⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1230.txt

📁 <VC++网络游戏建摸与实现>源代码
💻 TXT
📖 第 1 页 / 共 4 页
字号:
                             dot4StandardRevision                                 INTEGER                         }          dot4IfIndex  OBJECT-TYPE                     SYNTAX  INTEGER                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The value of this object identifies theTransmission Working Group                                      [Page 6]RFC 1230                     IEEE 802.4 MIB                     May 1991                             802.4 interface for which this entry                             contains management information.  The                             value of this object for a particular                             interface has the same value as the                             ifIndex object, defined in [4,6], for the                             same interface."                     ::= { dot4Entry 1 }          dot4Options OBJECT-TYPE                     SYNTAX  INTEGER                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The optional parts of the 802.4                             specification which are in use by this                             station.  The options of the 802.4                             specification are represented by the                             following values:                                   1 - Priority                                   2 - Request-With-Response                             The value of this object is given by the                             sum of the above representations for                             those options in use on this interface.                             The value zero indicates that no options                             are in use."                     ::= { dot4Entry 2 }          dot4State OBJECT-TYPE                     SYNTAX  INTEGER {                                 other(1),                                 offline(2),                                 outOfRing(3),                                 enteringRing(4),                                 inRing(5)                             }                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The current state of the 802.4                             interface.  The value of other(1) is                             used if the state is unknown                             (e.g., due to an error condition)."                     ::=   { dot4Entry 3 }          dot4Commands OBJECT-TYPE                     SYNTAX  INTEGER {                                 no-op(1),                                 enterRing(2),Transmission Working Group                                      [Page 7]RFC 1230                     IEEE 802.4 MIB                     May 1991                                 exitRing(3),                                 reset(4),                                 initialize(5)                             }                     ACCESS  read-write                     STATUS  mandatory                     DESCRIPTION                             "Setting this object causes the station                             to change the state of the interface as                             indicated by the specified value.  An                             initialize(5) command causes the                             interfaceto load its operational                             parameters from its initialization                             parameters; the value of                             dot4InitInRingDesired determines                             whether the station tries to enter the                             logical ring immediately.                                 Note that the 802.4 specification                             suggests a station remain Offline after a                             'remote Network Management' reset(4),                             until a 'local Network Management'                             initialize(5) is performed.                                 Setting this object to a value of                             no-op(1) has no effect.  When read,                             this object always has the value no-op(1)."                     ::=  { dot4Entry 4 }          dot4MacAddrLen OBJECT-TYPE                     SYNTAX  INTEGER {                                 sixteenBit(1),                                 forty-eightBit(2)                             }                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "This object indicates the size of MAC                             addresses interpreted by this station."                     ::= { dot4Entry 5 }          dot4NextStation OBJECT-TYPE                     SYNTAX  MacAddress                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The MAC address of this station's                             successor in the logical ring."                     ::= { dot4Entry 6 }Transmission Working Group                                      [Page 8]RFC 1230                     IEEE 802.4 MIB                     May 1991          dot4PreviousStation OBJECT-TYPE                     SYNTAX  MacAddress                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The source MAC address of the last token                             addressed to this station."                     ::= { dot4Entry 7 }          dot4SlotTime OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The maximum time any station need wait                             for an immediate MAC-level response from                             another station.                             This value must the same in all stations on                             the 802.4 network."                     ::= { dot4Entry 8 }          dot4LastTokenRotTime OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The observed token rotation time for the                             last token rotation, timed from token                             arrival to token arrival.  A value of                             zero indicates that the token is not                             rotating."                     ::= { dot4Entry 9 }          dot4HiPriTokenHoldTime OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The maximum duration for which a station                             can hold the token to transmit frames of                             access class 6 (if the priority option is                             implemented), or of any access class (if                             the priority option is not implemented)."                     ::= { dot4Entry 10 }          dot4TargetRotTimeClass4 OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-onlyTransmission Working Group                                      [Page 9]RFC 1230                     IEEE 802.4 MIB                     May 1991                     STATUS  mandatory                     DESCRIPTION                             "If the priority scheme is being used,                             this value specifies a limit on how long                             a station can transmit frames at access                             class 4.  The limit is measured from the                             time the station is able to start                             transmitting frames at this access class                             on one rotation, to the time it must stop                             transmitting frames at this access class                             on the next rotation.  If the priority                             scheme is not being used, this object has                             the value 0."                     ::= { dot4Entry 11 }          dot4TargetRotTimeClass2 OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "If the priority scheme is being used,                             this value specifies a limit on how long                             a station can transmit frames at access                             class 2.  The limit is measured from the                             time the station is able to start                             transmitting frames at this access                             class on one rotation, to the time it                             must stop transmitting frames at this                             access class on the next rotation.  If                             the priority scheme is not being used,                             this object has the value 0."                     ::= { dot4Entry 12 }          dot4TargetRotTimeClass0 OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "If the priority scheme is being used,                             this value specifies a limit on how long                             a station can transmit frames at access                             class 0.  The limit is measured from the                             time the station is able to start                             transmitting frames at this access                             class on one rotation, to the time it                             must stop transmitting frames at this                             access class on the next rotation.  If                             the priority scheme is not being used,Transmission Working Group                                     [Page 10]RFC 1230                     IEEE 802.4 MIB                     May 1991                             this object has the value 0."                     ::= { dot4Entry 13 }          dot4TargetRotTimeRingMaint OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "A value used to limit the duration of a                             token rotation.  If the duration of a                             token rotation exceeds this value, the                             station will not open the response window                             to solicit for a new successor."                     ::= { dot4Entry 14 }          dot4RingMaintTimerInitValue OBJECT-TYPE                     SYNTAX  OctetTime                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The value to which the                             dot4TargetRotTimeRingMaint is set, each                             time the station enters the ring.                             A large value will cause the station to                             solicit successors immediately upon entry                             to the ring; a value of zero will cause                             the station to defer this solicitation                             for at least one token rotation."                     ::= { dot4Entry 15 }          dot4MaxInterSolicitCount OBJECT-TYPE                     SYNTAX  INTEGER (16..255)                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The maximum number of consecutive token                             rotations without soliciting for a                             successor.  If this count expires, the                             station opens the response window to                             solicit for a successor (providing the                             duration of the current token rotation                             has not exceeded                             dot4TargetRotTimeRingMaint).  The least                             significant two bits of the count are                             determined randomly by the station on a                             per-use basis."                     ::= { dot4Entry 16 }Transmission Working Group                                     [Page 11]RFC 1230                     IEEE 802.4 MIB                     May 1991          dot4MaxRetries OBJECT-TYPE                     SYNTAX  INTEGER (0..7)                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The maximum number of retries of a                             Request-with-Response (RWR) frame.  If                             the RWR option is not in use, this object                             has the value 0."                     ::= { dot4Entry 17 }          dot4MinPostSilencePreambLen OBJECT-TYPE                     SYNTAX  INTEGER                     ACCESS  read-only                     STATUS  mandatory                     DESCRIPTION                             "The minimum number of octets of preamble                             on the first frame transmitted by this                             station after a period of 'transmitted'                             silence."                     ::= { dot4Entry 18 }          dot4StandardRevision OBJECT-TYPE                     SYNTAX  INTEGER {

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -