rfc2064.txt

来自「RFC 的详细文档!」· 文本 代码 · 共 1,984 行 · 第 1/5 页

TXT
1,984 行
字号
    STATUS  current
    DESCRIPTION
        "Class for this flow.  Determined by the rules, set by a
        PushRule action when this flow was entered in the table."
    ::= { flowDataEntry 41 }


--
-- The Activity Column Table
--

flowColumnActivityTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF FlowColumnActivityEntry
    MAX-ACCESS  not-accessible
    STATUS   current
    DESCRIPTION
        "Index into the Flow Table.  Allows a meter reader to retrieve
        a list containing the flow table indeces of flows which were
        last active at or after a given time, together with the values
        of a specified attribute for each such flow."
    ::= { flowData 2 }

flowColumnActivityEntry OBJECT-TYPE
    SYNTAX  FlowColumnActivityEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The Column Activity Entry for a particular attribute,
        activity time and flow."
    INDEX { flowColumnActivityAttribute, flowColumnActivityTime,
            flowColumnActivityIndex }
    ::= { flowColumnActivityTable 1 }

FlowColumnActivityEntry ::= SEQUENCE {



Brownlee                      Experimental                     [Page 29]

RFC 2064                       Meter MIB                    January 1997


    flowColumnActivityAttribute   FlowAttributeNumber,
    flowColumnActivityTime        TimeFilter,
    flowColumnActivityIndex       Integer32,
    flowColumnActivityData        OCTET STRING
    }

flowColumnActivityAttribute OBJECT-TYPE
    SYNTAX  FlowAttributeNumber
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Specifies the attribute for which values are required from
        active flows."
    ::= { flowColumnActivityEntry 1 }

flowColumnActivityTime OBJECT-TYPE
    SYNTAX  TimeFilter
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "This variable is a copy of flowDataLastActiveTime in the
        flow data record identified by the flowColumnActivityIndex
        value of this flowColumnActivityTable entry."
    ::= { flowColumnActivityEntry 2 }

flowColumnActivityIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Index of a flow table entry which was active at or after
        a specified flowColumnActivityTime."
    ::= { flowColumnActivityEntry 3 }

flowColumnActivityData OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (3..1000))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "Collection of attribute data for flows active after
        flowColumnActivityTime.  Within the OCTET STRING is a
        sequence of { flow index, attribute value } pairs, one for
        each active flow.  The end of the sequence is marked by a
        flow index value of 0, indicating that there are no more
        rows in this column.

        The format of objects inside flowColumnFlowData is as follows.
        All numbers are unsigned.  Numbers and strings appear with



Brownlee                      Experimental                     [Page 30]

RFC 2064                       Meter MIB                    January 1997


        their high-order bytes leading.  Numbers are fixed size, as
        specified by their SYNTAX in the flow table (above), i.e. one
        octet for flowAddressType and small constants, and four octets
        for Counter and Timeticks.  Strings are variable-length, with
        the length given in a single leading octet.

        The following is an attempt at an ASN.1 definition of
        flowColumnActivityData:

        flowColumnActivityData ::= SEQUENCE flowRowItemEntry
        flowRowItemEntry ::= SEQUENCE {
           flowRowNumber    INTEGER (1..65535),
                                 -- 0 indicates the end of this column
           flowDataValue   flowDataType -- Choice depends on attribute
           }
        flowDataType ::= CHOICE {
            flowByteValue   INTEGER (1..255),
            flowShortValue  INTEGER (1..65535),
            flowLongValue   Integer32,
            flowStringValue OCTET STRING  -- Length (n) in first byte,
                  -- n+1 bytes total length, trailing zeroes truncated
            }"
    ::= { flowColumnActivityEntry 4 }


--
-- The Rule Table
--

-- This is an array of rule tables; the one in use is selected by
-- CurrentRuleSet.  To change the rule set the manager chooses a set
-- number which is not in use, downloads the new rule set there, then
-- writes the new set number into CurrentRuleSet.  Rule set 1 is the
-- default rule set, used by the meter on start-up.  Several rule sets
-- can be held in a meter so that the manager can change the rules
-- easily, for example with time of day.  Note that a manager may
-- not change the default rule set, nor the rules in its current rule
-- set!  See the 'Traffic Flow Measurement: Architecture' document [9]
-- for details of rules and how they are used.

flowRuleTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF FlowRuleEntry
    MAX-ACCESS  not-accessible
    STATUS   current
    DESCRIPTION
        "Contains all the rule sets which may be used by the meter."
    ::= { flowRules 1 }




Brownlee                      Experimental                     [Page 31]

RFC 2064                       Meter MIB                    January 1997


flowRuleEntry OBJECT-TYPE
    SYNTAX  FlowRuleEntry
    MAX-ACCESS  not-accessible
    STATUS   current
    DESCRIPTION
        "The rule record itself."
    INDEX { flowRuleSet, flowRuleIndex }
    ::= { flowRuleTable 1 }

FlowRuleEntry ::= SEQUENCE {
    flowRuleSet                  INTEGER,
    flowRuleIndex                INTEGER,
    flowRuleSelector             RuleAttributeNumber,
    flowRuleMask                 RuleAddress,
    flowRuleMatchedValue         RuleAddress,
    flowRuleAction               ActionNumber,
    flowRuleParameter            Integer32
    }

flowRuleSet OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "Selects a rule set from the array of rule sets."
    ::= { flowRuleEntry 1 }

flowRuleIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The index into the Rule table.  N.B: These values will
        often be consecutive, given the fall-through semantics of
        processing the table."
    ::= { flowRuleEntry 2 }

flowRuleSelector OBJECT-TYPE
    SYNTAX  RuleAttributeNumber
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "Indicates the attribute to be matched.

        null(0) is a special case; null rules always succeed.

        v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
        variables, each of which can hold the name (i.e. selector



Brownlee                      Experimental                     [Page 32]

RFC 2064                       Meter MIB                    January 1997


        value) of an address attribute.  When one of these is used
        as a selector, its value specifies the attribute to be
        tested.  Variable values are set by an Assign action."
    ::= { flowRuleEntry 3 }

flowRuleMask OBJECT-TYPE
    SYNTAX  RuleAddress
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "The initial mask used to compute the desired value.  If the
        mask is zero the rule's test will always succeed."
    ::= { flowRuleEntry 4 }

flowRuleMatchedValue OBJECT-TYPE
    SYNTAX  RuleAddress
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "The resulting value to be matched for equality.
        Specifically, if the attribute chosen by the flowRuleSelector
        logically ANDed with the mask specified by the flowRuleMask
        equals the value specified in the flowRuleMatchedValue, then
        continue processing the table entry based on the action
        specified by the flowRuleAction entry.  Otherwise, proceed to
        the next entry in the rule table."
    ::= { flowRuleEntry 5 }

flowRuleAction OBJECT-TYPE
    SYNTAX  ActionNumber
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "The action to be taken if this rule's test succeeds, or if
        the meter's 'test' flag is off.  Actions are opcodes for the
        meter's Packet Matching Engine; details are given in the
        'Traffic Flow Measurement: Architecture' document [9]."
    ::= { flowRuleEntry 6 }

flowRuleParameter OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        "A parameter value providing extra information for the
        rule's action."
    ::= { flowRuleEntry 7 }




Brownlee                      Experimental                     [Page 33]

RFC 2064                       Meter MIB                    January 1997


--
-- Traffic Flow Meter conformance statement
--

flowMIBCompliances
    OBJECT IDENTIFIER ::= { flowMIBConformance 1 }

flowMIBGroups
    OBJECT IDENTIFIER ::= { flowMIBConformance 2 }

flowControlGroup OBJECT-GROUP
    OBJECTS  {
        flowRuleInfoSize, flowRuleInfoOwner,
            flowRuleInfoTimeStamp, flowRuleInfoStatus,
        flowInterfaceRate,
            flowInterfaceLostPackets,
        flowReaderTimeout, flowReaderOwner,
            flowReaderLastTime, flowReaderPreviousTime,
            flowReaderStatus,
        flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
            flowManagerHighWaterMark,
            flowManagerOwner, flowManagerTimeStamp,
            flowManagerStatus,
        flowFloodMark,
            flowInactivityTimeout,
            flowActiveFlows,
            flowMaxFlows }
    STATUS  current
    DESCRIPTION
        "The control group defines objects which are used to control
        an accounting meter."
    ::= {flowMIBGroups 1 }

flowDataTableGroup OBJECT-GROUP
    OBJECTS  {
        flowDataIndex,
        flowDataStatus,
        flowDataSourceInterface,
        flowDataSourceAdjacentType,
        flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask,
        flowDataSourcePeerType,
        flowDataSourcePeerAddress, flowDataSourcePeerMask,
        flowDataSourceTransType,
        flowDataSourceTransAddress, flowDataSourceTransMask,
        flowDataDestInterface,
        flowDataDestAdjacentType,
        flowDataDestAdjacentAddress, flowDataDestAdjacentMask,
        flowDataDestPeerType,



Brownlee                      Experimental                     [Page 34]

RFC 2064                       Meter MIB                    January 1997


        flowDataDestPeerAddress, flowDataDestPeerMask,
        flowDataDestTransType,
        flowDataDestTransAddress, flowDataDestTransMask,
        flowDataRuleSet,
        flowDataToOctets, flowDataToPDUs,
        flowDataFromOctets, flowDataFromPDUs,
        flowDataFirstTime, flowDataLastActiveTime,
        flowDataSourceClass, flowDataDestClass, flowDataClass,
        flowDataSourceKind, flowDataDestKind, flowDataKind
        }
    STATUS  current
    DESCRIPTION
        "The flow table group defines objects which provide the
        structure for the rule table, including the creation time
        and activity time indexes into it.  In addition it defines
        objects which provide a base set of flow attributes for the
        adjacent, peer and transport layers, together with a flow's
        counters and times.  Finally it defines a flow's class and
        kind attributes, which are set by rule actions."
    ::= {flowMIBGroups 2 }

flowDataScaleGroup OBJECT-GROUP
    OBJECTS  {
        flowManagerCounterWrap,
        flowDataPDUScale, flowDataOctetScale
        }
    STATUS  current
    DESCRIPTION
        "The flow scale group defines objects which specify scale
        factors for counters."
    ::= {flowMIBGroups 3 }

flowDataSubscriberGroup OBJECT-GROUP
    OBJECTS  {
        flowDataSourceSubscriberID, flowDataDestSubscriberID,
        flowDataSessionID
        }
    STATUS  current
    DESCRIPTION
        "The flow subscriber group defines objects which may be used
        to identify the end point(s) of a flow."
    ::= {flowMIBGroups 4 }

flowDataColumnTableGroup OBJECT-GROUP
    OBJECTS  {
        flowColumnActivityAttribute,
        flowColumnActivityTime,
        flowColumnActivityIndex,



Brownlee                      Experimental                     [Page 35]

RFC 2064                       Meter MIB                    January 1997


        flowColumnActivityData
        }
    STATUS  current
    DESCRIPTION
        "The flow column table group defines objects which can be used
        to collect part of a column of attribute values from the flow
        table."
    ::= {flowMIBGroups 5 }

flowRuleTableGroup OBJECT-GROUP
    OBJECTS  {
        flowRuleSelector,
        flowRuleMask, flowRuleMatchedValue,
        flowRuleAction, flowRuleParameter
        }
    STATUS  current
    DESCRIPTION
        "The rule table group 