI localip\fP IP address\&. If\fIremoteip\fP is 0 (not configured) flows from anysource IP address are accepted\&. Multiple non aggregated PDU versions maybe accepted at once to support Cisco\&'s Catalyst 6500 NetFlowimplementation which exports from both the supervisor and MSFC with thesame IP address and same port but different export versions\&. In this casethe exports will be stored in the format specified by the -V flag orwhichever export type is received first\&. .SH "OPTIONS".IP "-A\fI AS0_substitution\fP" 10Cisco\&'s NetFlow exports represent the local autonomous system as 0 instead ofthe real value\&. This option can be used to replace the 0 in the export withthe a configured value\&. Unfortunately under certain configurations AS 0 canalso represent a cache miss or non forwarded traffic so use with caution\&..IP "-b\fI big\fP|\fIlittle\fP" 10Byte order of output\&..IP "-C\fI Comment\fP" 10Add a comment\&..IP "-d\fI debug_level\fP" 10Enable debugging\&..IP "-f\fI filter_fname\fP" 10Filter list filename\&. Defaults to \fB@localstatedir@/cfg/filter\fP\&..IP "-F\fI filter_definition\fP" 10Select the active definition\&. Defaults to default\&..IP "-h" 10Display help\&..IP "-m\fI privacy_mask\fP" 10Apply \fIprivacy_mask\fP to the source and destination IPaddress of flows\&. For example a privacy_mask of 255\&.255\&.255\&.0 would convertflows with source/destination IP addresses 10\&.1\&.1\&.1 and 10\&.2\&.2\&.2 to 10\&.1\&.1\&.0and 10\&.2\&.2\&.0 respectively\&..IP "-o\fI file\fP" 10Write to \fBfile\fP instead of the standard out\&..IP "-S\fI stat_interval\fP" 10When configured \fBflow-receive\fP will emit a timestampedmessage on stderr every \fIstat_interval\fP minutesindicating counters such as the number of flows received, packets processed,and lost flows\&..IP "-t\fI tag_fname\fP" 10Load tags from \fBtag_name\fP.IP "-T\fI active_def\fP|\fIactive_def,active_def\&.\&.\&.\fP" 10Use \fIactive_def\fP as the active tag definition(s)\&..IP "-V\fI pdu_version\fP" 10Use \fIpdu_version\fP format output\&..PP.nf 1 NetFlow version 1 (No sequence numbers, AS, or mask) 5 NetFlow version 5 6 NetFlow version 6 (5+ Encapsulation size) 7 NetFlow version 7 (Catalyst switches) 8\&.1 NetFlow AS Aggregation 8\&.2 NetFlow Proto Port Aggregation 8\&.3 NetFlow Source Prefix Aggregation 8\&.4 NetFlow Destination Prefix Aggregation 8\&.5 NetFlow Prefix Aggregation 8\&.6 NetFlow Destination (Catalyst switches) 8\&.7 NetFlow Source Destination (Catalyst switches) 8\&.8 NetFlow Full Flow (Catalyst switches) 8\&.9 NetFlow ToS AS Aggregation 8\&.10 NetFlow ToS Proto Port Aggregation 8\&.11 NetFlow ToS Source Prefix Aggregation 8\&.12 NetFlow ToS Destination Prefix Aggregation 8\&.13 NetFlow ToS Prefix Aggregation 8\&.14 NetFlow ToS Prefix Port Aggregation 1005 Flow-Tools tagged version 5.fi.IP "-z\fI z_level\fP" 10Configure compression level to \fI z_level\fP\&. 0 isdisabled (no compression), 9 is highest compression\&. .SH "EXAMPLES".PPListen on port 9800 on any local interface for exports from IP address10\&.0\&.0\&.1, store the exports in \fBflows\fP.PP \fBflow-receive\fP 0/10\&.0\&.0\&.1/9800 > \fBflows\fP.PPListen on port 9800 on any local interface from any IP address, displaythe received flows with flow-print\&..PP \fBflow-receive\fP 0/0/9800 | \fBflow-print\fP.SH "BUGS".PPIt is not currently possible to convert between the aggregated formats (8\&.x)and the non aggregated formats (1,5,6,7)\&..SH "AUTHOR".PPMark Fullmer maf@splintered\&.net.SH "SEE ALSO".PP\fBflow-tools\fP(1)...\" created by instant / docbook-to-man, Mon 14 Oct 2002, 11:40
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -