📄 rfc1230.txt
字号:
dot4StandardRevision INTEGER } dot4IfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies theTransmission Working Group [Page 6]RFC 1230 IEEE 802.4 MIB May 1991 802.4 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface." ::= { dot4Entry 1 } dot4Options OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The optional parts of the 802.4 specification which are in use by this station. The options of the 802.4 specification are represented by the following values: 1 - Priority 2 - Request-With-Response The value of this object is given by the sum of the above representations for those options in use on this interface. The value zero indicates that no options are in use." ::= { dot4Entry 2 } dot4State OBJECT-TYPE SYNTAX INTEGER { other(1), offline(2), outOfRing(3), enteringRing(4), inRing(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the 802.4 interface. The value of other(1) is used if the state is unknown (e.g., due to an error condition)." ::= { dot4Entry 3 } dot4Commands OBJECT-TYPE SYNTAX INTEGER { no-op(1), enterRing(2),Transmission Working Group [Page 7]RFC 1230 IEEE 802.4 MIB May 1991 exitRing(3), reset(4), initialize(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object causes the station to change the state of the interface as indicated by the specified value. An initialize(5) command causes the interfaceto load its operational parameters from its initialization parameters; the value of dot4InitInRingDesired determines whether the station tries to enter the logical ring immediately. Note that the 802.4 specification suggests a station remain Offline after a 'remote Network Management' reset(4), until a 'local Network Management' initialize(5) is performed. Setting this object to a value of no-op(1) has no effect. When read, this object always has the value no-op(1)." ::= { dot4Entry 4 } dot4MacAddrLen OBJECT-TYPE SYNTAX INTEGER { sixteenBit(1), forty-eightBit(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the size of MAC addresses interpreted by this station." ::= { dot4Entry 5 } dot4NextStation OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of this station's successor in the logical ring." ::= { dot4Entry 6 }Transmission Working Group [Page 8]RFC 1230 IEEE 802.4 MIB May 1991 dot4PreviousStation OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The source MAC address of the last token addressed to this station." ::= { dot4Entry 7 } dot4SlotTime OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "The maximum time any station need wait for an immediate MAC-level response from another station. This value must the same in all stations on the 802.4 network." ::= { dot4Entry 8 } dot4LastTokenRotTime OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "The observed token rotation time for the last token rotation, timed from token arrival to token arrival. A value of zero indicates that the token is not rotating." ::= { dot4Entry 9 } dot4HiPriTokenHoldTime OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "The maximum duration for which a station can hold the token to transmit frames of access class 6 (if the priority option is implemented), or of any access class (if the priority option is not implemented)." ::= { dot4Entry 10 } dot4TargetRotTimeClass4 OBJECT-TYPE SYNTAX OctetTime ACCESS read-onlyTransmission Working Group [Page 9]RFC 1230 IEEE 802.4 MIB May 1991 STATUS mandatory DESCRIPTION "If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 4. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used, this object has the value 0." ::= { dot4Entry 11 } dot4TargetRotTimeClass2 OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 2. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used, this object has the value 0." ::= { dot4Entry 12 } dot4TargetRotTimeClass0 OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 0. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used,Transmission Working Group [Page 10]RFC 1230 IEEE 802.4 MIB May 1991 this object has the value 0." ::= { dot4Entry 13 } dot4TargetRotTimeRingMaint OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "A value used to limit the duration of a token rotation. If the duration of a token rotation exceeds this value, the station will not open the response window to solicit for a new successor." ::= { dot4Entry 14 } dot4RingMaintTimerInitValue OBJECT-TYPE SYNTAX OctetTime ACCESS read-only STATUS mandatory DESCRIPTION "The value to which the dot4TargetRotTimeRingMaint is set, each time the station enters the ring. A large value will cause the station to solicit successors immediately upon entry to the ring; a value of zero will cause the station to defer this solicitation for at least one token rotation." ::= { dot4Entry 15 } dot4MaxInterSolicitCount OBJECT-TYPE SYNTAX INTEGER (16..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of consecutive token rotations without soliciting for a successor. If this count expires, the station opens the response window to solicit for a successor (providing the duration of the current token rotation has not exceeded dot4TargetRotTimeRingMaint). The least significant two bits of the count are determined randomly by the station on a per-use basis." ::= { dot4Entry 16 }Transmission Working Group [Page 11]RFC 1230 IEEE 802.4 MIB May 1991 dot4MaxRetries OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries of a Request-with-Response (RWR) frame. If the RWR option is not in use, this object has the value 0." ::= { dot4Entry 17 } dot4MinPostSilencePreambLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum number of octets of preamble on the first frame transmitted by this station after a period of 'transmitted' silence." ::= { dot4Entry 18 } dot4StandardRevision OBJECT-TYPE SYNTAX INTEGER {
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -