📄 rfc2513.txt
字号:
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds between the periodic collections of
accounting data when the value of the corresponding instance
of acctngFileCollectMode includes 'periodically'. Some
agents may impose restrictions on the range of this
interval. This value may be modified at any time."
DEFVAL { 3600 }
::= { acctngFileEntry 11 }
acctngFileMinAge OBJECT-TYPE
SYNTAX Integer32 (60..86400)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum age of a connection, as used to determine the
set of connections for which data is to be collected at the
periodic intervals and/or when acctngFileCommand is set to
'collectNow'. The age of a connection is the elapsed time
since it was last installed.
When the periodic interval expires for a file or when
acctngFileCommand is set to 'collectNow', accounting data is
collected and stored in the file for each connection having
a type matching acctngSelectionType and whose age at that
time is greater than the value of acctngFileMinAge
McCloghrie, et. al. Standards Track [Page 18]
RFC 2513 Connection-Oriented Accounting MIB February 1999
associated with the file. This value may be modified at any
time."
DEFVAL { 3600 }
::= { acctngFileEntry 12 }
acctngFileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row.
This object can not be set to 'active' until a value has
been assigned to the corresponding instance of
acctngFileName. Collection of data into the file does not
begin until this object has the value 'active' and one or
more (active) instances of acctngSelectionFile refer to it.
If this value is modified after a collection has begun,
collection into this file terminates and a new (or new
version of the) file is immediately made ready for future
collection (as if acctngFileCommand had been set to
'swapToNewFile'), but collection into the new (or new
version of the) file does not begin until the value is
subsequently set back to active."
::= { acctngFileEntry 13 }
-- Overall Control
acctngAdminStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control object to indicate the administratively desired
state of the collection of accounting records across all
interfaces.
Modifying the value of acctngAdminStatus to 'disabled' does
not remove or change the current configuration as
represented by the active rows in the acctngSelectionTable,
acctngFileTable and acctngInterfaceTable tables."
::= { acctngInterfaceControl 1 }
acctngOperStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
McCloghrie, et. al. Standards Track [Page 19]
RFC 2513 Connection-Oriented Accounting MIB February 1999
"A status object to indicate the operational state of the
collection of accounting records across all interfaces.
When the value of acctngAdminStatus is modified to be
'enabled', the value of this object will change to 'enabled'
providing it is possible to begin collecting accounting
records.
When the value of acctngAdminStatus is modified to be
'disabled', the value of this object will change to
'disabled' as soon as the collection of accounting records
has terminated."
::= { acctngInterfaceControl 2 }
acctngProtection OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control object to protect against duplication of control
commands. Over some transport/network protocols, it is
possible for SNMP messages to get duplicated. Such
duplication, if it occurred at just the wrong time could
cause serious disruption to the collection and retrieval of
accounting data, e.g., if a SNMP message setting
acctngFileCommand to 'swapToNewFile' were to be duplicated,
a whole file of accounting data could be lost.
To protect against such duplication, a management
application should retrieve the value of this object, and
include in the Set operation needing protection, a variable
binding which sets this object to the retrieved value."
::= { acctngInterfaceControl 3 }
acctngAgentMode OBJECT-TYPE
SYNTAX INTEGER { swapOnCommand(1), swapOnFull(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of the behaviour mode of the agent when a
file becomes full:
'swapOnCommand' - the agent does not automatically swap
to a new file; rather, it discards newly collected
data until a management application subsequently
instructs it to swap to a new file.
'swapOnFull' - the agent terminates collection into the
McCloghrie, et. al. Standards Track [Page 20]
RFC 2513 Connection-Oriented Accounting MIB February 1999
current file as and when that file becomes full."
::= { acctngInterfaceControl 4 }
-- Per-interface control table
acctngInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcctngInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table controlling the collection of accounting data on
specific interfaces of the switch."
::= { acctngInterfaceControl 5 }
acctngInterfaceEntry OBJECT-TYPE
SYNTAX AcctngInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry which controls whether accounting data is to be
collected on an interface. The types of interfaces which
are represented in this table is implementation-specific."
INDEX { ifIndex }
::= { acctngInterfaceTable 1 }
AcctngInterfaceEntry ::=
SEQUENCE {
acctngInterfaceEnable TruthValue
}
acctngInterfaceEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the collection of accounting data is
enabled on this interface."
::= { acctngInterfaceEntry 1 }
-- Objects for controlling the use of Notifications
acctngControlTrapThreshold OBJECT-TYPE
SYNTAX INTEGER (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A percentage of the maximum file size at which a 'nearly-
McCloghrie, et. al. Standards Track [Page 21]
RFC 2513 Connection-Oriented Accounting MIB February 1999
full' trap is generated. The value of 0 indicates that no
'nearly-full' trap is to be generated."
::= { acctngTrapControl 1 }
acctngControlTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An indication of whether the acctngFileNearlyFull and
acctngFileFull traps are enabled."
::= { acctngTrapControl 2 }
-- notifications
acctngNotifications OBJECT IDENTIFIER ::= { accountingControlMIB 2 }
acctngNotifyPrefix OBJECT IDENTIFIER ::= { acctngNotifications 0 }
acctngFileNearlyFull NOTIFICATION-TYPE
OBJECTS { acctngFileName,
acctngFileMaximumSize,
acctngControlTrapThreshold,
acctngFileNameSuffix }
STATUS current
DESCRIPTION
"An indication that the size of the file into which
accounting information is currently being collected has
exceeded the threshold percentage of its maximum file size.
This notification is generated only at the time of the
transition from not-exceeding to exceeding."
::= { acctngNotifyPrefix 1 }
acctngFileFull NOTIFICATION-TYPE
OBJECTS { acctngFileName,
acctngFileMaximumSize,
acctngFileNameSuffix }
STATUS current
DESCRIPTION
"An indication that the size of the file into which
accounting information is currently being collected has
transistioned to its maximum file size. This notification
is generated (for all values of acctngAgentMode) at the time
of the transition from not-full to full. If acctngAgentMode
has the value 'swapOnCommand', it is also generated
periodically thereafter until such time as collection of
McCloghrie, et. al. Standards Track [Page 22]
RFC 2513 Connection-Oriented Accounting MIB February 1999
data is no longer inhibited by the file full condition."
::= { acctngNotifyPrefix 2 }
-- conformance information
acctngConformance OBJECT IDENTIFIER ::= { accountingControlMIB 3 }
acctngGroups OBJECT IDENTIFIER ::= { acctngConformance 1 }
acctngCompliances OBJECT IDENTIFIER ::= { acctngConformance 2 }
acctngCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for switches which implement the
Accounting Control MIB."
MODULE -- this module
MANDATORY-GROUPS { acctngBasicGroup,
acctngNotificationsGroup }
OBJECT acctngSelectionType
SYNTAX BITS { svcIncoming(0), svcOutgoing(1) }
DESCRIPTION "The minimal requirement is collection for SVCs."
OBJECT acctngSelectionRowStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT acctngFileName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT acctngFileCommand
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT acctngFileFormat
SYNTAX INTEGER { ber(2) }
MIN-ACCESS read-only
DESCRIPTION "Only the standard format is required, and write
access is not required."
OBJECT acctngFileMaximumSize
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT acctngFileCollectMode
SYNTAX BITS { onRelease(0) }
McCloghrie, et. al. Standards Track [Page 23]
RFC 2513 Connection-Oriented Accounting MIB February 1999
MIN-ACCESS read-only
DESCRIPTION "The minimal requirement is for collection on
connection release."
OBJECT acctngFileInterval
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT acctngFileCollectFailedAttempts
MIN-ACCESS read-only
⌨️ 快捷键说明