		ES:DI -> buffer for ??? (60 bytes total data)
		Return: CX = number of bytes actually returned
		Note:	returns the array storing the values set with AX=2301h
		Format of one entry in array:
		Offset	Size	Description
		 00h	BYTE	??? (BL from subfn 01h)
		 01h	WORD	??? (CX from subfn 01h)
		 03h	BYTE	??? (BH from subfn 01h)
		 04h	WORD	??? (DX from subfn 01h)
	    AL = 03h set ??? name/path
		ES:DI -> buffer containing ASCIZ ???
	    AL = 04h get ???
		ES:DI -> buffer for ASCIZ ???
	    Note: the ASCIZ string for subfunctions 03h and 04h does not appear
		to be used by 386MAX, and may serve merely for communication
		between two other Qualitas programs
	AH = 24h (v7.00) high memory control
	    AL = 00h get high memory state
		Return: BX = current state
			    00h high memory removed from DOS memory chain
			    01h high memory included in DOS memory chain
	    AL = 01h set high memory state
		BX = new state
		    00h high memory removed from DOS memory chain
		    01h high memory included in DOS memory chain
		    else
			Return: ??? (error, but return varies according to ???)
	AH = 25h (v7.00) remove high RAM from DOS memory chain
	AH = 26h (v7.00) ???
	    BX = ???
	    CX = ???
	    SI = ???
	    DI = ???
	    Return: AH = status
		    BX = ???
		    CX = ???
	AH = 27h (v7.00) ???
	    AL = 00h get ???
		Return: BX = number of paragraphs for ???
	    AL = 01h ???
		BX = ???
		ES??? = ???
	    AL = 02h ???
		???
	    AL = 03h ???
		CX = ???
		DX = ???
		ES??? = ???
		Return: ???
	AH = 28h (v7.00) get ???
		Return: AH = status (00h,8Fh) (see #03648 at INT 67/AH=40h)
			if AH=00h,
			    CX = ???
			    DX = ???
	AH = 29h (v7.00) get ???
		Return: AX = ???
	AH = 40h-5Dh EMS services (see INT 67/AH=40h, etc.)
	AH = DEh VCPI services (see INT 67/AX=DE00h, etc.)
Return: AH = status (as for EMS INT 67 calls)
	    00h successful
	    80h internal error
	    81h hardware malfunction
	    83h invalid handle
	    84h	undefined function
	    8Ah invalid logical page nuber
	    8Bh illegal physical page number
	    8Fh undefined subfunction
	    A4h access denied
	    etc.
	STACK popped (value placed in DX if no specific return value for DX)

Format of 386MAX memory speed record:
Offset	Size	Description	(Table 01482)
 00h	DWORD	page table entry for 4K page
 04h	WORD	number of microticks (840ns units) required for REP LODSD of
		  entire 4K page

Format of 386MAX memory info [array]:
Offset	Size	Description	(Table 01483)
 00h	DWORD	linear start address
 04h	DWORD	size in bytes
 08h	WORD	XMS handle (if next byte = 04h)
		??? (if next byte = 05h)
		??? (if next byte = 06h)
		??? (if next byte = 13h)
		??? (if next byte = 14h)
		??? (if next byte = 15h)
		??? (if next byte = 23h)
		??? (if next byte = 24h)
		??? (if next byte = 26h)
		else unused
 0Ah	BYTE	type
		00h = ???, 01h = VDISK,
		02h = INT 15h extended memory, 03h = ??? extended,
		04h = XMS handle's memory, 05h = ???, 06h = ???, 07h = ???,
		08h = ???, 09h = ???, 0Ah = ???, 0Bh = ???,
		11h = ???, 12h = ???, 14h = ???, 15h = ???,
		19h = ???, 1Ah = ???, 1Bh = ???,
		1Ch = ???, 1Dh = ???, 1Eh = ???, 1Fh = ???,
		20h = ???, 21h = ???, 23h = ???, 24h = ???,
		26h = ???
 0Bh	BYTE	??? (00h for types 00h-03h, 07h-0Bh, 19h-21h;
		     80h for types 04h/13h-15h/23h-26h;
			??? for type 05h)
--------V-214402-----------------------------
INT 21 - PGS1600.DEV - IOCTL - GET CONFIGURATION INFO
	AX = 4402h
	BX = file handle for device "PGS1600$"
	CX = 0018h (size of buffer)
	DS:DX -> configuration buffer (see #01484)
Return: CF clear if successful
	    buffer filled
	    AX = number of bytes actually copied
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
Program: PGS1600.DEV is a device driver for the Cornerstone Technology PG1600
	  display adapter, which provides a 1600x1200 monochrome display as
	  well as one of two emulations, MDA or CGA.
SeeAlso: AX=4403h"PGS1600"

Format of PGS1600.DEV configuration information:
Offset	Size	Description	(Table 01484)
 00h	WORD	version (high byte = major, low byte = minor)
 02h	WORD	board initialisation mode
 04h	WORD	board I/O address
		03D0h CGA emulation
		03B0h MDA emulation
		0390h no emulation
		0350h no emulation, alternate
 06h	WORD	emulation buffer segment
		B800h	CGA emulation
		B000h	MDA emulation
		0000h	no emulation
 08h	WORD	PG1600 graphics buffer segment
 0Ah	WORD	number of bytes between consecutive graphic rows
 0Ch	WORD	horizontal pixel size
 0Eh	WORD	vertical pixel size
 10h	WORD	horizontal dots per inch
 12h	WORD	vertical dots per inch
 14h	WORD	graphics buffer bits per pixel
 16h	WORD	monitor bits per pixel
--------N-214402-----------------------------
INT 21 - PC/TCP IPCUST.SYS - RESET CONFIGURATION DATA READ POINTER
	AX = 4402h
	BX = file handle referencing device "$IPCUST"
	CX, DS:DX ignored
Return: CF clear if successful
	    AX destroyed
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
Notes:	there are a total of 378h bytes of configuration data for IPCUST.SYS
	  version 2.05.	 If less than the entire data is read or written,
	  the next read/write continues where the previous one ended; this
	  call and AX=4403h both reset the location at which the next
	  operation starts to zero
	v2.1+ uses a new configuration method, but allows the installation
	  of IPCUST.SYS for backward compatibility with other software which
	  must read the PC/TCP configuration
SeeAlso: AH=3Fh"IPCUST",AH=40h"IPCUST",AX=4403h"IPCUST"
--------N-214402-----------------------------
INT 21 - WORKGRP.SYS - GET API ENTRY POINT
	AX = 4402h
	BX = file handle for device "NET$HLP$"
	CX = 0008h
	DS:DX -> buffer for entry point record (see #01485)
Return: CF clear if successful
	    AX = number of bytes actually read
	CF set on error
	    AX = error code
Program: WORKGRP.SYS is the portion of Microsoft's Workgroup Connection which
	  permits communication with PCs running Windows for Workgroups or
	  LAN Manager
SeeAlso: AH=3Fh"WORKGRP.SYS"

Format of WORKGRP.SYS entry point record:
Offset	Size	Description	(Table 01485)
 00h	WORD	3633h  \ signature???
 02h	WORD	EF6Fh  /
 04h	DWORD	address of entry point (see #01486)
Note:	first four bytes of buffer must be 6Fh E9h 33h 36h on entry when using
	  IOCTL rather than READ to get the entry point record

(Table 01486)
Call WORKGRP entry point with:
	STACK:	WORD	function number (0000h-0009h)
Return: STACK unchanged
SeeAlso: #01487,#01488,#01489,#01490,#01491,#01492,#01493,#01494

(Table 01487)
Call WORKGRP function 00h with:
	STACK:	WORD	0000h (function "get ???")
Return: DX:AX -> data table

(Table 01488)
Call WORKGRP function 01h with:
	STACK:	WORD	0001h (function "hook ???")
Return: STACK:	DWORD	pointer to ???
		WORD	0001h (function number)

(Table 01489)
Call WORKGRP function 02h with:
	STACK:	WORD	0002h (function "unhook ???")
	???
Return: ???

(Table 01490)
Call WORKGRP function 03h with:
	STACK:	WORD	0003h (function "reenable printer port")
		WORD	LPT port number
Return: ???

(Table 01491)
Call WORKGRP function 04h with:
	STACK:	WORD	0004h (function "disable printer port")
		WORD	LPT port number
Return: ???

(Table 01492)
Call WORKGRP function 05h with:
	STACK:	WORD	0005h (function "???")
		???
Return: ???

(Table 01493)
Call WORKGRP function 06h with:
	STACK:	WORD	0006h (function "???")
Return: STACK unchanged
	AX = 0000h
	DX = 0000h

(Table 01494)
Call WORKGRP functions 07h-09h with:
	STACK:	WORD	0007h-0009h (NOP functions)
Return: STACK unchanged
	AX = 0001h
	DX = 0000h
--------N-214402-----------------------------
INT 21 - 10NET v5.0 - 10BEUI.DOS - API
	AX = 4402h
	BX = file handle referencing device "10BEUI$"
	DS:DX -> parameter record (see #01495)
	CX ignored
Return: CF clear if successful
	    AX destroyed
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
SeeAlso: AX=4402h"10MEMMGR",INT 6F/AH=00h"10NET"

Format of 10NET 10BEUI.DOS parameter record:
Offset	Size	Description	(Table 01495)
 00h	WORD	000Ah (function number???)
 02h	WORD	???
 04h	DWORD	pointer to buffer for ???
 08h  4 BYTEs	???
 0Ch	WORD	transfer size
--------N-214402-----------------------------
INT 21 - 10NET v5.0 - 10MEMMGR.SYS - API
	AX = 4402h
	BX = file handle referencing device "MEMMGR0$"
	DS:DX -> 6-byte buffer for interface info (see #01496)
	CX ignored
Return: CF clear if successful
	    AX destroyed
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
SeeAlso: AX=4402h"10BEUI",INT 6F/AH=00h"10NET"

Format of 10NET 10MEMMGR.SYS interface info:
Offset	Size	Description	(Table 01496)
 00h	DWORD	address of entry point (see #01497)
 04h	WORD	version (0500h for v5.00)

(Table 01497)
Call 10NET 10MEMMGR.SYS entry point with:
	AL = 01h ???
	    BX = ???
	    Return: CF clear if successful
		    CF set on error
			AX = error code
	AL = 02h ???
	    ???
	AL = 03h ???
	    ???
	AL = 04h set/restore memory allocation strategy
	    BX = subfunction
		0000h set strategy
		0001h restore strategy
	    Return: CF clear if successful
		    CF set on error (if function disabled)
		    various registers destroyed
	AL = other
	    Return: CF set
		    AX = 0000h
		    BL = 01h
--------V-214402-----------------------------
INT 21 - Compaq AG1024.SYS - RGDI - GET DRIVER LOCATION
	AX = 4402h
	BX = file handle for device "$$$$RGDI"
	CX = 0006h (size of returned data)
	DS:DX -> location record (see #01498)
Return: CF clear if successful
	    buffer filled
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
Program: AG1024.SYS is a device driver for the Advanced Graphics 1024 adapter
SeeAlso: AX=4403h"RGDI"

Format of Compaq AG1024.SYS location record:
Offset	Size	Description	(Table 01498)
 00h	WORD	signature 55AAh
 02h	WORD	segment of ???
 04h	WORD	segment of device driver's code
--------N-214402-----------------------------
INT 21 - FTPSOFT.DOS v3.1 - GET ???
	AX = 4402h
	BX = file handle for device "FTPSOFT$"
	CX = size of buffer
	DS:DX -> buffer for data (see #01499)
Return: CF clear if successful
	    buffer filled
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
Program: FTPSOFT.DOS is a device driver for Protocol Manager support from
	   FTP Software, Inc.
SeeAlso: AH=3Fh"PC/TCP",AX=4402h"NDIS"

Format of FTPSOFT.DOS data:
Offset	Size	Description	(Table 01499)
 00h	WORD	(call) BA98h (if different, no data returned)
 02h	DWORD	-> NDIS common characteristics table
		  (see #01435 at AX=4402h"NDIS")
 06h	DWORD	(call) -> new dispatch table (see #01437 at AX=4402h"NDIS")
 0Ah	DWORD	-> 28-byte buffer for ??? data
 0Eh	DWORD	???
 12h	DWORD	-> FAR function to reset dispatch jump table to defaults
 16h	BYTE	???
Note:	the addresses in the new dispatch table are copied into an internal
	  jump table which may be reset by calling the function pointed at by
	  offset 12h
--------n-214402-----------------------------
INT 21 U - PenDOS PENDEV.SYS - GET ENTRY POINTS
	AX = 4402h
	BX = file handle for device "$$PENDOS" or "$$PD_REG"
	CX = size of buffer (4 for $$PENDOS and a 4,8,12, or 16 for $$PD_REG)
	DS:DX -> buffer for entry point record (see #01500)
Return: CF clear if successful
	    buffer filled
	CF set on error
	    AX = error code (01h,05h,06h,0Dh) (see #01680 at AH=59h/BX=0000h)
Program: A limited version of PenDOS by Communication Intelligence Corporation,
	  which provides pen capability to keyboard-based programs, is bundled
	  with IBM DOS 6.1
SeeAlso: AX=4403h"PENDEV.SYS"

Format of PENDEV.SYS entry point record:
Offset	Size	Description	(Table 01500)
 00h	DWORD	-> array of jumps
 04h	WORD	offset of function to retrieve entry point (see #01501)
 06h  2 BYTEs	signature "Pe"
 08h	WORD	offset of function to set entry point (see #01502)
 0Ah  2 BYTEs	signature "nD"
 0Ch	WORD	offset of function to clear entry point (see #01503)
 0Eh	WORD	signature "OS"

(Table 01501)
Call PENDEV.SYS function to retrieve entry point with:
	AX = index of entry point (0-9)
Return: CF clear if successful
	    DX:AX -> desired entry point
	CF set on error (AX out 