rfc2003.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 788 行 · 第 1/3 页
TXT
788 行
relay ICMP messages to the source of the original unencapsulated
datagram. By maintaining "soft state" about the MTU of the
tunnel, the encapsulator can return correct ICMP Datagram Too Big
messages to the original sender of the unencapsulated datagram to
support its own Path MTU Discovery. In this case, the MTU that
is conveyed to the original sender by the encapsulator SHOULD
be the MTU of the tunnel minus the size of the encapsulating
IP header. This will avoid fragmentation of the original IP
datagram by the encapsulator.
- If the source of the original unencapsulated datagram is
not doing Path MTU Discovery, it is still desirable for the
encapsulator to know the MTU of the tunnel. In particular, it is
much better to fragment the original datagram when encapsulating,
than to allow the encapsulated datagram to be fragmented.
Fragmenting the original datagram can be done by the encapsulator
without special buffer requirements and without the need to
keep reassembly state in the decapsulator. By contrast, if
the encapsulated datagram is fragmented, then the decapsulator
must reassemble the fragmented (encapsulated) datagram before
decapsulating it, requiring reassembly state and buffer space
within the decapsulator.
Thus, the encapsulator SHOULD normally do Path MTU Discovery,
requiring it to send all datagrams into the tunnel with the "Don't
Fragment" bit set in the outer IP header. However there are problems
with this approach. When the original sender sets the "Don't
Fragment" bit, the sender can react quickly to any returned ICMP
Datagram Too Big error message by retransmitting the original
datagram. On the other hand, suppose that the encapsulator receives
an ICMP Datagram Too Big message from within the tunnel. In that
case, if the original sender of the unencapsulated datagram had not
Perkins Standards Track [Page 10]
RFC 2003 IP-within-IP October 1996
set the "Don't Fragment" bit, there is nothing sensible that the
encapsulator can do to let the original sender know of the error.
The encapsulator MAY keep a copy of the sent datagram whenever it
tries increasing the tunnel MTU, in order to allow it to fragment and
resend the datagram if it gets a Datagram Too Big response.
Alternatively the encapsulator MAY be configured for certain types of
datagrams not to set the "Don't Fragment" bit when the original
sender of the unencapsulated datagram has not set the "Don't
Fragment" bit.
5.2. Congestion
An encapsulator might receive indications of congestion from the
tunnel, for example, by receiving ICMP Source Quench messages from
nodes within the tunnel. In addition, certain link layers and
various protocols not related to the Internet suite of protocols
might provide such indications in the form of a Congestion
Experienced [6] flag. The encapsulator SHOULD reflect conditions of
congestion in its "soft state" for the tunnel, and when subsequently
forwarding datagrams into the tunnel, the encapsulator SHOULD use
appropriate means for controlling congestion [3]; However, the
encapsulator SHOULD NOT send ICMP Source Quench messages to the
original sender of the unencapsulated datagram.
6. Security Considerations
IP encapsulation potentially reduces the security of the Internet,
and care needs to be taken in the implementation and deployment of IP
encapsulation. For example, IP encapsulation makes it difficult for
border routers to filter datagrams based on header fields. In
particular, the original values of the Source Address, Destination
Address, and Protocol fields in the IP header, and the port numbers
used in any transport header within the datagram, are not located in
their normal positions within the datagram after encapsulation.
Since any IP datagram can be encapsulated and passed through a
tunnel, such filtering border routers need to carefully examine all
datagrams.
6.1. Router Considerations
Routers need to be aware of IP encapsulation protocols in order to
correctly filter incoming datagrams. It is desirable that such
filtering be integrated with IP authentication [1]. Where IP
authentication is used, encapsulated packets might be allowed to
enter an organization when the encapsulating (outer) packet or the
encapsulated (inner) packet is sent by an authenticated, trusted
source. Encapuslated packets containing no such authentication
represent a potentially large security risk.
Perkins Standards Track [Page 11]
RFC 2003 IP-within-IP October 1996
IP datagrams which are encapsulated and encrypted [2] might also pose
a problem for filtering routers. In this case, the router can filter
the datagram only if it shares the security association used for the
encryption. To allow this sort of encryption in environments in
which all packets need to be filtered (or at least accounted for), a
mechanism must be in place for the receiving node to securely
communicate the security association to the border router. This
might, more rarely, also apply to the security association used for
outgoing datagrams.
6.2. Host Considerations
Host implementations that are capable of receiving encapsulated IP
datagrams SHOULD admit only those datagrams fitting into one or more
of the following categories:
- The protocol is harmless: source address-based authentication is
not needed.
- The encapsulating (outer) datagram comes from an authentically
identified, trusted source. The authenticity of the source could
be established by relying on physical security in addition to
border router configuration, but is more likely to come from use
of the IP Authentication header [1].
- The encapuslated (inner) datagram includes an IP Authentication
header.
- The encapsulated (inner) datagram is addressed to a network
interface belonging to the decapsulator, or to a node with which
the decapsulator has entered into a special relationship for
delivering such encapsulated datagrams.
Some or all of this checking could be done in border routers rather
than the receiving node, but it is better if border router checks are
used as backup, rather than being the only check.
Perkins Standards Track [Page 12]
RFC 2003 IP-within-IP October 1996
7. Acknowledgements
Parts of Sections 3 and 5 of this document were taken from portions
(authored by Bill Simpson) of earlier versions of the Mobile IP
Internet Draft [8]. The original text for section 6 (Security
Considerations) was contributed by Bob Smart. Good ideas have also
been included from RFC 1853 [11], also authored by Bill Simpson.
Thanks also to Anders Klemets for finding mistakes and suggesting
improvements to the draft. Finally, thanks to David Johnson for
going over the draft with a fine-toothed comb, finding mistakes,
improving consistency, and making many other improvements to the
draft.
References
[1] Atkinson, R., "IP Authentication Header", RFC 1826, August 1995.
[2] Atkinson, R., "IP Encapsulating Security Payload", RFC 1827,
August 1995.
[3] Baker, F., Editor, "Requirements for IP Version 4 Routers", RFC
1812, June 1995.
[4] Gilligan, R., Nordmark, E., and B. Hinden, "IPAE: The SIPP
Interoperability and Transition Mechanism", Work in Progress.
[5] Knowles, S., "IESG Advice from Experience with Path MTU
Discovery", RFC 1435, March 1993.
[6] Mankin, A., and K. Ramakrishnan, "Gateway Congestion Control
Survey", RFC 1254, August 1991.
[7] Mogul, J., and S. Deering, "Path MTU Discovery", RFC 1191,
November 1990.
[8] Perkins, C., Editor, "IP Mobility Support", RFC 2002,
October 1996.
[9] Postel, J., Editor, "Internet Control Message Protocol", STD 5,
RFC 792, September 1981.
[10] Postel, J., Editor, "Internet Protocol", STD 5, RFC 791,
September 1981.
[11] Simpson, W., "IP in IP Tunneling", RFC 1853, October 1995.
Perkins Standards Track [Page 13]
RFC 2003 IP-within-IP October 1996
Author's Address
Questions about this memo can be directed to:
Charles Perkins
Room H3-D34
T. J. Watson Research Center
IBM Corporation
30 Saw Mill River Rd.
Hawthorne, NY 10532
Work: +1-914-784-7350
Fax: +1-914-784-6205
EMail: perk@watson.ibm.com
The working group can be contacted via the current chair:
Jim Solomon
Motorola, Inc.
1301 E. Algonquin Rd.
Schaumburg, IL 60196
Work: +1-847-576-2753
EMail: solomon@comm.mot.com
Perkins Standards Track [Page 14]
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?