                      "The index number of the next appropriate
                      unassigned entry in the snmpAlarmTable.  The value
                      0 indicates that no unassigned entries are
                      available.

                      A management station should create new entries in
                      the snmpAlarmTable using this algorithm: first,
                      issue a management protocol retrieval operation to
                      determine the value of snmpAlarmNextIndex; and,
                      second, issue a management protocol set operation
                      to create an instance of the snmpAlarmStatus
                      object setting its value to `createAndGo' or
                      `createAndWait' (as specified in the description
                      of the RowStatus textual convention)."
              ::= { snmpAlarm 1 }

          snmpAlarmTable OBJECT-TYPE
              SYNTAX     SEQUENCE OF SnmpAlarmEntry
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                      "A list of snmpAlarm entries."
              ::= { snmpAlarm 2 }

          snmpAlarmEntry OBJECT-TYPE
              SYNTAX     SnmpAlarmEntry
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                      "A list of parameters that set up a periodic
                      sampling query to check for alarm conditions.  The
                      contextIdentity included in the INDEX clause is
                      the context to which the sampling queries are
                      directed."
              INDEX      { contextIdentity, snmpAlarmIndex }
              ::= { snmpAlarmTable 1 }









          Case, McCloghrie, Rose & Waldbusser                   [Page 8]





          RFC 1451            Manager-to-Manager MIB          April 1993


          SnmpAlarmEntry ::= SEQUENCE {
              snmpAlarmIndex                    INTEGER,
              snmpAlarmVariable                 InstancePointer,
              snmpAlarmInterval                 Integer32,
              snmpAlarmSampleType               INTEGER,
              snmpAlarmValue                    Integer32,
              snmpAlarmStartupAlarm             INTEGER,
              snmpAlarmRisingThreshold          Integer32,
              snmpAlarmFallingThreshold         Integer32,
              snmpAlarmRisingEventIndex         INTEGER,
              snmpAlarmFallingEventIndex        INTEGER,
              snmpAlarmUnavailableEventIndex    INTEGER,
              snmpAlarmStatus                   RowStatus
          }

          snmpAlarmIndex OBJECT-TYPE
              SYNTAX     INTEGER (1..65535)
              MAX-ACCESS not-accessible
              STATUS     current
              DESCRIPTION
                      "An index that uniquely identifies an entry in the
                      snmpAlarm table for a particular sampling context.
                      Each such entry defines a diagnostic sample at a
                      particular interval for a variable in the
                      particular context's object resources."
              ::= { snmpAlarmEntry 1 }
























          Case, McCloghrie, Rose & Waldbusser                   [Page 9]





          RFC 1451            Manager-to-Manager MIB          April 1993


          snmpAlarmVariable OBJECT-TYPE
              SYNTAX     InstancePointer
              MAX-ACCESS read-create
              STATUS     current
              DESCRIPTION
                      "The object identifier of the particular variable
                      to be sampled.  Only variables that resolve to an
                      ASN.1 primitive type of INTEGER (Integer32,
                      Counter32, Gauge32, TimeTicks, Counter64, or
                      UInteger32) may be sampled.

                      If it is detected by an error response of
                      authorizationError, noSuchObject, or
                      noSuchInstance that the variable name of an
                      established snmpAlarmEntry is no longer available
                      in the sampling context, a single
                      snmpObjectUnavailableAlarm event is generated and
                      the status of this snmpAlarmEntry is set to
                      `destroy'.  Likewise, if the syntax of the
                      variable retrieved by the query is not Integer32,
                      Counter32, Gauge32, TimeTicks, Counter64, or
                      UInteger32, the same actions will be taken.

                      If the SNMPv2 entity acting in a dual role detects
                      that the sampled value can not be obtained due to
                      lack of response to management queries, it should
                      either:

                           1) Set the status of this snmpAlarmEntry to
                           `destroy', if it is determined that further
                           communication is not possible;

                           or,

                           2) Delete the associated snmpAlarmValue
                           instance (but not the entire conceptual row),
                           and continue to attempt to sample the
                           variable and recreate the associated
                           snmpAlarmValue instance should communication
                           be reestablished.

                      An attempt to modify this object will fail with an
                      `inconsistentValue' error if the associated
                      snmpAlarmStatus object would be equal to `active'
                      both before and after the modification attempt."





          Case, McCloghrie, Rose & Waldbusser                  [Page 10]





          RFC 1451            Manager-to-Manager MIB          April 1993


              ::= { snmpAlarmEntry 2 }

          snmpAlarmInterval OBJECT-TYPE
              SYNTAX     Integer32
              UNITS      "seconds"
              MAX-ACCESS read-create
              STATUS     current
              DESCRIPTION
                      "The interval in seconds over which the data is
                      sampled and compared with the rising and falling
                      thresholds.  When setting this object and the
                      sampling type is `deltaValue',  care should be
                      taken to ensure that the change during this
                      interval of the variable being sampled will not
                      exceed the (-2^31...2^31-1) range of the
                      snmpAlarmValue.

                      An attempt to modify this object will fail with an
                      `inconsistentValue' error if the associated
                      snmpAlarmStatus object would be equal to `active'
                      both before and after the modification attempt."
              ::= { snmpAlarmEntry 3 }




























          Case, McCloghrie, Rose & Waldbusser                  [Page 11]





          RFC 1451            Manager-to-Manager MIB          April 1993


          snmpAlarmSampleType OBJECT-TYPE
              SYNTAX     INTEGER {
                             absoluteValue(1),
                             deltaValue(2)
                         }
              MAX-ACCESS read-create
              STATUS     current
              DESCRIPTION
                      "The method of sampling the selected variable and
                      calculating the value to be compared against the
                      thresholds.  If the value of this object is
                      `absoluteValue', the value of the selected
                      variable at the end of the sampling interval will
                      be compared directly with both the
                      snmpAlarmRisingThreshold and the
                      snmpAlarmFallingThreshold values.  If the value of
                      this object is `deltaValue', the value of the
                      selected variable at the end of the sampling
                      interval will be subtracted from its value at the
                      end of the previous sampling interval, and the
                      difference compared with both the
                      snmpAlarmRisingThreshold and the
                      snmpAlarmFallingThreshold values.

                      An attempt to modify this object will fail with an
                      `inconsistentValue' error if the associated
                      snmpAlarmStatus object would be equal to `active'
                      both before and after the modification attempt."
              DEFVAL { deltaValue }
              ::= { snmpAlarmEntry 4 }




















          Case, McCloghrie, Rose & Waldbusser                  [Page 12]





          RFC 1451            Manager-to-Manager MIB          April 1993


          snmpAlarmValue OBJECT-TYPE
              SYNTAX     Integer32
              MAX-ACCESS read-only
              STATUS     current
              DESCRIPTION
                      "The value of the statistic during the last
                      sampling period.  The value during the current
                      sampling period is not made available until the
                      period is completed.  If the value of the
                      statistic does not fit in the signed 32 bit
                      representation of this object, it should be
                      truncated in an implementation specific manner.

                      Note that if the associated snmpAlarmSampleType is
                      set to `deltaValue', the value of this object is
                      the difference in the sampled variable since the
                      last sample.

                      This object will be created by the SNMPv2 entity
                      acting in a dual role when this entry is set to
                      `active', and the first sampling period has
                      completed.  It may be created and deleted at other
                      times by the SNMPv2 entity acting in a dual role
                      when the sampled value can not be obtained, as
                      specified in the snmpAlarmVariable object."
              ::= { snmpAlarmEntry 5 }
























          Case, McCloghrie, Rose & Waldbusser                  [Page 13]





          RFC 1451            Manager-to-Manager MIB          April 1993


          snmpAlarmStartupAlarm OBJECT-TYPE
              SYNTAX     INTEGER {
                             risingAlarm(1),
                             fallingAlarm(2),
                             risingOrFallingAlarm(3)
                         }
              MAX-ACCESS read-create
              STATUS     current
              DESCRIPTION
                      "The alarm that may be sent when this entry is
                      first set to `active'.  If the first sample after
                      this entry becomes active is greater than or equal
                      to the risingThreshold and snmpAlarmStartupAlarm
                      is equal to `risingAlarm' or
                      `risingOrFallingAlarm', then a single rising alarm
                      will be generated.  If the first sample after this
                      entry becomes active is less than or equal to the
                      fallingThreshold and snmpAlarmStartupAlarm is
                      equal to `fallingAlarm' or `risingOrFallingAlarm',
                      then a single falling alarm will be generated.
                      Note that a snmpObjectUnavailableAlarm is sent
                      upon startup whenever it is applicable,
                      independent of the setting of
                      snmpAlarmStartupAlarm.

                      An attempt to modify this object will fail with an
                      `inconsistentValue' error if the associated
                      snmpAlarmStatus object would be equal to `active'
                      both before and after the modification attempt."
              DEFVAL { risingOrFallingAlarm }
              ::= { snmpAlarmEntry 6 }



















          Case, McCloghrie, Rose & Waldbusser                  [Page 14]





          RFC 1451            Manager-to-Manager MIB          April 1993


          snmpAlarmRisingThreshold OBJECT-TYPE
              SYNTAX     Integer32
              MAX-ACCESS read-create
              STATUS     current
              DESCRIPTION
                      "A threshold for the sampled statistic.  When the
                      current sampled value is greater than or equal to
                      this threshold, and the value at the last sampling
                      interval was less than this threshold, a single
                      event will be generated.  A single event will also
                      be generated if the first sample after this entry
                      becomes active is greater than or equal to this
                      threshold and the associated snmpAlarmStartupAlarm
                      is equal to `risingAlarm' or
                      `risingOrFallingAlarm'.

                      After a rising event is generated, another such