DESCRIPTION
"Class for this flow. Determined by the rules, set by a
PushRule action when this flow was entered in the table."
::= { flowDataEntry 41 }
--
-- The Activity Column Table
--
flowColumnActivityTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into the Flow Table. Allows a meter reader to retrieve
a list containing the flow table indeces of flows which were
last active at or after a given time, together with the values
of a specified attribute for each such flow."
::= { flowData 2 }
flowColumnActivityEntry OBJECT-TYPE
SYNTAX FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Column Activity Entry for a particular attribute,
activity time and flow."
INDEX { flowColumnActivityAttribute, flowColumnActivityTime,
flowColumnActivityIndex }
::= { flowColumnActivityTable 1 }
FlowColumnActivityEntry ::= SEQUENCE {
Brownlee Experimental [Page 29]
RFC 2064 Meter MIB January 1997
flowColumnActivityAttribute FlowAttributeNumber,
flowColumnActivityTime TimeFilter,
flowColumnActivityIndex Integer32,
flowColumnActivityData OCTET STRING
}
flowColumnActivityAttribute OBJECT-TYPE
SYNTAX FlowAttributeNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the attribute for which values are required from
active flows."
::= { flowColumnActivityEntry 1 }
flowColumnActivityTime OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is a copy of flowDataLastActiveTime in the
flow data record identified by the flowColumnActivityIndex
value of this flowColumnActivityTable entry."
::= { flowColumnActivityEntry 2 }
flowColumnActivityIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of a flow table entry which was active at or after
a specified flowColumnActivityTime."
::= { flowColumnActivityEntry 3 }
flowColumnActivityData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3..1000))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Collection of attribute data for flows active after
flowColumnActivityTime. Within the OCTET STRING is a
sequence of { flow index, attribute value } pairs, one for
each active flow. The end of the sequence is marked by a
flow index value of 0, indicating that there are no more
rows in this column.
The format of objects inside flowColumnFlowData is as follows.
All numbers are unsigned. Numbers and strings appear with
Brownlee Experimental [Page 30]
RFC 2064 Meter MIB January 1997
their high-order bytes leading. Numbers are fixed size, as
specified by their SYNTAX in the flow table (above), i.e. one
octet for flowAddressType and small constants, and four octets
for Counter and Timeticks. Strings are variable-length, with
the length given in a single leading octet.
The following is an attempt at an ASN.1 definition of
flowColumnActivityData:
flowColumnActivityData ::= SEQUENCE flowRowItemEntry
flowRowItemEntry ::= SEQUENCE {
flowRowNumber INTEGER (1..65535),
-- 0 indicates the end of this column
flowDataValue flowDataType -- Choice depends on attribute
}
flowDataType ::= CHOICE {
flowByteValue INTEGER (1..255),
flowShortValue INTEGER (1..65535),
flowLongValue Integer32,
flowStringValue OCTET STRING -- Length (n) in first byte,
-- n+1 bytes total length, trailing zeroes truncated
}"
::= { flowColumnActivityEntry 4 }
--
-- The Rule Table
--
-- This is an array of rule tables; the one in use is selected by
-- CurrentRuleSet. To change the rule set the manager chooses a set
-- number which is not in use, downloads the new rule set there, then
-- writes the new set number into CurrentRuleSet. Rule set 1 is the
-- default rule set, used by the meter on start-up. Several rule sets
-- can be held in a meter so that the manager can change the rules
-- easily, for example with time of day. Note that a manager may
-- not change the default rule set, nor the rules in its current rule
-- set! See the 'Traffic Flow Measurement: Architecture' document [9]
-- for details of rules and how they are used.
flowRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains all the rule sets which may be used by the meter."
::= { flowRules 1 }
Brownlee Experimental [Page 31]
RFC 2064 Meter MIB January 1997
flowRuleEntry OBJECT-TYPE
SYNTAX FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The rule record itself."
INDEX { flowRuleSet, flowRuleIndex }
::= { flowRuleTable 1 }
FlowRuleEntry ::= SEQUENCE {
flowRuleSet INTEGER,
flowRuleIndex INTEGER,
flowRuleSelector RuleAttributeNumber,
flowRuleMask RuleAddress,
flowRuleMatchedValue RuleAddress,
flowRuleAction ActionNumber,
flowRuleParameter Integer32
}
flowRuleSet OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Selects a rule set from the array of rule sets."
::= { flowRuleEntry 1 }
flowRuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index into the Rule table. N.B: These values will
often be consecutive, given the fall-through semantics of
processing the table."
::= { flowRuleEntry 2 }
flowRuleSelector OBJECT-TYPE
SYNTAX RuleAttributeNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the attribute to be matched.
null(0) is a special case; null rules always succeed.
v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
variables, each of which can hold the name (i.e. selector
Brownlee Experimental [Page 32]
RFC 2064 Meter MIB January 1997
value) of an address attribute. When one of these is used
as a selector, its value specifies the attribute to be
tested. Variable values are set by an Assign action."
::= { flowRuleEntry 3 }
flowRuleMask OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The initial mask used to compute the desired value. If the
mask is zero the rule's test will always succeed."
::= { flowRuleEntry 4 }
flowRuleMatchedValue OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The resulting value to be matched for equality.
Specifically, if the attribute chosen by the flowRuleSelector
logically ANDed with the mask specified by the flowRuleMask
equals the value specified in the flowRuleMatchedValue, then
continue processing the table entry based on the action
specified by the flowRuleAction entry. Otherwise, proceed to
the next entry in the rule table."
::= { flowRuleEntry 5 }
flowRuleAction OBJECT-TYPE
SYNTAX ActionNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The action to be taken if this rule's test succeeds, or if
the meter's 'test' flag is off. Actions are opcodes for the
meter's Packet Matching Engine; details are given in the
'Traffic Flow Measurement: Architecture' document [9]."
::= { flowRuleEntry 6 }
flowRuleParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A parameter value providing extra information for the
rule's action."
::= { flowRuleEntry 7 }
Brownlee Experimental [Page 33]
RFC 2064 Meter MIB January 1997
--
-- Traffic Flow Meter conformance statement
--
flowMIBCompliances
OBJECT IDENTIFIER ::= { flowMIBConformance 1 }
flowMIBGroups
OBJECT IDENTIFIER ::= { flowMIBConformance 2 }
flowControlGroup OBJECT-GROUP
OBJECTS {
flowRuleInfoSize, flowRuleInfoOwner,
flowRuleInfoTimeStamp, flowRuleInfoStatus,
flowInterfaceRate,
flowInterfaceLostPackets,
flowReaderTimeout, flowReaderOwner,
flowReaderLastTime, flowReaderPreviousTime,
flowReaderStatus,
flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
flowManagerHighWaterMark,
flowManagerOwner, flowManagerTimeStamp,
flowManagerStatus,
flowFloodMark,
flowInactivityTimeout,
flowActiveFlows,
flowMaxFlows }
STATUS current
DESCRIPTION
"The control group defines objects which are used to control
an accounting meter."
::= {flowMIBGroups 1 }
flowDataTableGroup OBJECT-GROUP
OBJECTS {
flowDataIndex,
flowDataStatus,
flowDataSourceInterface,
flowDataSourceAdjacentType,
flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask,
flowDataSourcePeerType,
flowDataSourcePeerAddress, flowDataSourcePeerMask,
flowDataSourceTransType,
flowDataSourceTransAddress, flowDataSourceTransMask,
flowDataDestInterface,
flowDataDestAdjacentType,
flowDataDestAdjacentAddress, flowDataDestAdjacentMask,
flowDataDestPeerType,
Brownlee Experimental [Page 34]
RFC 2064 Meter MIB January 1997
flowDataDestPeerAddress, flowDataDestPeerMask,
flowDataDestTransType,
flowDataDestTransAddress, flowDataDestTransMask,
flowDataRuleSet,
flowDataToOctets, flowDataToPDUs,
flowDataFromOctets, flowDataFromPDUs,
flowDataFirstTime, flowDataLastActiveTime,
flowDataSourceClass, flowDataDestClass, flowDataClass,
flowDataSourceKind, flowDataDestKind, flowDataKind
}
STATUS current
DESCRIPTION
"The flow table group defines objects which provide the
structure for the rule table, including the creation time
and activity time indexes into it. In addition it defines
objects which provide a base set of flow attributes for the
adjacent, peer and transport layers, together with a flow's
counters and times. Finally it defines a flow's class and
kind attributes, which are set by rule actions."
::= {flowMIBGroups 2 }
flowDataScaleGroup OBJECT-GROUP
OBJECTS {
flowManagerCounterWrap,
flowDataPDUScale, flowDataOctetScale
}
STATUS current
DESCRIPTION
"The flow scale group defines objects which specify scale
factors for counters."
::= {flowMIBGroups 3 }
flowDataSubscriberGroup OBJECT-GROUP
OBJECTS {
flowDataSourceSubscriberID, flowDataDestSubscriberID,
flowDataSessionID
}
STATUS current
DESCRIPTION
"The flow subscriber group defines objects which may be used
to identify the end point(s) of a flow."
::= {flowMIBGroups 4 }
flowDataColumnTableGroup OBJECT-GROUP
OBJECTS {
flowColumnActivityAttribute,
flowColumnActivityTime,
flowColumnActivityIndex,
Brownlee Experimental [Page 35]
RFC 2064 Meter MIB January 1997
flowColumnActivityData
}
STATUS current
DESCRIPTION
"The flow column table group defines objects which can be used
to collect part of a column of attribute values from the flow
table."
::= {flowMIBGroups 5 }
flowRuleTableGroup OBJECT-GROUP
OBJECTS {
flowRuleSelector,
flowRuleMask, flowRuleMatchedValue,
flowRuleAction, flowRuleParameter
}
STATUS current
DESCRIPTION
"The rule table group