rfc1212.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 1,067 行 · 第 1/3 页
TXT
1,067 行
framework.
The first step is to construct a skeletal MIB module, e.g.,
RFC1213-MIB DEFINITIONS ::= BEGIN
IMPORTS
experimental, OBJECT-TYPE, Counter
FROM RFC1155-SMI;
-- contact IANA for actual number
root OBJECT IDENTIFIER ::= { experimental xx }
END
SNMP Working Group [Page 13]
RFC 1212 Concise MIB Definitions March 1991
The next step is to categorize the objects into groups. For
experimental MIBs, optional objects are permitted. However, when a
MIB module is placed in the Internet-standard space, these optional
objects are either removed, or placed in a optional group, which, if
implemented, all objects in the group must be implemented. For the
first pass, it is wisest to simply ignore any optional objects in the
original MIB: experience shows it is better to define a core MIB
module first, containing only essential objects; later, if experience
demands, other objects can be added.
It must be emphasized that groups are "units of conformance" within a
MIB: everything in a group is "mandatory" and implementations do
either whole groups or none.
5.1. Managed Object Mapping
Next for each managed object class, determine whether there can exist
multiple instances of that managed object class. If not, then for
each of its attributes, use the OBJECT-TYPE macro to make an
equivalent definition.
Otherwise, if multiple instances of the managed object class can
exist, then define a conceptual table having conceptual rows each
containing a columnar object for each of the managed object class's
attributes. If the managed object class is contained within the
containment tree of another managed object class, then the assignment
of an object type is normally required for each of the "distinguished
attributes" of the containing managed object class. If they do not
already exist within the MIB module, then they can be added via the
definition of additional columnar objects in the conceptual row
corresponding to the contained managed object class.
In defining a conceptual row, it is useful to consider the
optimization of network management operations which will act upon its
columnar objects. In particular, it is wisest to avoid defining more
columnar objects within a conceptual row, than can fit in a single
PDU. As a rule of thumb, a conceptual row should contain no more
than approximately 20 objects. Similarly, or as a way to abide by
the "20 object guideline", columnar objects should be grouped into
tables according to the expected grouping of network management
operations upon them. As such, the content of conceptual rows should
reflect typical access scenarios, e.g., they should be organized
along functional lines such as one row for statistics and another row
for parameters, or along usage lines such as commonly-needed objects
versus rarely-needed objects.
On the other hand, the definition of conceptual rows where the number
of columnar objects used as indexes outnumbers the number used to
SNMP Working Group [Page 14]
RFC 1212 Concise MIB Definitions March 1991
hold information, should also be avoided. In particular, the
splitting of a managed object class's attributes into many conceptual
tables should not be used as a way to obtain the same degree of
flexibility/complexity as is often found in MIB's with a myriad of
optionals.
5.1.1. Mapping to the SYNTAX clause
When mapping to the SYNTAX clause of the OBJECT-type macro:
(1) An object with BOOLEAN syntax becomes an INTEGER taking
either of values true(1) or false(2).
(2) An object with ENUMERATED syntax becomes an INTEGER,
taking any of the values given.
(3) An object with BIT STRING syntax containing no more than
32 bits becomes an INTEGER defined as a sum; otherwise if
more than 32 bits are present, the object becomes an
OCTET STRING, with the bits numbered from left-to-right,
in which the least significant bits of the last octet may
be "reserved for future use".
(4) An object with a character string syntax becomes either
an OCTET STRING or a DisplayString, depending on the
repertoire of the character string.
(5) An non-tabular object with a complex syntax, such as REAL
or EXTERNAL, must be decomposed, usually into an OCTET
STRING (if sensible). As a rule, any object with a
complicated syntax should be avoided.
(6) Tabular objects must be decomposed into rows of columnar
objects.
5.1.2. Mapping to the ACCESS clause
This is straight-forward.
5.1.3. Mapping to the STATUS clause
This is usually straight-forward; however, some osified-MIBs use the
term "recommended". In this case, a choice must be made between
"mandatory" and "optional".
5.1.4. Mapping to the DESCRIPTION clause
This is straight-forward: simply copy the text, making sure that any
SNMP Working Group [Page 15]
RFC 1212 Concise MIB Definitions March 1991
embedded double quotation marks are sanitized (i.e., replaced with
single-quotes or removed).
5.1.5. Mapping to the REFERENCE clause
This is straight-forward: simply include a textual reference to the
object being mapped, the document which defines the object, and
perhaps a page number in the document.
5.1.6. Mapping to the INDEX clause
Decide how instance-identifiers for columnar objects are to be formed
and define this clause accordingly.
5.1.7. Mapping to the DEFVAL clause
Decide if a meaningful default value can be assigned to the object
being mapped, and if so, define the DEFVAL clause accordingly.
5.2. Action Mapping
Actions are modeled as read-write objects, in which writing a
particular value results in the action taking place.
5.2.1. Mapping to the SYNTAX clause
Usually an INTEGER syntax is used with a distinguished value provided
for each action that the object provides access to. In addition,
there is usually one other distinguished value, which is the one
returned when the object is read.
5.2.2. Mapping to the ACCESS clause
Always use read-write.
5.2.3. Mapping to the STATUS clause
This is straight-forward.
5.2.4. Mapping to the DESCRIPTION clause
This is straight-forward: simply copy the text, making sure that any
embedded double quotation marks are sanitized (i.e., replaced with
single-quotes or removed).
5.2.5. Mapping to the REFERENCE clause
This is straight-forward: simply include a textual reference to the
SNMP Working Group [Page 16]
RFC 1212 Concise MIB Definitions March 1991
action being mapped, the document which defines the action, and
perhaps a page number in the document.
6. Acknowledgements
This document was produced by the SNMP Working Group:
Anne Ambler, Spider
Karl Auerbach, Sun
Fred Baker, ACC
Ken Brinkerhoff
Ron Broersma, NOSC
Jack Brown, US Army
Theodore Brunner, Bellcore
Jeffrey Buffum, HP
John Burress, Wellfleet
Jeffrey D. Case, University of Tennessee at Knoxville
Chris Chiptasso, Spartacus
Paul Ciarfella, DEC
Bob Collet
John Cook, Chipcom
Tracy Cox, Bellcore
James R. Davin, MIT-LCS
Eric Decker, cisco
Kurt Dobbins, Cabletron
Nadya El-Afandi, Network Systems
Gary Ellis, HP
Fred Engle
Mike Erlinger
Mark S. Fedor, PSI
Richard Fox, Synoptics
Karen Frisa, CMU
Chris Gunner, DEC
Fred Harris, University of Tennessee at Knoxville
Ken Hibbard, Xylogics
Ole Jacobsen, Interop
Ken Jones
Satish Joshi, Synoptics
Frank Kastenholz, Racal-Interlan
Shimshon Kaufman, Spartacus
Ken Key, University of Tennessee at Knoxville
Jim Kinder, Fibercom
Alex Koifman, BBN
Christopher Kolb, PSI
Cheryl Krupczak, NCR
Paul Langille, DEC
Peter Lin, Vitalink
John Lunny, TWG
SNMP Working Group [Page 17]
RFC 1212 Concise MIB Definitions March 1991
Carl Malamud
Randy Mayhew, University of Tennessee at Knoxville
Keith McCloghrie, Hughes LAN Systems
Donna McMaster, David Systems
Lynn Monsanto, Sun
Dave Perkins, 3COM
Jim Reinstedler, Ungerman Bass
Anil Rijsinghani, DEC
Kathy Rinehart, Arnold AFB
Kary Robertson
Marshall T. Rose, PSI (chair)
L. Michael Sabo, NCSC
Jon Saperia, DEC
Greg Satz, cisco
Martin Schoffstall, PSI
John Seligson
Steve Sherry, Xyplex
Fei Shu, NEC
Sam Sjogren, TGV
Mark Sleeper, Sparta
Lance Sprung
Mike St.Johns
Bob Stewart, Xyplex
Emil Sturniold
Kaj Tesink, Bellcore
Dean Throop, Data General
Bill Townsend, Xylogics
Maurice Turcotte, Racal-Milgo
Kannan Varadhou
Sudhanshu Verma, HP
Bill Versteeg, Network Research Corporation
Warren Vik, Interactive Systems
David Waitzman, BBN
Steve Waldbusser, CMU
Dan Wintringhan
David Wood
Wengyik Yeong, PSI
Jeff Young, Cray Research
7. References
[1] Cerf, V., "IAB Recommendations for the Development of Internet
Network Management Standards", RFC 1052, NRI, April 1988.
[2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
Group", RFC 1109, NRI, August 1989.
[3] Rose M., and K. McCloghrie, "Structure and Identification of
SNMP Working Group [Page 18]
RFC 1212 Concise MIB Definitions March 1991
Management Information for TCP/IP-based internets", RFC 1155,
Performance Systems International, Hughes LAN Systems, May 1990.
[4] McCloghrie K., and M. Rose, "Management Information Base for
Network Management of TCP/IP-based internets", RFC 1156, Hughes
LAN Systems, Performance Systems International, May 1990.
[5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
Network Management Protocol", RFC 1157, SNMP Research,
Performance Systems International, Performance Systems
International, MIT Laboratory for Computer Science, May 1990.
[6] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1),
International Organization for Standardization International
Standard 8824, December 1987.
[7] Rose M., Editor, "Management Information Base for Network
Management of TCP/IP-based internets: MIB-II", RFC 1213,
Performance Systems International, March 1991.
8. Security Considerations
Security issues are not discussed in this memo.
9. Authors' Addresses
Marshall T. Rose
Performance Systems International
5201 Great America Parkway
Suite 3106
Santa Clara, CA 95054
Phone: +1 408 562 6222
EMail: mrose@psi.com
X.500: rose, psi, us
Keith McCloghrie
Hughes LAN Systems
1225 Charleston Road
Mountain View, CA 94043
1225 Charleston Road
Mountain View, CA 94043
Phone: (415) 966-7934
EMail: kzm@hls.com
SNMP Working Group [Page 19]
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?