📄 hplm16c62padc.nc

📁 tinyos-2.x.rar
💻 NC
字号:
/// $Id: HplM16c62pAdc.nc,v 1.1 2009/09/07 14:12:25 r-studio Exp $

/*
 * Copyright (c) 2004-2005 Crossbow Technology, Inc.  All rights reserved.
 *
 * Permission to use, copy, modify, and distribute this software and its
 * documentation for any purpose, without fee, and without written agreement is
 * hereby granted, provided that the above copyright notice, the following
 * two paragraphs and the author appear in all copies of this software.
 * 
 * IN NO EVENT SHALL CROSSBOW TECHNOLOGY OR ANY OF ITS LICENSORS BE LIABLE TO 
 * ANY PARTY FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL 
 * DAMAGES ARISING OUT OF THE USE OF THIS SOFTWARE AND ITS DOCUMENTATION, EVEN
 * IF CROSSBOW OR ITS LICENSOR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH 
 * DAMAGE. 
 *
 * CROSSBOW TECHNOLOGY AND ITS LICENSORS SPECIFICALLY DISCLAIM ALL WARRANTIES,
 * INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY 
 * AND FITNESS FOR A PARTICULAR PURPOSE. THE SOFTWARE PROVIDED HEREUNDER IS 
 * ON AN "AS IS" BASIS, AND NEITHER CROSSBOW NOR ANY LICENSOR HAS ANY 
 * OBLIGATION TO PROVIDE MAINTENANCE, SUPPORT, UPDATES, ENHANCEMENTS, OR 
 * MODIFICATIONS.
 */

#include "M16c62pAdc.h"

/**
 * HPL interface to the M16c62p A/D conversion subsystem. 
 * <p>
 * conversion when the ADC and ADC interrupt are enabled.
 *
 * @author Martin Turon <mturon@xbow.com>
 * @author Hu Siquan <husq@xbow.com>
 * @author David Gay
 */

interface HplM16c62pAdc {
  /**
   * Read the ADCON0 (ADC control register 0)
   * @return Current ADCON0 value
   */
  async command M16c62pADCON0_t getADCON0();
  /**
   * Set the ADCON0 (ADC control register 0)
   * @param adcon0 New ADCON0 value
   */
  async command void setADCON0(M16c62pADCON0_t adcon0);
/////////////////////////////////////////////////////////////////////////////////
  /**
   * Read the ADCON1 (ADC control) register
   * @return Current ADCON1 value
   */
  async command M16c62pADCON1_t getADCON1();
  /**
   * Set the ADCON1 (ADC control) register
   * @param adcon1 New ADCON1 value
   */
  async command void setADCON1(M16c62pADCON1_t adcon1);
//////////////////////////////////////////////////////////////////////////////////   
  /**
   * Read the ADCON2 (ADC control) register
   * @return Current ADCON2 value
   */
  async command M16c62pADCON2_t getADCON2();
  /**
   * Set the ADCON2 (ADC control) register
   * @param adcon2 New ADCON2 value
   */
  async command void setADCON2(M16c62pADCON2_t adcon2);
/////////////////////////////////////////////////////////////////////////////////
  /**
   * Read the latest A/D conversion result
   * @return A/D value
   */
  async command uint16_t getValue();

  /// A/D control utilities. All of these clear any pending A/D interrupt.

  /**
   * Enable ADC sampling
   */
  async command void enableAdc();
  /**
   * Disable ADC sampling
   */
  async command void disableAdc();

  /**
   * Enable ADC interrupt
   */
  async command void enableInterruption();
  /**
   * Disable ADC interrupt
   */
  async command void disableInterruption();
  /**
   * Clear the ADC interrupt flag
   */
  async command void resetInterrupt();

  /**
   * Start ADC conversion. If ADC interrupts are enabled, the dataReady event
   * will be signaled once (in non-continuous mode) or repeatedly (in
   * continuous mode).
   */
  async command void startConversion();
  /**
   * Enable continuous sampling
   */
  async command void setContinuous();
  /**
   * Disable continuous sampling
   */
  async command void setSingle();

  /* A/D status checks */

  /**
   * Is ADC enabled?
   * @return TRUE if the ADC is enabled, FALSE otherwise
   */
  async command bool isEnabled();
  /**
   * Is A/D conversion in progress?
   * @return TRUE if the A/D conversion is in progress, FALSE otherwise
   */
  async command bool isStarted();
  /**
   * Is A/D conversion complete? Note that this flag is automatically
   * cleared when an A/D interrupt occurs.
   * @return TRUE if the A/D conversion is complete, FALSE otherwise
   */
  async command bool isComplete();
  
  
  /**
   * Set ADC precision selection bits
   * @param scale New ADC prescision. Must be one of the M16c62p_ADC_PRECISION_xxx
   *   values from M16c62pAdc.h
   */
  async command void setPrecision(uint8_t precision);
  
  /**
   * Set ADC prescaler selection bits
   * @param scale New ADC prescaler. Must be one of the M16c62p_ADC_PRESCALE_xxx
   *   values from M16c62pAdc.h
   */
  async command void setPrescaler(uint8_t scale);

  /**
   * Cancel A/D conversion and any pending A/D interrupt. Also disables the
   * ADC interruption (otherwise a sample might start at the next sleep
   * instruction). This command can assume that the A/D converter is enabled. 
   * @return TRUE if an A/D conversion was in progress or an A/D interrupt
   *   was pending, FALSE otherwise. In single conversion mode, a return
   *   of TRUE implies that the dataReady event will not be signaled.
   */
  async command bool cancel();

  /**
   * A/D interrupt occured
   * @param data Latest A/D conversion result
   */
  async event void dataReady(uint16_t data);     
}