rfc1660.txt

来自「RFC 的详细文档!」· 文本 代码 · 共 564 行 · 第 1/2 页

TXT
564
字号

RFC 1660               Parallel-printer-like MIB               July 1994


   -- Parallel-printer-like Input Signal Table

   paraInSigTable OBJECT-TYPE
       SYNTAX SEQUENCE OF ParaInSigEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "A list of port input control signal entries."
       ::= { para 3 }

   paraInSigEntry OBJECT-TYPE
       SYNTAX ParaInSigEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Input control signal status for a hardware port."
       INDEX { paraInSigPortIndex, paraInSigName }
       ::= { paraInSigTable 1 }

   ParaInSigEntry ::=
       SEQUENCE {
           paraInSigPortIndex
               InterfaceIndex,
           paraInSigName
               INTEGER,
           paraInSigState
               INTEGER,
           paraInSigChanges
               Counter32
       }

   paraInSigPortIndex OBJECT-TYPE
       SYNTAX InterfaceIndex
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The value of paraPortIndex for the port to which
           this entry belongs."
       ::= { paraInSigEntry 1 }

   paraInSigName OBJECT-TYPE
       SYNTAX INTEGER { power(1), online(2), busy(3),
                        paperout(4), fault(5) }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Identification of a hardware signal."
       ::= { paraInSigEntry 2 }



Stewart                                                         [Page 6]

RFC 1660               Parallel-printer-like MIB               July 1994


   paraInSigState OBJECT-TYPE
       SYNTAX INTEGER { none(1), on(2), off(3) }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The current signal state."
       ::= { paraInSigEntry 3 }

   paraInSigChanges OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The number of times the signal has changed from
           'on' to 'off' or from 'off' to 'on'."
       ::= { paraInSigEntry 4 }


   -- Output Signal Table

   paraOutSigTable OBJECT-TYPE
       SYNTAX SEQUENCE OF ParaOutSigEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "A list of port output control signal entries."
       ::= { para 4 }

   paraOutSigEntry OBJECT-TYPE
       SYNTAX ParaOutSigEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Output control signal status for a hardware port."
       INDEX { paraOutSigPortIndex, paraOutSigName }
       ::= { paraOutSigTable 1 }

   ParaOutSigEntry ::=
       SEQUENCE {
           paraOutSigPortIndex
               InterfaceIndex,
           paraOutSigName
               INTEGER,
           paraOutSigState
               INTEGER,
           paraOutSigChanges
               Counter32
       }



Stewart                                                         [Page 7]

RFC 1660               Parallel-printer-like MIB               July 1994


   paraOutSigPortIndex OBJECT-TYPE
       SYNTAX InterfaceIndex
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The value of paraPortIndex for the port to which
           this entry belongs."
       ::= { paraOutSigEntry 1 }

   paraOutSigName OBJECT-TYPE
       SYNTAX INTEGER { power(1), online(2), busy(3),
                        paperout(4), fault(5) }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Identification of a hardware signal."
       ::= { paraOutSigEntry 2 }

   paraOutSigState OBJECT-TYPE
       SYNTAX INTEGER { none(1), on(2), off(3) }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The current signal state."
       ::= { paraOutSigEntry 3 }

   paraOutSigChanges OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The number of times the signal has changed from
           'on' to 'off' or from 'off' to 'on'."
       ::= { paraOutSigEntry 4 }


   -- conformance information

   paraConformance OBJECT IDENTIFIER ::= { para 5 }

   paraGroups      OBJECT IDENTIFIER ::= { paraConformance 1 }
   paraCompliances OBJECT IDENTIFIER ::= { paraConformance 2 }









Stewart                                                         [Page 8]

RFC 1660               Parallel-printer-like MIB               July 1994


   -- compliance statements

   paraCompliance MODULE-COMPLIANCE
       STATUS  current
       DESCRIPTION
               "The compliance statement for SNMPv2 entities
               which have Parallel-printer-like hardware
               interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { paraGroup }
       ::= { paraCompliances 1 }


   -- units of conformance

   paraGroup    OBJECT-GROUP
       OBJECTS { paraNumber, paraPortIndex, paraPortType,
                 paraPortInSigNumber, paraPortOutSigNumber,
                 paraInSigPortIndex, paraInSigName,
                 paraInSigState, paraInSigChanges,
                 paraOutSigPortIndex, paraOutSigName,
                 paraOutSigState, paraOutSigChanges }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
                applicable to all Parallel-printer-like interfaces."
       ::= { paraGroups 1 }

   END

5.  Acknowledgements

   This memo was produced by the IETF Character MIB Working Group.

6.  References

   [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure
       of Management Information for version 2 of the Simple Network
       Management Protocol (SNMPv2)", RFC 1442, SNMP Research,Inc.,
       Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon
       University, April 1993.

   [2] McCloghrie, K., and M. Rose, Editors, "Management Information
       Base for Network Management of TCP/IP-based internets: MIB-II",
       STD 17, RFC 1213, Hughes LAN Systems, Performance Systems
       International, March 1991.




Stewart                                                         [Page 9]

RFC 1660               Parallel-printer-like MIB               July 1994


   [3] Galvin, J., and K. McCloghrie, "Administrative Model for version
       2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,
       Trusted Information Systems, Hughes LAN Systems, April 1993.

   [4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol
       Operations for version 2 of the Simple Network Management
       Protocol (SNMPv2)", RFC 1448, SNMP Research,Inc., Hughes LAN
       Systems, Dover Beach Consulting, Inc., Carnegie Mellon
       University, April 1993.

   [5] McCloghrie, K., and F. Kastenholz, "Evolution of the Interfaces
       Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software,
       January 1994.

   [6] Stewart, B., "Definitions of Managed Objects for Character Stream
       Devices using SMIv2", RFC 1658, Xyplex, Inc., July 1994.

   [7] Stewart, B., "Definitions of Managed Objects for RS-232-like
       Devices using SMIv2", RFC 1659, Xyplex, Inc., July 1994.

7.  Security Considerations

   Security issues are not discussed in this memo.

8.  Author's Address

   Bob Stewart
   Xyplex, Inc.
   295 Foster Street
   Littleton, MA 01460

   Phone: 508-952-4816
   Fax: 508-952-4887
   EMail: rlstewart@eng.xyplex.com

















Stewart                                                        [Page 10]
