📄 rfc2955.txt
字号:
frAtmIwfMIB MODULE-IDENTITY
LAST-UPDATED "200009280000Z" -- September 28, 2000
ORGANIZATION "IETF Frame Relay Service MIB Working Group"
CONTACT-INFO
"WG Charter:
http://www.ietf.org/html.charters/frnetmib-charter
WG-email:
frnetmib@sunroof.eng.sun.com
Subscribe:
frnetmib-request@sunroof.eng.sun.com
Email Archive:
ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
Chair: Andy Malis
Vivace Networks, Inc.
Email: Andy.Malis@vivacenetworks.com
WG editor: Kenneth Rehbehn
Megisto Systems, Inc.
Email: krehbehn@megisto.com
Co-author: Orly Nicklass
RAD Data Communications Ltd.
EMail: orly_n@rad.co.il
Co-author: George Mouradian
AT&T Labs
EMail: gvm@att.com"
DESCRIPTION
"The MIB module for monitoring and controlling the
Frame Relay/ATM PVC Service Interworking
Function."
--
-- Revision History
--
Rehbehn, et al. Standards Track [Page 12]
RFC 2955 FR to ATM Service Interworking MIB October 2000
REVISION "200009280000Z"
DESCRIPTION
"Published as RFC 2955"
::= { mib-2 86 }
--
-- Object Identifiers
--
frAtmIwfMIBObjects OBJECT IDENTIFIER
::= { frAtmIwfMIB 1 }
frAtmIwfTraps OBJECT IDENTIFIER
::= { frAtmIwfMIB 2 }
frAtmIwfTrapsPrefix OBJECT IDENTIFIER
::= { frAtmIwfTraps 0 }
frAtmIwfConformance OBJECT IDENTIFIER
::= { frAtmIwfMIB 3 }
frAtmIwfGroups OBJECT IDENTIFIER
::= { frAtmIwfConformance 1 }
frAtmIwfCompliances OBJECT IDENTIFIER
::= { frAtmIwfConformance 2 }
--
-- The FR/ATM PVC Service IWF Group
--
-- The Frame Relay/ATM PVC Service Interworking Function
-- Connection Table contains all connections utilizing
-- the interworking function.
--
frAtmIwfConnIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to be
used for frAtmIwfConnIndex when creating entries
in the frAtmIwfConnectionTable. The value 0
indicates that no unassigned entries are
available. To obtain the frAtmIwfConnIndexNext
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the current value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index."
::= { frAtmIwfMIBObjects 1 }
Rehbehn, et al. Standards Track [Page 13]
RFC 2955 FR to ATM Service Interworking MIB October 2000
frAtmIwfConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAtmIwfConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table in which each row represents a Frame
Relay/ATM interworking connection."
::= { frAtmIwfMIBObjects 2 }
frAtmIwfConnectionEntry OBJECT-TYPE
SYNTAX FrAtmIwfConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FrAtmIwfConnectionEntry provides an entry for
an interworking connection between a frame relay
PVC and one or more ATM PVCs, or an ATM PVC and
one or more frame relay PVCs. A single frame
relay PVC connected to a single ATM PVC is
referred to as a `point-to-point' connection and
is represented by a single row in the FR/ATM IWF
Connection Table. The case of a single frame
relay PVC connected to multiple ATM PVCs (or
single ATM PVC connected to multiple frame relay
PVCs) is referred to as a `point-to-multipoint'
connection and is represented by multiple rows in
the FR/ATM IWF Connection Table.
The object frAtmIwfConnIndex uniquely identifies
each point-to-point or point-to-multipoint
connection. The manager obtains the
frAtmIwfConnIndex value by reading the
frAtmIwfConnIndexNext object.
After a frAtmIwfConnIndex is assigned for the
connection, the manager creates one or more rows
in the Cross Connect Table; one for each cross-
connection between the frame relay PVC and an ATM
PVC. In the case of `point-to-multipoint'
connections, all rows are indexed by the same
frAtmIwfConnIndex value and MUST refer to the same
frame relay PVC or ATM PVC respectively. An entry
can be created only when at least one pair of
frame relay and ATM PVCs exist.
A row can be established by one-step set-request
with all required parameter values and
frAtmIwfConnRowStatus set to createAndGo(4). The
Rehbehn, et al. Standards Track [Page 14]
RFC 2955 FR to ATM Service Interworking MIB October 2000
Agent should perform all error checking as needed.
A pair of cross-connected PVCs, as identified by a
particular value of the indexes, is released by
setting frAtmIwfConnRowStatus to destroy(6). The
Agent may release all associated resources. The
manager may remove the related PVCs thereafter.
Indexes are persistent across reboots of the
system."
INDEX { frAtmIwfConnIndex,
frAtmIwfConnAtmPort,
frAtmIwfConnVpi,
frAtmIwfConnVci,
frAtmIwfConnFrPort,
frAtmIwfConnDlci
}
::= { frAtmIwfConnectionTable 1 }
FrAtmIwfConnectionEntry ::=
SEQUENCE {
frAtmIwfConnIndex Integer32,
frAtmIwfConnAtmPort InterfaceIndex,
frAtmIwfConnVpi AtmVpIdentifier,
frAtmIwfConnVci AtmVcIdentifier,
frAtmIwfConnFrPort InterfaceIndex,
frAtmIwfConnDlci Integer32,
frAtmIwfConnRowStatus RowStatus,
frAtmIwfConnAdminStatus INTEGER,
frAtmIwfConnAtm2FrOperStatus INTEGER,
frAtmIwfConnAtm2FrLastChange TimeStamp,
frAtmIwfConnFr2AtmOperStatus INTEGER,
frAtmIwfConnFr2AtmLastChange TimeStamp,
frAtmIwfConnectionDescriptor Integer32,
frAtmIwfConnFailedFrameTranslate Counter32,
frAtmIwfConnOverSizedFrames Counter32,
frAtmIwfConnFailedAal5PduTranslate Counter32,
frAtmIwfConnOverSizedSDUs Counter32,
frAtmIwfConnCrcErrors Counter32,
frAtmIwfConnSarTimeOuts Counter32
}
frAtmIwfConnIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each point-to-point or point-
to-multipoint connection. The manager obtains the
frAtmIwfConnIndex value by reading the
Rehbehn, et al. Standards Track [Page 15]
RFC 2955 FR to ATM Service Interworking MIB October 2000
frAtmIwfConnIndexNext object. A point-to-
multipoint connection will be represented in the
frAtmIwfConnectionTable with multiple entries that
share the same frAtmIwfConnIndex value."
::= { frAtmIwfConnectionEntry 1 }
frAtmIwfConnAtmPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index in the ifTable that identifies the ATM
port for this interworking connection."
::= { frAtmIwfConnectionEntry 2 }
frAtmIwfConnVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI of the ATM PVC end point for this
interworking connection."
::= { frAtmIwfConnectionEntry 3 }
frAtmIwfConnVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI of the ATM PVC end point for this
interworking
connection."
::= { frAtmIwfConnectionEntry 4 }
frAtmIwfConnFrPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index in the ifTable that identifies the
frame relay port for this interworking
connection."
::= { frAtmIwfConnectionEntry 5 }
frAtmIwfConnDlci OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
Rehbehn, et al. Standards Track [Page 16]
RFC 2955 FR to ATM Service Interworking MIB October 2000
DESCRIPTION
"The DLCI that identifies the frame relay PVC end
point for this interworking connection."
::= { frAtmIwfConnectionEntry 6 }
frAtmIwfConnRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The table row may be created with
'createAndWait(5)' or 'createAndGo(4)'.
To activate a connection entry, a valid connection
descriptor MUST be established in the
frAtmIwfConnectionDescriptor object.
This object is set to 'destroy(6)' to delete the
table row. Before the table row is destroyed, the
OperStatus/AdminStatus of the corresponding
endpoints MUST be 'down(2)'. The deactivation of
the ATM endpoint MAY occur as a side-effect of
deleting the FR/ATM IWF cross-connection table
row. Otherwise, 'destroy(6)' operation MUST fail
(error code 'inconsistentValue')."
::= { frAtmIwfConnectionEntry 7 }
frAtmIwfConnAdminStatus OBJECT-TYPE
SYNTAX INTEGER { up(1), down(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The desired operational state for this FR/ATM
interworked connection.
up(1) = Activate the connection. Before the
activation can be completed, the
OperStatus/AdminStatus of the
corresponding endpoints MUST be
'up(1)'. The activation of the
corresponding endpoints MAY occur as
a side-effect of activating the
FR/ATM IWF cross-connection.
down(2) = Deactivate the connection. Before
the deactivation can be completed,
the atmVclAdminStatus of the
⌨️ 快捷键说明