字号:
INTEGER
}
ifExtnsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
interface for which this entry contains
extended management information. The value
of this object for a particular interface
has the same value as the ifIndex object,
defined in [4,6], for the same interface."
::= { ifExtnsEntry 1 }
ifExtnsChipSet OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the hardware chip
set being used in the interface. The
assignment of OBJECT IDENTIFIERs to various
types of hardware chip sets is managed
by the IANA. If the hardware chip set is
unknown, the object identifier
unknownChipSet OBJECT IDENTIFIER ::= { 0 0 }
is returned. Note that unknownChipSet is a
syntactically valid object identifier, and
any conformant implementation of ASN.1 and
the BER must be able to generate and
SNMP Working Group [Page 6]
RFC 1229 Interface MIB Extensions May 1991
recognize this value."
::= { ifExtnsEntry 2 }
ifExtnsRevWare OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An arbitrary octet string that describes
the firmware version of this interface.
It is intended that this should be human
readable. It must only contain ASCII
printable characters. Typically this
will be the firmware version of the main
interface software."
::= { ifExtnsEntry 3 }
ifExtnsMulticastsTransmittedOks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of frames successfully
transmitted to a subnetwork or link-layer
multicast destination address other than a
broadcast address. For a MAC layer protocol,
this includes both Group and Functional
addresses."
::= { ifExtnsEntry 4 }
ifExtnsBroadcastsTransmittedOks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of frames successfully
transmitted to a subnetwork or link-layer
broadcast addresses. It does not include
frames sent to a multicast address."
::= { ifExtnsEntry 5 }
ifExtnsMulticastsReceivedOks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of frames successfully received
that are directed to an active subnetwork
SNMP Working Group [Page 7]
RFC 1229 Interface MIB Extensions May 1991
or link-layer multicast address (for a MAC
layer protocol, this includes both Group and
Functional addresses). This does not include
frames directed to a broadcast address, nor
frames received with errors."
::= { ifExtnsEntry 6 }
ifExtnsBroadcastsReceivedOks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of frames successfully received
that are directed to a subnetwork or
link-layer broadcast address. This does not
include frames received with errors."
::= { ifExtnsEntry 7 }
ifExtnsPromiscuous OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
ACCESS read-only -- Note: agent implementors are
-- encouraged to extend this
-- access to read-write if that
-- makes sense in their agent.
STATUS mandatory
DESCRIPTION
"This object has a value of false(2) if
this interface only accepts packets/frames
that are addressed to this station. This
object has a value of true(1) when the
station accepts all packets/frames
transmitted on the media. The value
true(1) is only legal on certain types of
media. If legal, setting this object to a
value of true(1) may require the interface
to be reset before becoming effective."
::= { ifExtnsEntry 8 }
--
-- Generic Interface Test Table
--
-- This group of objects is optional, but if the table is
-- implemented, all objects in the table must be implemented.
SNMP Working Group [Page 8]
RFC 1229 Interface MIB Extensions May 1991
ifExtnsTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfExtnsTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains one entry per interface."
::= { ifExtensions 2 }
ifExtnsTestEntry OBJECT-TYPE
SYNTAX IfExtnsTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing objects for invoking
tests on an interface."
INDEX { ifExtnsTestIfIndex }
::= { ifExtnsTestTable 1 }
IfExtnsTestEntry ::=
SEQUENCE {
ifExtnsTestIfIndex
INTEGER,
ifExtnsTestCommunity
OCTET STRING,
ifExtnsTestRequestId
INTEGER,
ifExtnsTestType
OBJECT IDENTIFIER,
ifExtnsTestResult
INTEGER,
ifExtnsTestCode
OBJECT IDENTIFIER
}
ifExtnsTestIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
interface for which this entry contains
information on interface tests. The value
of this object for a particular interface
has the same value as the ifIndex object,
defined in [4,6], for the same interface."
::= { ifExtnsTestEntry 1 }
SNMP Working Group [Page 9]
RFC 1229 Interface MIB Extensions May 1991
ifExtnsTestCommunity OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the name of the SNMP
authentication community [5] which was used
to authenticate the SNMP Message which invoked
the current or most recent test on this
interface. If the authentication community
is unknown or undefined, this value contains
the zero-length string."
::= { ifExtnsTestEntry 2 }
ifExtnsTestRequestId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the value of the
request-id field in the SNMP PDU [5] which
invoked the current or most recent test on
this interface. If the request-id is
unknown or undefined, this value contains
the value zero."
::= { ifExtnsTestEntry 3 }
ifExtnsTestType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A control variable used to start and stop
operator-initiated interface tests.
Most OBJECT IDENTIFIER values assigned
to tests are defined elsewhere, in associ-
ation with specific types of interface.
However, this document assigns a value for
a full-duplex loopback test, and defines the
special meanings of the subject identifier:
noTest OBJECT IDENTIFIER ::= { 0 0 }
When the value noTest is written to this
object, no action is taken unless a test is
in progress, in which case the test is
aborted. Writing any other value to this
object is only valid when no test is
SNMP Working Group [Page 10]
RFC 1229 Interface MIB Extensions May 1991
currently in progress, in which case the
indicated test is initiated.
Note that noTest is a syntactically valid
object identifier, and any conformant
implementation of ASN.1 and BER must be able
to generate and recognize this value.
When read, this object always returns
the most recent value that ifExtnsTestType
was set to. If it has not been set since
the last initialization of the network
management subsystem on the agent, a value
of noTest is returned."
::= { ifExtnsTestEntry 4 }
wellKnownTests OBJECT IDENTIFIER ::= { ifExtensions 4 }
-- full-duplex loopback test
testFullDuplexLoopBack OBJECT IDENTIFIER ::=
{ wellKnownTests 1 }
ifExtnsTestResult OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- no test yet requested
success(2),
inProgress(3),
notSupported(4),
unAbleToRun(5), -- due to state of system
aborted(6),
failed(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the result of the most