rfc1316.txt
来自「RFC 的详细文档!」· 文本 代码 · 共 955 行 · 第 1/3 页
TXT
955 行
ranges between 1 and the value of charNumber. By
convention and if possible, hardware port numbers
come first, with a simple, direct mapping. The
value for each port must remain constant at least
from one re-initialization of the network management
agent to the next."
::= { charPortEntry 1 }
charPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An administratively assigned name for the port,
typically with some local significance."
Character MIB Working Group [Page 6]
RFC 1316 Character MIB April 1992
::= { charPortEntry 2 }
charPortType OBJECT-TYPE
SYNTAX INTEGER { physical(1), virtual(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's type, 'physical' if the port represents
an external hardware connector, 'virtual' if it does
not."
::= { charPortEntry 3 }
charPortHardware OBJECT-TYPE
SYNTAX AutonomousType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A reference to hardware MIB definitions specific to
a physical port's external connector. For example,
if the connector is RS-232, then the value of this
object refers to a MIB sub-tree defining objects
specific to RS-232. If an agent is not configured
to have such values, the agent returns the object
identifier:
nullHardware OBJECT IDENTIFIER ::= { 0 0 }
"
::= { charPortEntry 4 }
charPortReset OBJECT-TYPE
SYNTAX INTEGER { ready(1), execute(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A control to force the port into a clean, initial
state, both hardware and software, disconnecting all
the port's existing sessions. In response to a
get-request or get-next-request, the agent always
returns 'ready' as the value. Setting the value to
'execute' causes a reset."
::= { charPortEntry 5 }
charPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2), off(3),
maintenance(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
Character MIB Working Group [Page 7]
RFC 1316 Character MIB April 1992
"The port's desired state, independent of flow
control. 'enabled' indicates that the port is
allowed to pass characters and form new sessions.
'disabled' indicates that the port is allowed to
pass characters but not form new sessions. 'off'
indicates that the port is not allowed to pass
characters or have any sessions. 'maintenance'
indicates a maintenance mode, exclusive of normal
operation, such as running a test."
::= { charPortEntry 6 }
charPortOperStatus OBJECT-TYPE
SYNTAX INTEGER { up(1), down(2),
maintenance(3), absent(4), active(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's actual, operational state, independent
of flow control. 'up' indicates able to function
normally. 'down' indicates inability to function
for administrative or operational reasons.
'maintenance' indicates a maintenance mode,
exclusive of normal operation, such as running a
test. 'absent' indicates that port hardware is not
present. 'active' indicates up with a user present
(e.g. logged in)."
::= { charPortEntry 7 }
charPortLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the port entered
its current operational state. If the current state
was entered prior to the last reinitialization of
the local network management subsystem, then this
object contains a zero value."
::= { charPortEntry 8 }
charPortInFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), xonXoff(2), hardware(3),
ctsRts(4), dsrDtr(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port's type of input flow control. 'none'
indicates no flow control at this level or below.
Character MIB Working Group [Page 8]
RFC 1316 Character MIB April 1992
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicity's sake."
::= { charPortEntry 9 }
charPortOutFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), xonXoff(2), hardware(3),
ctsRts(4), dsrDtr(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port's type of output flow control. 'none'
indicates no flow control at this level or below.
'xonXoff' indicates software flow control by
recognizing XON and XOFF characters. 'hardware'
indicates flow control delegated to the lower level,
for example a parallel port.
'ctsRts' and 'dsrDtr' are specific to RS-232-like
ports. Although not architecturally pure, they are
included here for simplicy's sake."
::= { charPortEntry 10 }
charPortInFlowState OBJECT-TYPE
SYNTAX INTEGER { none(1), unknown(2), stop(3), go(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational state of input flow control
on the port. 'none' indicates not applicable.
'unknown' indicates this level does not know.
'stop' indicates flow not allowed. 'go' indicates
flow allowed."
::= { charPortEntry 11 }
charPortOutFlowState OBJECT-TYPE
SYNTAX INTEGER { none(1), unknown(2), stop(3), go(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational state of output flow
control on the port. 'none' indicates not
applicable. 'unknown' indicates this level does not
Character MIB Working Group [Page 9]
RFC 1316 Character MIB April 1992
know. 'stop' indicates flow not allowed. 'go'
indicates flow allowed."
::= { charPortEntry 12 }
charPortInCharacters OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of characters detected as input from
the port since system re-initialization and while
the port operational state was 'up', 'active', or
'maintenance', including, for example, framing, flow
control (i.e. XON and XOFF), each occurrence of a
BREAK condition, locally-processed input, and input
sent to all sessions."
::= { charPortEntry 13 }
charPortOutCharacters OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of characters detected as output to
the port since system re-initialization and while
the port operational state was 'up', 'active', or
'maintenance', including, for example, framing, flow
control (i.e. XON and XOFF), each occurrence of a
BREAK condition, locally-created output, and output
received from all sessions."
::= { charPortEntry 14 }
charPortAdminOrigin OBJECT-TYPE
SYNTAX INTEGER { dynamic(1), network(2), local(3),
none(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The administratively allowed origin for
establishing session on the port. 'dynamic' allows
'network' or 'local' session establishment. 'none'
disallows session establishment."
::= { charPortEntry 15 }
charPortSessionMaximum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
Character MIB Working Group [Page 10]
RFC 1316 Character MIB April 1992
DESCRIPTION
"The maximum number of concurrent sessions allowed
on the port. A value of -1 indicates no maximum.
Setting the maximum to less than the current number
of sessions has unspecified results."
::= { charPortEntry 16 }
charPortSessionNumber OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of open sessions on the port that are in
the connecting, connected, or disconnecting state."
::= { charPortEntry 17 }
charPortSessionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of charSessIndex for the port's first or
only active session. If the port has no active
session, the agent returns the value zero."
::= { charPortEntry 18 }
-- the Character Session table
charSessTable OBJECT-TYPE
SYNTAX SEQUENCE OF CharSessEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port session entries."
::= { char 3 }
charSessEntry OBJECT-TYPE
SYNTAX CharSessEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status and parameter values for a character port
session."
INDEX { charSessPortIndex, charSessIndex }
::= { charSessTable 1 }
Character MIB Working Group [Page 11]
RFC 1316 Character MIB April 1992
CharSessEntry ::=
SEQUENCE {
charSessPortIndex
INTEGER,
charSessIndex
INTEGER,
charSessKill
INTEGER,
charSessState
INTEGER,
charSessProtocol
AutonomousType,
charSessOperOrigin
INTEGER,
charSessInCharacters
Counter,