Interrupt List, part 13 of 18
Copyright (c) 1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999 Ralf Brown
--------V-2FAD00-----------------------------
INT 2F U - DOS 3.3+ DISPLAY.SYS internal - INSTALLATION CHECK
	AX = AD00h
Return: AL = FFh if installed
	    BX = ??? (0100h for MS-DOS 3.3+)
Note:	DOS 5+ DISPLAY.SYS chains to previous handler if AL is not one of the
	  subfunctions listed here
SeeAlso: AX=AD01h"DISPLAY",AX=AD02h"DISPLAY"
--------O-2FAD00-----------------------------
INT 2F U - DR DOS 3.41-5.0, Novell DOS 7 KEYB - INSTALLATION CHECK
	AX = AD00h
Return: AX = FFFFh if installed
	flags destroyed
Note:	the Novell DOS 7 KEYB driver only checks AL to determine whether it
	  is already installed
SeeAlso: AX=AD80h"Novell"
--------V-2FAD01-----------------------------
INT 2F U - DOS 3.3+ DISPLAY.SYS internal - SET ACTIVE CODE PAGE
	AX = AD01h
	BX = new code page (see #01757 at INT 21/AX=6602h)
Return: CF clear if successful
	    AX = 0001h
	CF set on error (unsupported code page)
	    AX = 0000h
SeeAlso: AX=AD02h"DISPLAY"
--------O-2FAD01-----------------------------
INT 2F U - DR DOS 3.41,5.0 KEYB - GET CONFIGURATION
	AX = AD01h
Return: BX = current code page (see #01757 at INT 21/AX=6602h)
	CX = current keyboard layout (0100h = US, 0102h = foreign)
	ES = resident code segment
SeeAlso: AX=AD01h"Novell",AX=AD00h"KEYB",AX=AD02h"KEYB",AX=AD83h"KEYB"
--------O-2FAD01-----------------------------
INT 2F U - Novell DOS 7 KEYB - GET/SET??? CONFIGURATION
	AX = AD01h
	CX = ??? (0000h)
Return: AX = FFFFh if Novell DOS 7 KEYB installed
	BX = current code page (see #01757 at INT 21/AX=6602h)
	CX = current keyboard layout (0100h = US, 0102h = foreign)
	ES = resident code segment
SeeAlso: AX=AD01h"DR DOS",AX=AD00h"KEYB",AX=AD02h"KEYB",AX=AD83h"KEYB"
--------V-2FAD02-----------------------------
INT 2F U - DOS 3.3+ DISPLAY.SYS internal - GET ACTIVE CODE PAGE
	AX = AD02h
Return: CF set if code page never set
	    AX = 0001h
	    BX = FFFFh (assume first hardware code page)
	CF clear if successful
	    BX = current code page (see #01757 at INT 21/AX=6602h)
SeeAlso: AX=AD01h"DISPLAY",AX=AD03h
--------O-2FAD02-----------------------------
INT 2F U - Novell DOS 7 KEYB - ???
	AX = AD02h
	DX = ??? (0000h)
Return: AX = FFFFh if installed
	flags destroyed
SeeAlso: AX=AD01h"KEYB"
--------V-2FAD03-----------------------------
INT 2F U - DOS 3.3+ DISPLAY.SYS internal - GET CODE PAGE INFORMATION
	AX = AD03h
	ES:DI -> buffer for code page information (see #02971)
	CX = size of buffer in bytes
Return: CF set if buffer too small
	CF clear if successful
	    ES:DI buffer filled
SeeAlso: AX=AD01h,AX=AD02h

Format of DOS 5.0-6.0 DISPLAY.SYS code page information:
Offset	Size	Description	(Table 02971)
 00h	WORD	number of software code pages
 02h	WORD	??? (0003h)
 04h	WORD	number of hardware code pages
 06h  N WORDs	hardware code page numbers (see #01757 at INT 21/AX=6602h)
      N WORDs	software (prepared) code pages (FFFFh if not yet prepared)
--------V-2FAD04-----------------------------
INT 2F U - DOS 4.x only DISPLAY.SYS internal - ???
	AX = AD04h
	???
Return: ???
--------V-2FAD10-----------------------------
INT 2F U - DOS 4.x DISPLAY.SYS internal - INSTALLATION CHECK???
	AX = AD10h
	???
Return: AX = FFFFh
	BX = ??? (0100h in PC-DOS 4.01)
--------V-2FAD10-----------------------------
INT 2F U - DOS 5+ DISPLAY.SYS internal - ???
	AX = AD10h
	???
Return: CF clear if successful
	CF set on error
Note:	this function is a NOP if the active code page has never been set
	  (AX=AD02h returns BX=FFFFh); its purpose otherwise is not known
--------V-2FAD40-----------------------------
INT 2F - DOS 4.0+ - ???
	AX = AD40h
	DX = ???
	???
Return: ???
Note:	called by PC-DOS 4.01 PRINT.COM
--------K-2FAD80-----------------------------
INT 2F u - MS-DOS 3.3+ KEYB.COM internal - INSTALLATION CHECK
	AX = AD80h
Return: AL = FFh if installed
	    BX = version number (BH = major, BL = minor)
	    ES:DI -> internal data (see #02972)
	    AH destroyed (set to FFh by some implementations/versions)
Notes:	MS-DOS 3.30, PC-DOS 4.01, MS-DOS 5.00, and MS-DOS 6.22 all report
	  version 1.00.
	this function was undocumented prior to the release of DOS 5.0
	most versions of KEYB completely replace the BIOS INT 09 handler, but
	  Novell DOS's KEYB partially uses the BIOS code and thus continues
	  to chain to the original INT 09 at times
	some utilities check for AX=FFFFh on return
SeeAlso: AX=AD80h"Novell",AX=AD81h,AX=AD82h,AX=AD83h

Format of KEYB internal data:
Offset	Size	Description	(Table 02972)
 00h	DWORD	original INT 09
 04h	DWORD	original INT 2F
 08h	DWORD	unused (0) original INT 16 in older KEYB versions???
 0Ch	WORD	flags A (see #02973)
 0Eh	WORD	flags B (see #02974)
 10h	BYTE	flags??? (bit1 used)
 11h	BYTE	???
 12h  4 BYTEs	???
 16h  2 BYTEs	country ID letters, default is "US"
 18h	WORD	current code page (see #01757 at INT 21/AX=6602h)
---DOS 3.3---
 1Ah	WORD	pointer to first item in list of code page tables???
 1Ch	WORD	pointer to ??? item in list of code page tables
 1Eh  2 BYTEs	unused???
 20h	WORD	pointer to key translation data (see #02976)
 22h	WORD	pointer to last item in code page table list (see #02975)
 24h  9 BYTEs	???
---DOS 4.01---
 1Ah  2 BYTEs	???
 1Ch	WORD	pointer to first item in list of code page tables???
 1Eh	WORD	pointer to ??? item in list of code page tables
 20h 2 BYTEs	unused???
 22h	WORD	pointer to key translation data (see #02976)
 24h	WORD	pointer to last item in code page table list (see #02975)
 26h  9 BYTEs	???
---DOS 6.22--- (checked out with 6.22, but might be earlier)
 1Ah  2 BYTEs	???
 1Ch	WORD	pointer to current (first???) item in list of code page tables
		(corresponding to codepage indicated at offset 18h)
		(initial value is FFFFh)
 1Eh	WORD	pointer to (entry to) list of code page tables (see #02975)
		If not FFFFh, INT 2F/AX=AD81h scans this list of code page
		  tables until the requested code page was found in list or
		  end of table was reached (FFFFh). If found, offsets 18h and
		  1Ch will be changed to requested new code page. If not found,
		  it returns with AX=0001h 'code page not supported').
 20h	WORD	unused??? (initial value: FFFFh)
 22h	WORD	pointer to key translation data (see #02455)
 24h	WORD	pointer to last item in code page table list (see #02454)
 26h	WORD	CAPSLock/ShiftLock management flags??? (0)
		Note:	It appears that none of the bits is ever set inside
			  KEYBs code!
			  The following is guesswork:
		bit15: =1: With country specific keyboard mapping (<Ctrl>+
			  <Alt>+<F2>) active, <CapsLock> works as CAPSLock
			  instead of ShiftLock??? Pressing a key in first row
			  resets CapsLock???
			  (Effective only on PC Convertible or with Enhanced
			  keyboard).
		bit14-10:  unused (0)
		bit 9: =1: With country specific keyboard mapping active:
			  some kind of temporary (table) shift???
		bit 8-0: unused (0)
 28h	BYTE	unused (0)
 29h	BYTE	make code xx for <Ctrl>+<Alt>+<xx> to set keyboard mapping
		  to US-layout (default is 3Bh=<F1>???)
		  (see INT 2F/AX=AD82h,INT 2F/AX=AD83h)
 2Ah	BYTE	make code yy for <Ctrl>+<Alt>+<yy> to set keyboard mapping
		  to country specific layout (default is 3Ch=<F2>???),
		  (see INT 2F/AX=AD82h,INT 2F/AX=AD83h)
 2Bh 16 BYTEs	unused (0) ???
Note:	at least in MS-DOS v6.22, the signature "SHARED DATA" immediately
	  precedes this structure

Bitfields for MS-DOS v6.22 KEYB flags A:
Bit(s)	Description	(Table 02973)
 15	unused??? (0)
 14	set on machine with BIOS machine type FBh or FEh/FFh without enh kbd
 13	not FAh: ???
 12	set on start of machine detection, cleared on machine types F9h, FBh,
	  FEh, FFh
 11	not FAh: ???
	(on ATs: override bit12 NOT to set NumLock on)
 10	set on machine type F9h
 9	unused??? (0)
 8	unused??? (0)
 7	used by INT 09, but never set!
	=1: after keyboard self test resulting AAh, INT 09 handler will (re)set
	      keyboard code-set 1 and temporarily disable a PS/2 mouseport.
 6	used by INT09, but never set!
	=1: after keyboard self test resulting AAh, INT 09 handler will (re)set
	      keyboard code-set 1 and temporarily disable a PS/2 mouseport.
 5	set for JP, KO, PR, TA layouts during installation???
	=1: some special codepage (>932???) management???
 4-0	unused??? (0)
SeeAlso: #02974,MEM F000h:FFFEh,INT 15/AH=C0h

Bitfields for MS-DOS v6.22 KEYB flags B:
Bit(s)	Description	(Table 02974)
 15	INT 16/AH=1xh supported (INT 16h/AH=92h call returns AH<=80h)
	if clear, extended keyboard scan codes are immediately discarded
 14	INT 16/AH=2xh supported (INT 16h/AH=A2h call returns AH<=80h)
 13	unused (0)
 12	network installed (INT 2F/AX=B800h)
 11	original IBM PC (BIOS date 1981)
 10	PC or PC/XT (BIOS machine type byte of FBh or FEh)
 9	PC Convertible (BIOS machine type byte of F9h); use INT 15/AX=4104h
 8	unused (0)
 7	IBM PS/2 model 30 (BIOS machine type byte of FAh)
 6	IBM AT (BIOS machine type FCh)
 5	IBM PS/2 (BIOS machine type F8h)
 4	PS/2 and unknown only: non-standard 8042 reported by INT 15/AH=C0h
	=1: after keyboard self test resulting AAh, INT 09 handler will (re)set
	      keyboard code-set 1 and temporarily disable a PS/2 mouseport.
 3	temporary flag???
 2-0	???
SeeAlso: #02972,#02973

Format of code page table list entries:
Offset	Size	Description	(Table 02975)
 00h	WORD	pointer to next item, FFFFh = last
 02h	WORD	code page (see #01757 at INT 21/AX=6602h)
 04h  2 BYTEs	???

Format of KEYB translation data:
Offset	Size	Description	(Table 02976)
 00h	WORD	size of data in bytes, including this word
 02h N-2 BYTEs	???
--------K-2FAD80-----------------------------
INT 2F u - Novell DOS 7 KEYB.COM - INSTALLATION CHECK
	AX = AD80h
Return: AX = FFFFh if installed
	    CX = Novell DOS KEYB version number (CL = major, CH = minor)
	    DX = current keyboard codepage
	    ES:DI -> internal data and tables (ES=FFFEh if KEYB in HMA)
	flags destroyed
Notes:	versions: v2.08 (original ship 4/94), v2.09 (Update 10, 11/18/94),
	  v2.10 (Update 12, 2/22/95), v2.11 (Update 13, 5/8/95),
	  v2.12 (Update 14, 7/31/95)
	although the installation check is via this INT 2F call, Novell DOS 7's
	  KEYB has no known INT 2F entry point!	 Presumably, the handler is
	  either coded in the kernel or reached via a FAR JMP from the kernel
SeeAlso: AX=AD80h"MS-DOS"
--------K-2FAD81-----------------------------
INT 2F - DOS 3.3+ KEYB.COM - SET KEYBOARD CODE PAGE
	AX = AD81h
	BX = code page (see #01757 at INT 21/AX=6601h)
Return: CF set on error
	    AX = 0001h (code page not available)
	CF clear if successful
Notes:	called by DISPLAY.SYS
	this function was undocumented prior to the release of DOS 5.0
SeeAlso: AX=AD80h,AX=AD82h
--------K-2FAD82-----------------------------
INT 2F - DOS 3.3+ KEYB.COM - SET KEYBOARD MAPPING
	AX = AD82h
	BL = new state
	    00h US keyboard (Control-Alt-F1)
	    FFh foreign keyboard (Control-Alt-F2)
Return: CF set on error (BL not 00h or FFh)
	CF clear if successful
Note:	this function was undocumented prior to the release of DOS 5.0
SeeAlso: AX=AD80h,AX=AD81h,AX=AD83h
--------K-2FAD83-----------------------------
INT 2F - DOS 5+ KEYB.COM - GET KEYBOARD MAPPING
	AX = AD83h
Return: BL = current state
	    00h US keyboard
	    FFh foreign keyboard
SeeAlso: AX=AD82h
--------l-2FAE00-----------------------------
INT 2F U - DOS 3.3+ internal - INSTALLABLE COMMAND - INSTALLATION CHECK
	AX = AE00h
	DX = magic value FFFFh
	CH = FFh
	CL = length of command line tail (4DOS v4.0)
	DS:BX -> command line buffer (see #02977)
	DS:SI -> command name buffer (see #02978)
	DI = 0000h (4DOS v4.0)
Return: AL = FFh if this command is a TSR extension to COMMAND.COM
	AL = 00h if the command should be executed as usual
Notes:	This call provides a mechanism for TSRs to install permanent
	  extensions to the command repertoire of COMMAND.COM.	It appears
	  that COMMAND.COM makes this call before executing the current
	  command line, and does not execute it itself if the return is FFh.
	APPEND hooks this call, to allow subsequent APPEND commands to
	  execute without re-running APPEND
SeeAlso: AX=AE01h

Format of COMMAND.COM command line buffer:
Offset	Size	Description	(Table 02977)
 00h	BYTE	max length of command line, as in INT 21/AH=0Ah
 01h	BYTE	count of bytes to follow, excluding terminating 0Dh
      N BYTEs	command line text, terminated by 0Dh

Format of command name buffer:
Offset	Size	Description	(Table 02978)
 00h	BYTE	length of command name
 01h  N BYTEs	uppercased command name (blank-padded to 11 chars by 4DOS v4)
--------l-2FAE01-----------------------------
INT 2F U - DOS 3.3+ internal - INSTALLABLE COMMAND - EXECUTE
	AX = AE01h
	DX = magic value FFFFh
	CH = 00h
	CL = length of command name (4DOS v4.0)
	DS:BX -> command line buffer (see #02977)
	DS:SI -> command name buffer (see #02978)
Return: DS:SI buffer updated
	  if length byte is nonzero, the following bytes contain the uppercase
	  internal command to execute and the command line buffer contains the
	  command's parameters (the first DS:[SI] bytes are ignored)
Notes:	this call requests execution of the command which a previous call to
	  AX=AE00h indicated was resident
	APPEND hooks this call
BUG:	Novell DOS 7.0's COMMAND.COM (prior to Update 12) will attempt to run
	  a disk program with the indicated name even if the returned length
	  byte is zero, because the register used to flag this case is
	  clobbered without first checking it.	The workaround is to set the
	  command name buffer to "REM" followed by enough blanks to pad out
	  the original command's length, which will also work with MS-DOS 6.
	  (from padgett@tccslr.dnet.mmc.com)
SeeAlso: AX=AE00h
--------O-2FAF00-----------------------------
INT 2F - WinDOS v2.11 - INSTALLATION CHECK
	AX = AF00h
Return: AL = FFh if installed
Program: WinDOS is a DOS clone (claimed to be mostly MS-DOS 5.0 API compatible)
	  written by Heiko Goemann
SeeAlso: AX=AF01h"WinDOS",INT 21/AH=30h
----------2FAF00-----------------------------
INT 2F U - ???
	AX = AF00h
	???
Return: AX = 0000h if interface supported
SeeAlso: AX=AF02h,AX=AF03h,AX=AF04h,AX=AF13h,AX=AF30h