         frAtmIwfMIB MODULE-IDENTITY
             LAST-UPDATED "200009280000Z" -- September 28, 2000
             ORGANIZATION "IETF Frame Relay Service MIB Working Group"
             CONTACT-INFO
                 "WG Charter:
                    http://www.ietf.org/html.charters/frnetmib-charter
                  WG-email:
                    frnetmib@sunroof.eng.sun.com
                  Subscribe:
                    frnetmib-request@sunroof.eng.sun.com
                  Email Archive:
                    ftp://ftp.ietf.org/ietf-mail-archive/frnetmib

                  Chair:      Andy Malis
                              Vivace Networks, Inc.
                  Email:      Andy.Malis@vivacenetworks.com

                  WG editor:  Kenneth Rehbehn
                              Megisto Systems, Inc.
                  Email:      krehbehn@megisto.com

                  Co-author:  Orly Nicklass
                              RAD Data Communications Ltd.
                  EMail:      orly_n@rad.co.il

                  Co-author:  George Mouradian
                              AT&T Labs
                  EMail:      gvm@att.com"

             DESCRIPTION
                     "The MIB module for monitoring and controlling the
                     Frame Relay/ATM PVC Service Interworking
                     Function."

             --
             -- Revision History
             --



Rehbehn, et al.             Standards Track                    [Page 12]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


             REVISION "200009280000Z"
             DESCRIPTION
                  "Published as RFC 2955"

         ::= { mib-2 86 }

         --
         -- Object Identifiers
         --
            frAtmIwfMIBObjects      OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 1 }

            frAtmIwfTraps           OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 2 }
            frAtmIwfTrapsPrefix     OBJECT IDENTIFIER
                                         ::= { frAtmIwfTraps 0 }

            frAtmIwfConformance     OBJECT IDENTIFIER
                                         ::= { frAtmIwfMIB 3 }
            frAtmIwfGroups          OBJECT IDENTIFIER
                                         ::= { frAtmIwfConformance 1 }
            frAtmIwfCompliances     OBJECT IDENTIFIER
                                         ::= { frAtmIwfConformance 2 }

         --
         --  The FR/ATM PVC Service IWF Group
         --
         --      The Frame Relay/ATM PVC Service Interworking Function
         --      Connection Table contains all connections utilizing
         --      the interworking function.
         --

         frAtmIwfConnIndexNext OBJECT-TYPE
              SYNTAX         Integer32 (0..2147483647)
              MAX-ACCESS     read-only
              STATUS         current
              DESCRIPTION
                     "This object contains an appropriate value to be
                     used for frAtmIwfConnIndex  when creating entries
                     in the frAtmIwfConnectionTable. The value 0
                     indicates that no unassigned entries are
                     available. To obtain the frAtmIwfConnIndexNext
                     value for a new entry, the manager issues a
                     management protocol retrieval operation to obtain
                     the current value of this object.  After each
                     retrieval, the agent should modify the value to
                     the next unassigned index."
              ::= { frAtmIwfMIBObjects 1 }



Rehbehn, et al.             Standards Track                    [Page 13]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


         frAtmIwfConnectionTable OBJECT-TYPE
             SYNTAX      SEQUENCE OF FrAtmIwfConnectionEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A table in which each row represents a Frame
                     Relay/ATM interworking connection."
             ::= { frAtmIwfMIBObjects 2 }

         frAtmIwfConnectionEntry OBJECT-TYPE
             SYNTAX      FrAtmIwfConnectionEntry
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The FrAtmIwfConnectionEntry provides an entry for
                     an interworking connection between a frame relay
                     PVC and one or more ATM PVCs, or an ATM PVC and
                     one or more frame relay PVCs.  A single frame
                     relay PVC connected to a single ATM PVC is
                     referred to as a `point-to-point' connection and
                     is represented by a single row in the FR/ATM IWF
                     Connection Table.  The case of a single frame
                     relay PVC connected to multiple ATM PVCs (or
                     single ATM PVC connected to multiple frame relay
                     PVCs) is referred to as a `point-to-multipoint'
                     connection and is represented by multiple rows in
                     the FR/ATM IWF Connection Table.

                     The object frAtmIwfConnIndex uniquely identifies
                     each point-to-point or point-to-multipoint
                     connection.  The manager obtains the
                     frAtmIwfConnIndex value by reading the
                     frAtmIwfConnIndexNext object.

                     After a frAtmIwfConnIndex is assigned for the
                     connection, the manager creates one or more rows
                     in the Cross Connect Table; one for each cross-
                     connection between the frame relay PVC and an ATM
                     PVC. In the case of `point-to-multipoint'
                     connections, all rows are indexed by the same
                     frAtmIwfConnIndex value and MUST refer to the same
                     frame relay PVC or ATM PVC respectively.  An entry
                     can be created only when at least one pair of
                     frame relay and ATM PVCs exist.

                     A row can be established by one-step set-request
                     with all required parameter values and
                     frAtmIwfConnRowStatus set to createAndGo(4). The



Rehbehn, et al.             Standards Track                    [Page 14]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     Agent should perform all error checking as needed.
                     A pair of cross-connected PVCs, as identified by a
                     particular value of the indexes, is released by
                     setting frAtmIwfConnRowStatus to destroy(6). The
                     Agent may release all associated resources. The
                     manager may remove the related PVCs thereafter.
                     Indexes are persistent across reboots of the
                     system."
             INDEX   { frAtmIwfConnIndex,
                       frAtmIwfConnAtmPort,
                       frAtmIwfConnVpi,
                       frAtmIwfConnVci,
                       frAtmIwfConnFrPort,
                       frAtmIwfConnDlci
                     }
             ::= { frAtmIwfConnectionTable 1 }

         FrAtmIwfConnectionEntry ::=
             SEQUENCE {
                 frAtmIwfConnIndex                      Integer32,
                 frAtmIwfConnAtmPort                    InterfaceIndex,
                 frAtmIwfConnVpi                        AtmVpIdentifier,
                 frAtmIwfConnVci                        AtmVcIdentifier,
                 frAtmIwfConnFrPort                     InterfaceIndex,
                 frAtmIwfConnDlci                       Integer32,
                 frAtmIwfConnRowStatus                  RowStatus,
                 frAtmIwfConnAdminStatus                INTEGER,
                 frAtmIwfConnAtm2FrOperStatus           INTEGER,
                 frAtmIwfConnAtm2FrLastChange           TimeStamp,
                 frAtmIwfConnFr2AtmOperStatus           INTEGER,
                 frAtmIwfConnFr2AtmLastChange           TimeStamp,
                 frAtmIwfConnectionDescriptor           Integer32,
                 frAtmIwfConnFailedFrameTranslate       Counter32,
                 frAtmIwfConnOverSizedFrames            Counter32,
                 frAtmIwfConnFailedAal5PduTranslate     Counter32,
                 frAtmIwfConnOverSizedSDUs              Counter32,
                 frAtmIwfConnCrcErrors                  Counter32,
                 frAtmIwfConnSarTimeOuts                Counter32
         }

         frAtmIwfConnIndex  OBJECT-TYPE
             SYNTAX      Integer32  (1..2147483647)
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "A unique value for each point-to-point or point-
                     to-multipoint connection.  The manager obtains the
                     frAtmIwfConnIndex value by reading the



Rehbehn, et al.             Standards Track                    [Page 15]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


                     frAtmIwfConnIndexNext object.  A point-to-
                     multipoint connection will be represented in the
                     frAtmIwfConnectionTable with multiple entries that
                     share the same frAtmIwfConnIndex value."
             ::= { frAtmIwfConnectionEntry 1 }

         frAtmIwfConnAtmPort OBJECT-TYPE
             SYNTAX      InterfaceIndex
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The index in the ifTable that identifies the ATM
                     port for this interworking connection."
             ::= { frAtmIwfConnectionEntry 2 }

         frAtmIwfConnVpi OBJECT-TYPE
             SYNTAX      AtmVpIdentifier
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The VPI of the ATM PVC end point for this
                      interworking connection."
             ::= { frAtmIwfConnectionEntry 3 }

         frAtmIwfConnVci OBJECT-TYPE
             SYNTAX      AtmVcIdentifier
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The VCI of the ATM PVC end point for this
                     interworking
                      connection."
             ::= { frAtmIwfConnectionEntry 4 }

         frAtmIwfConnFrPort OBJECT-TYPE
             SYNTAX      InterfaceIndex
             MAX-ACCESS  not-accessible
             STATUS      current
             DESCRIPTION
                     "The index in the ifTable that identifies the
                     frame relay port for this interworking
                     connection."
             ::= { frAtmIwfConnectionEntry 5 }

         frAtmIwfConnDlci OBJECT-TYPE
             SYNTAX      Integer32 (16..4194303)
             MAX-ACCESS  not-accessible
             STATUS      current



Rehbehn, et al.             Standards Track                    [Page 16]

RFC 2955           FR to ATM Service Interworking MIB       October 2000


             DESCRIPTION
                     "The DLCI that identifies the frame relay PVC end
                     point for this interworking connection."
             ::= { frAtmIwfConnectionEntry 6 }

         frAtmIwfConnRowStatus OBJECT-TYPE
             SYNTAX      RowStatus
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The table row may be created with
                     'createAndWait(5)' or 'createAndGo(4)'.
                     To activate a connection entry, a valid connection
                     descriptor MUST be established in the
                     frAtmIwfConnectionDescriptor object.

                     This object is set to 'destroy(6)' to delete the
                     table row.  Before the table row is destroyed, the
                     OperStatus/AdminStatus of the corresponding
                     endpoints MUST be 'down(2)'.  The deactivation of
                     the ATM endpoint MAY occur as a side-effect of
                     deleting the FR/ATM IWF cross-connection table
                     row.  Otherwise, 'destroy(6)' operation MUST fail
                     (error code 'inconsistentValue')."
             ::= { frAtmIwfConnectionEntry 7 }

         frAtmIwfConnAdminStatus OBJECT-TYPE
             SYNTAX      INTEGER { up(1), down(2) }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "The desired operational state for this FR/ATM
                     interworked connection.

                     up(1)       = Activate the connection. Before the
                                   activation can be completed, the
                                   OperStatus/AdminStatus of the
                                   corresponding endpoints MUST be
                                   'up(1)'.  The activation of the
                                   corresponding endpoints MAY occur as
                                   a side-effect of activating the
                                   FR/ATM IWF cross-connection.

                     down(2)     = Deactivate the connection. Before
                                   the deactivation can be completed,
                                   the atmVclAdminStatus of the

⌨️ 快捷键说明