rfc1230.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 1,291 行 · 第 1/4 页
TXT
1,291 行
rev2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Revision number of the 802.4 standard
implemented by this station."
::= { dot4Entry 19 }
-- 802.4 Initialization Table
-- This table contains the parameter information used by an
-- 802.4 interface as the values to be assigned to its
-- operational parameters upon initialization. It is
-- mandatory that systems having 802.4 interfaces implement
-- this table.
dot4InitTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot4InitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Bus
Transmission Working Group [Page 12]
RFC 1230 IEEE 802.4 MIB May 1991
initialization parameters, one entry per
802.4 interface."
::= { dot4 2 }
dot4InitEntry OBJECT-TYPE
SYNTAX Dot4InitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Bus initialization
parameters for an 802.4 interface."
INDEX { dot4InitIfIndex }
::= { dot4InitTable 1 }
Dot4InitEntry ::= SEQUENCE {
dot4InitIfIndex
INTEGER,
dot4InitSlotTime
OctetTime,
dot4InitMaxInterSolicitCount
INTEGER (16..255),
dot4InitMaxRetries
INTEGER (0..7),
dot4InitHiPriTokenHoldTime
OctetTime,
dot4InitTargetRotTimeClass4
OctetTime,
dot4InitTargetRotTimeClass2
OctetTime,
dot4InitTargetRotTimeClass0
OctetTime,
dot4InitTargetRotTimeRingMaint
OctetTime,
dot4InitRingMaintTimerInitValue
OctetTime,
dot4InitMinPostSilencePreambLen
INTEGER,
dot4InitInRingDesired
INTEGER
}
dot4InitIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.4 interface for which this entry
Transmission Working Group [Page 13]
RFC 1230 IEEE 802.4 MIB May 1991
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6], for
the same interface."
::= { dot4InitEntry 1 }
dot4InitSlotTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4SlotTime when the station is
initialized."
::= { dot4InitEntry 2 }
dot4InitMaxInterSolicitCount OBJECT-TYPE
SYNTAX INTEGER (16..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MaxInterSolicitCount when the station
is initialized."
::= { dot4InitEntry 3 }
dot4InitMaxRetries OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MaxRetries when the station is
initialized."
::= { dot4InitEntry 4 }
dot4InitHiPriTokenHoldTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4HiPriTokenHoldTime when the station
is initialized."
::= { dot4InitEntry 5 }
Transmission Working Group [Page 14]
RFC 1230 IEEE 802.4 MIB May 1991
dot4InitTargetRotTimeClass4 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass4 when the station
is initialized."
::= { dot4InitEntry 6 }
dot4InitTargetRotTimeClass2 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass2 when the station
is initialized."
::= { dot4InitEntry 7 }
dot4InitTargetRotTimeClass0 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass0 when the station
is initialized."
::= { dot4InitEntry 8 }
dot4InitTargetRotTimeRingMaint OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeRingMaint when the station
is initialized."
::= { dot4InitEntry 9 }
dot4InitRingMaintTimerInitValue OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4RingMaintTimerInitValue when the
station is initialized."
Transmission Working Group [Page 15]
RFC 1230 IEEE 802.4 MIB May 1991
::= { dot4InitEntry 10 }
dot4InitMinPostSilencePreambLen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MinPostSilencePreambLen when the
station is initialized."
::= { dot4InitEntry 11 }
dot4InitInRingDesired OBJECT-TYPE
SYNTAX INTEGER {
inRing(1),
outOfRing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether the
station will attempt to enter the logical
ring immediately after initialization."
::= { dot4InitEntry 12 }
-- 802.4 Statistics Table
-- This table contains Token Bus statistics, one entry per
-- 802.4 interface. It is mandatory that systems having
-- 802.4 interfaces implement this table.
dot4StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot4StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing Token Bus statistics.
All the statistics are defined using the
syntax Counter as 32 bit wrap around
counters. Thus, if an interface's
hardware chip set maintains these
statistics in 16-bit counters, then the
agent must read the hardware's counters
frequently enough to prevent loss of
significance, in order to maintain
a 32-bit counter in software."
::= { dot4 3 }
Transmission Working Group [Page 16]
RFC 1230 IEEE 802.4 MIB May 1991
dot4StatsEntry OBJECT-TYPE
SYNTAX Dot4StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing the 802.4 statistics
for a particular interface."
INDEX { dot4StatsIfIndex }
::= { dot4StatsTable 1 }
Dot4StatsEntry ::= SEQUENCE {
dot4StatsIfIndex
INTEGER,
dot4StatsTokenPasses
Counter,
dot4StatsTokenHeards
Counter,
dot4StatsNoSuccessors
Counter,
dot4StatsWhoFollows
Counter,
dot4StatsTokenPassFails
Counter,
dot4StatsNonSilences
Counter,
dot4StatsFcsErrors
Counter,
dot4StatsEbitErrors
Counter,
dot4StatsFrameFrags
Counter,
dot4StatsFrameTooLongs
Counter,
dot4StatsOverRuns
Counter,
dot4StatsDupAddresses
Counter
}
dot4StatsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.4 interface for which this entry
contains management information. The
value of this object for a particular
Transmission Working Group [Page 17]
RFC 1230 IEEE 802.4 MIB May 1991
interface has the same value as the
ifIndex object, defined in [4,6], for the
same interface."
::= { dot4StatsEntry 1 }
dot4StatsTokenPasses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times this station has
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?