📄 dtables.a51
字号:
; This module declares the descriptors
;
; This example has one Device Descriptor with:
; One Configuration - single IN port and single OUT port
; One Interface - there is only one method of accessing the ports
; One HID Descriptor - to make PC host software simpler
; One Endpoint Descriptor - for HID Input Reports
; One Report Descriptor - one byte IN and one byte OUT reports
; Multiple Sting Descriptors - to aid the user
;
CSEG
DeviceDescriptor:
DB 18, 1 ; Length, Type
DW 101H ; USB Rev 1.1
DB 0, 0, 0 ; Class, Subclass and Protocol
DB 64 ; EP0 size
DW 4242H, 1, 1 ; Vendor ID, Product ID and Version
DB 1, 2, 0 ; Manufacturer, Product & Serial# Names
DB 1 ; #Configs
ConfigurationDescriptor:
DB 9, 2 ; Length, Type
DB LOW(ConfigLength), HIGH(ConfigLength)
DB 1, 1, 0 ; #Interfaces, Configuration#, Config. Name
DB 10000000b ; Attributes = Bus Powered
DB 50 ; Max. Power is 50x2 = 100mA
InterfaceDescriptor:
DB 9, 4 ; Length, Type
DB 0, 0, 1 ; No alternate setting, HID uses EP1
DB 3 ; Class = Human Interface Device
DB 0, 0 ; Subclass and Protocol
DB 0 ; Interface Name
HIDDescriptor:
DB 9, 21H ; Length, Type
DB 0, 1 ; HID Class Specification compliance
DB 0 ; Country localization (=none)
DB 1 ; Number of descriptors to follow
DB 22H ; And it's a Report descriptor
DB LOW(ReportLength), HIGH(ReportLength)
EndpointDescriptor:
DB 7, 5 ; Length, Type
DB 10000001b ; Address = IN 1
DB 00000011b ; Interrupt
DB 64, 0 ; Maximum packet size (this example only uses 1)
DB 10 ; Poll every 100 msec
ConfigLength EQU $ - ConfigurationDescriptor
ReportDescriptor: ; Generated with HID Tool, copied to here
DB 6, 0, 0FFH ; Usage_Page (Vendor Defined)
DB 9, 1 ; Usage (I/O Device)
DB 0A1H, 1 ; Collection (Application)
DB 19H, 1 ; Usage_Minimum
DB 29H, 2 ; Usage_Maximum
DB 15H, 0 ; Logical_Minimum (0)
DB 25H, 1 ; Logical_Maximum (1)
DB 75H, 8 ; Report_Size (8)
DB 95H, 1 ; Report_Count (1)
DB 81H, 2 ; Input (Data,Var,Abs)
DB 19H, 1 ; Usage_Minimum
DB 29H, 2 ; Usage_Maximum
DB 91H, 2 ; Output (Data,Var,Abs)
DB 0C0H ; End_Collection
ReportLength EQU $-ReportDescriptor
String0: ; Declare the UNICODE strings
DB 4, 3, 9, 4 ; Only English language strings supported
String1: ; Manufacturer
DB (String2-String1),3 ; Length, Type
DB "U",0,"S",0,"B",0," ",0,"D",0,"e",0,"s",0,"i",0,"g",0,"n",0," ", 0
DB "B",0,"y",0," ",0,"E",0,"x",0,"a",0,"m",0,"p",0,"l",0,"e",0
String2: ; Product Name
DB (EndOfDescriptors-String2),3
DB "S",0,"e",0,"r",0,"i",0,"a",0,"l",0,"1",0
EndOfDescriptors:
DW 0 ; Backstop for String Descriptors