rfc1470.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 2,651 行 · 第 1/5 页
TXT
2,651 行
NOCTools2 Working Group [Page 29]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog ARP
NAME
arp
KEYWORDS
routing; ethernet, IP;; UNIX, VMS; free.
ABSTRACT
Arp displays and can modify the internet-to-ethernet
address translations tables used by ARP, the address
resolution protocol.
MECHANISM
The arp program accesses operating system memory to
read the ARP data structures.
CAVEATS
None.
BUGS
None known.
LIMITATIONS
Only the super user can modify ARP entries.
HARDWARE REQUIRED
No restrictions.
SOFTWARE REQUIRED
BSD UNIX or related OS, or VMS.
AVAILABILITY AND CONTACT POINT FOR INFORMATION ABOUT THIS TOOL
Available via anonymous FTP from uunet.uu.net, in
directory bsd-sources/src/etc. Available with 4.xBSD
UNIX and related operating systems. For VMS, available
as part of TGV MultiNet IP software package, as well as
Wollongong's WIN/TCP and Process Software Corporation's
TCPware for VMS.
CONTACT POINT FOR CHANGES TO THIS CATALOG ENTRY
This entry maintained by the NOCtools editors.
Send email to noctools-request@merit.edu.
NOCTools2 Working Group [Page 30]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog AVATAR-SNMP-TOOLKIT
NAME
SNMP Application Development Toolkit
KEYWORDS
manager;;SNMP;;sourcelib.
ABSTRACT
snmpapi is an api toolkit for developing SNMP
applications and agents. The toolkit is simple and
very fast that can be used for any type of
application. It is very well suited for embedded
systems such as bridges or routers. An example MIB II
agent for Sun Sparcstations is provided. snmpapi is
distributed in source form only.
MECHANISM
snmpapi is a library of C functions.
CAVEATS
None.
BUGS
None known.
LIMITATIONS
None.
HARDWARE REQUIRED
No restrictions.
AVAILABILITY
Available now. For more information, send e-mail to
info@avatar.com.
NOCTools2 Working Group [Page 31]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog AVATAR-SUNSNMPD
NAME
sunsnmpd
KEYWORDS
manager;;snmp;sun;.
ABSTRACT
sunsnmpd is a fully supported SNMP agent with MIB II
support for Sun Sparscations running SunOS 4.1 or
higher. sunsnmpd supports both SNMP GET and SET
operations.
MECHANISM
sundnmpd is a daemon process which starts up at boot
time from the rc.local file. It uses /dev/kmem to access
kernel structures.
CAVEATS
None.
BUGS
None known.
LIMITATIONS
Must be started by a super user.
HARDWARE REQUIRED
Sun Sparcstations.
AVAILABILITY
Available now. Site licensing only. For more information,
send e-mail to info@avatar.com.
NOCTools2 Working Group [Page 32]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog ChameLAN-100
NAME
ChameLAN 100
KEYWORDS
analyzer, benchmark, debugger, generator, map,
reference, status, traffic; bridge, DECnet, ethernet,
FDDI, IP, OSI, NFS, ring; eavesdrop, SNMP, X;
standalone, UNIX.
ABSTRACT
Tekelec's ChameLAN 100 is a portable diagnostic system
for monitoring and simulation of FDDI, Ethernet and
Token Ring networks -- simultaneously. Protocol
analysis of multiple topologies, as well as mixed
topoloies simultaneously, is a key feature of
the product family. Tekelec's proprietary FDDI
hardware guarantees complete real-time analysis of
networks and network components at the full ring
bandwidth of 125 Mbps. It passively connects to the
network and captures 100 percent of the data, measures
performance and isolates real-time problems.
The simulation option offers full bandwidth load
generation that allows you to create and simulate any
network condition. It gives you the ability to inject
errors and misformed frames. A set of
confidence tests allow simple evaluation of new
equipment. A ring map feature displays network
topology and status of all nodes via the SMT
process.
Monitoring of FDDI, Ethernet and Token Ring allows the
user to: view network status in real time; view
network, node, or node pair statistics; capture
frames; control capture using trigger and filter
capabilities; view real-time statistics; view captured
frames in decoded format; and view the last frame
transmitted by each station.
The following Real-Time Network Statistics of FDDI,
Ethernet and Token Ring networks is displayed: frame
rate, runts, byte rate, jabbers, CRC/align errors, and
collisions.
Product developers can use the ChameLAN 100 to observe
NOCTools2 Working Group [Page 33]
RFC 1470 FYI: Network Management Tool Catalog June 1993
and control various events to help debug their FDDI,
Ethernet and Token Ring products. End users can
perform real-time monitoring to test and
diagnose problems that may occur when developing,
installing or managing FDDI, Ethernet and Token Ring
networks and network products. End users can use the
ChameLAN 100 to aid in the installation and
maintenance of Ethernet and Token Ring networks. To
isolate specific network trouble spots the ChameLAN
100 uses filtering and triggering techniques for data
capture. Higher level protocol decode includes
TCP/IP, OSI and DECnet protocol suites. Protocol
decode of IPX, SNMP, XTP, and AppleTalk are also
supported. Development of additional protocol decodes
is also under development. The ChameLAN 100 family
also offers a Protocol Management Development System
(PMDS) that enables users to develop custom protocol
decode suites.
The FDDI, Ethernet and Token Ring hardware interfaces
feature independent processing power. Real-time data
is monitored unobtrusively at full bandwidth without
affecting network activity. Real-time data may also
be saved to a 120MB or optional 200MB hard disk drive
for later analysis. FDDI data is captured at 125 megabits
per second (Mbps), Ethernet at 10 Mbps and Token Ring
at 4 or 16 Mbps.
MECHANISM
This portable, standalone unit incorporates the power
of UNIX, X-Windows and Motif. Its UNIX-based
programming interface facilitates development of
customized monitoring and simulation applications. The
ChameLAN 100 may connect to the network at any
location using standard equipment. Standard graphical
Motif/X-Windows and TCP/IP allow remote control
through Ethernet and 10Base T interfaces. Tekelec
also offers a rackmounted model -- ChameLAN 100-X.
Both models can be controlled via a Sun Workstation
remotely.
CAVEATS
none.
BUGS
none known.
NOCTools2 Working Group [Page 34]
RFC 1470 FYI: Network Management Tool Catalog June 1993
LIMITATIONS
none reported.
HARDWARE REQUIRED
None. The ChameLAN 100 is a self-contained unit, and
includes its own interface cards. It installs
into a network with standard interface
connectors.
SOFTWARE REQUIRED
None.
AVAILABILITY AND CONTACT POINT FOR INFORMATION ABOUT THIS TOOL
The ChameLAN 100 product famil y is available
commercially. For more information or a free demo,
call or write:
1.800.tek.elec
Tekelec
26580 West Agoura Road
Calabasas, CA 91302
Phone: 818.880.5656
Fax: 818.880.6993
The ChameLAN 100 is listed on the GSA schedule.
CONTACT POINT FOR CHANGES TO THIS CATALOG ENTRY
Todd Koch
Public Relations Specialist
818.880.7718
Internet: todd.koch@tekelec.com
NOCTools2 Working Group [Page 35]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog CMU_SNMP
NAME
The CMU SNMP Distribution
KEYWORDS
manager, status; IP; NMS, SNMP; UNIX; free, sourcelib.
ABSTRACT
The CMU SNMP Distribution includes source code for an
SNMP agent, several SNMP client applications, an ASN.1
library, and supporting documentation.
The agent compiles into about 10 KB of 68000 code. The
distribution includes a full agent that runs on a
Kinetics FastPath2/3/4, and is built into the KIP
appletalk/ethernet gateway. The machine independent
portions of this agent also run on CMU's IBM PC/AT
based router.
The applications are designed to be useful in the real
world. Information is collected and presented in a
useful format and is suitable for everyday status
monitoring. Input and output are interpreted
symbolically. The tools can be used without
referencing the RFCs.
MECHANISM
SNMP.
CAVEATS
None.
BUGS
None reported. Send bug reports to
sw0l+snmp@andrew.cmu.edu. ("sw0l" is "ess double-you
zero ell.")
LIMITATIONS
None reported.
HARDWARE REQUIRED
The KIP gateway agent runs on a Kinetics FastPath2/3/4.
Otherwise, no restrictions.
SOFTWARE REQUIRED
The code was written with efficiency and portability in
mind. The applications compile and run on the follow-
NOCTools2 Working Group [Page 36]
RFC 1470 FYI: Network Management Tool Catalog June 1993
ing systems: IBM PC/RT running ACIS Release 3, Sun3/50
running SUNOS 3.5, and the DEC microVax running Ultrix
2.2. They are expected to run on any system with a
Berkeley socket interface.
AVAILABILITY
This distribution is copyrighted by CMU, but may be
used and sold without permission. Consult the copy-
right notices for further information. The distribu-
tion is available by anonymous FTP from the host
lancaster.andrew.cmu.edu (128.2.13.21) as the files
pub/cmu-snmp.9.tar, and pub/kip-snmp.9.tar. The former
includes the libraries and the applications, and the
latter is the KIP SNMP agent.
Please direct questions, comments, and bug reports to
sw0l+snmp@andrew.cmu.edu. ("sw0l" is "ess double-you
zero ell.") If you pick up this package, please send a
note to the above address, so that you may be notified
of future enhancements/changes and additions to the set
of applications (several are planned).
NOCTools2 Working Group [Page 37]
RFC 1470 FYI: Network Management Tool Catalog June 1993
Internet Tool Catalog COMPUTER-SECURITY-CHECKLIST
NAME
Computer Security Checklist
KEYWORDS
security; DOS.
ABSTRACT
This program consists of 858 computer security ques-
tions divided up in thirteen sections. The program
presents the questions to the user and records their
responses. After answering the questions in one of the
thirteen sections, the user can generate a report from
the questions and the user's answers. The thirteen
sections are: telecommunications security, physical
access security, personnel security, systems develop-
ment security, security awareness and training prac-
tices, organizational and management security, data and
program security, processing and operations security,
ergonomics and error prevention, environmental secu-
rity, and backup and recovery security.
The questions are weighted as to their importance, and
the report generator can sort the questions by weight.
This way the most important issues can be tackled
first.
MECHANISM
The questions are displayed on the screen and the user
is prompted for a single keystroke reply. When the end
of one of the thirteen sections is reached, the answers
are written to a disk file. The question file and the
answer file are merged to create the report file.
CAVEATS
None.
BUGS
None known.
LIMITATIONS
None reported.
HARDWARE REQUIRED
No restrictions.
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?