📄 rfc1695.txt
字号:
SYNTAX INTEGER (0..4096)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of VPCs (PVCs and SVCs)
supported at this ATM interface. At the ATM UNI,
Ahmed & Tesink [Page 22]
RFC 1695 ATM Management Objects August 1994
the maximum number of VPCs (PVCs and SVCs)
ranges from 0 to 256 only."
::= { atmInterfaceConfEntry 1}
atmInterfaceMaxVccs OBJECT-TYPE
SYNTAX INTEGER (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of VCCs (PVCs and SVCs)
supported at this ATM interface."
::= { atmInterfaceConfEntry 2}
atmInterfaceConfVpcs OBJECT-TYPE
SYNTAX INTEGER (0..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of VPCs (PVCs and SVCs)
configured for use at this ATM interface.
At the ATM UNI, the configured number of
VPCs (PVCs and SVCs) can range from
0 to 256 only."
::= { atmInterfaceConfEntry 3}
atmInterfaceConfVccs OBJECT-TYPE
SYNTAX INTEGER (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of VCCs (PVCs and SVCs)
configured for use at the ATM interface."
::= { atmInterfaceConfEntry 4}
atmInterfaceMaxActiveVpiBits OBJECT-TYPE
SYNTAX INTEGER (0..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of active VPI bits
configured for use at the ATM interface.
At the ATM UNI, the maximum number of active
VPI bits configured for use ranges from
0 to 8 only."
::= { atmInterfaceConfEntry 5}
atmInterfaceMaxActiveVciBits OBJECT-TYPE
SYNTAX INTEGER (0..16)
Ahmed & Tesink [Page 23]
RFC 1695 ATM Management Objects August 1994
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of active VCI bits
configured for use at this ATM interface."
::= { atmInterfaceConfEntry 6}
atmInterfaceIlmiVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VPI value of the VCC supporting
the ILMI at this ATM interface. If the values of
atmInterfaceIlmiVpi and atmInterfaceIlmiVci are
both equal to zero then the ILMI is not
supported at this ATM interface."
DEFVAL { 0 }
::= { atmInterfaceConfEntry 7}
atmInterfaceIlmiVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VCI value of the VCC supporting
the ILMI at this ATM interface. If the values of
atmInterfaceIlmiVpi and atmInterfaceIlmiVci are
both equal to zero then the ILMI is not
supported at this ATM interface."
DEFVAL { 16 }
::= { atmInterfaceConfEntry 8}
atmInterfaceAddressType OBJECT-TYPE
SYNTAX INTEGER {
private(1),
nsapE164(2),
nativeE164(3),
other(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of primary ATM address configured
for use at this ATM interface."
::= { atmInterfaceConfEntry 9 }
atmInterfaceAdminAddress OBJECT-TYPE
Ahmed & Tesink [Page 24]
RFC 1695 ATM Management Objects August 1994
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An address assigned for administrative purposes,
for example, an address associated with the
service provider side of a public network UNI.
If this interface has no assigned administrative
address, or when the address used for
administrative purposes is the same as that used
for ifPhysAddress, then this is an octet string of
zero length."
::= { atmInterfaceConfEntry 10 }
atmInterfaceMyNeighborIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the neighbor system connected to
the far end of this interface, to which a Network
Management Station can send SNMP messages, as IP
datagrams sent to UDP port 161, in order to access
network management information concerning the
operation of that system. Note that the value
of this object may be obtained in different ways,
e.g., by manual configuration, or through ILMI
interaction with the neighbor system."
::= { atmInterfaceConfEntry 11 }
atmInterfaceMyNeighborIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The textual name of the interface on the neighbor
system on the far end of this interface, and to
which this interface connects. If the neighbor
system is manageable through SNMP and supports
the object ifName, the value of this object must
be identical with that of ifName for the ifEntry
of the lowest level physical interface
for this port. If this interface does not have a
textual name, the value of this object is a zero
length string. Note that the value of this object
may be obtained in different ways, e.g., by manual
configuration, or through ILMI interaction with
the neighbor system."
Ahmed & Tesink [Page 25]
RFC 1695 ATM Management Objects August 1994
::= { atmInterfaceConfEntry 12 }
-- The ATM Interface DS3 PLCP Group
-- This group contains the DS3 PLCP configuration and
-- state parameters of those ATM interfaces
-- which use DS3 PLCP for carrying ATM cells over DS3.
atmInterfaceDs3PlcpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmInterfaceDs3PlcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM interface DS3 PLCP
parameters and state variables, one entry per
ATM interface port."
::= { atmMIBObjects 3}
atmInterfaceDs3PlcpEntry OBJECT-TYPE
SYNTAX AtmInterfaceDs3PlcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains DS3 PLCP parameters and
state variables at the ATM interface."
INDEX {ifIndex }
::= { atmInterfaceDs3PlcpTable 1}
AtmInterfaceDs3PlcpEntry ::= SEQUENCE {
atmInterfaceDs3PlcpSEFSs Counter32,
atmInterfaceDs3PlcpAlarmState INTEGER,
atmInterfaceDs3PlcpUASs Counter32
}
atmInterfaceDs3PlcpSEFSs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DS3 PLCP Severely Errored Framing
Second (SEFS). Each SEFS represents a
one-second interval which contains
one or more SEF event."
::= { atmInterfaceDs3PlcpEntry 1}
atmInterfaceDs3PlcpAlarmState OBJECT-TYPE
Ahmed & Tesink [Page 26]
RFC 1695 ATM Management Objects August 1994
SYNTAX INTEGER {
noAlarm(1),
receivedFarEndAlarm(2),
incomingLOF(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if there is an
alarm present for the DS3 PLCP. The value
receivedFarEndAlarm means that the DS3 PLCP
has received an incoming Yellow
Signal, the value incomingLOF means that
the DS3 PLCP has declared a loss of frame (LOF)
failure condition, and the value noAlarm
means that there are no alarms present.
Transition from the failure to the no alarm state
occurs when no defects (e.g., LOF) are received
for more than 10 seconds."
::= { atmInterfaceDs3PlcpEntry 2}
atmInterfaceDs3PlcpUASs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds encountered by the PLCP."
::= { atmInterfaceDs3PlcpEntry 3}
-- The ATM Interface TC Sublayer Group
-- This group contains TC sublayer configuration and
-- state parameters of those ATM interfaces
-- which use TC sublayer for carrying ATM cells over
-- SONET or DS3.
atmInterfaceTCTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmInterfaceTCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM interface TC
Sublayer parameters and state variables,
one entry per ATM interface port."
::= { atmMIBObjects 4}
Ahmed & Tesink [Page 27]
RFC 1695 ATM Management Objects August 1994
atmInterfaceTCEntry OBJECT-TYPE
SYNTAX AtmInterfaceTCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains TC Sublayer parameters
and state variables at the ATM interface."