A similar type of classifier can be defined for IPv6.
4.2.3. Free-form Classifier
A Free-form classifier is made up of a set of user definable
arbitrary filters each made up of {bit-field size, offset (from head
of packet), mask}:
Classifier2:
Filter12: OutputA
Filter13: OutputB
Default: OutputC
Bernet, et. al. Informational [Page 17]
RFC 3290 Diffserv Informal Management Model May 2002
Filter12:
Type: FreeForm
SizeBits: 3 (bits)
Offset: 16 (bytes)
Value: 100 (binary)
Mask: 101 (binary)
Filter13:
Type: FreeForm
SizeBits: 12 (bits)
Offset: 16 (bytes)
Value: 100100000000 (binary)
Mask: 111111111111 (binary)
Free-form filters can be combined into filter groups to form very
powerful filters.
4.2.4. Other Possible Classifiers
Classification may also be performed based on information at the
datalink layer below IP (e.g., VLAN or datalink-layer priority) or
perhaps on the ingress or egress IP, logical or physical interface
identifier (e.g., the incoming channel number on a channelized
interface). A classifier that filters based on IEEE 802.1p Priority
and on 802.1Q VLAN-ID might be represented as:
Classifier3:
Filter14 AND Filter15: OutputA
Default: OutputB
Filter14: -- priority 4 or 5
Type: Ieee8021pPriority
Value: 100 (binary)
Mask: 110 (binary)
Filter15: -- VLAN 2304
Type: Ieee8021QVlan
Value: 100100000000 (binary)
Mask: 111111111111 (binary)
Such classifiers may be the subject of other standards or may be
proprietary to a router vendor but they are not discussed further
here.
Bernet, et. al. Informational [Page 18]
RFC 3290 Diffserv Informal Management Model May 2002
5. Meters
Metering is defined in [DSARCH]. Diffserv network providers may
choose to offer services to customers based on a temporal (i.e.,
rate) profile within which the customer submits traffic for the
service. In this event, a meter might be used to trigger real-time
traffic conditioning actions (e.g., marking) by routing a non-
conforming packet through an appropriate next-stage action element.
Alternatively, by counting conforming and/or non-conforming traffic
using a Counter element downstream of the Meter, it might also be
used to help in collecting data for out-of-band management functions
such as billing applications.
Meters are logically 1:N (fan-out) devices (although a multiplexor
can be used in front of a meter). Meters are parameterized by a
temporal profile and by conformance levels, each of which is
associated with a meter's output. Each output can be connected to
another functional element.
Note that this model of a meter differs slightly from that described
in [DSARCH]. In that description the meter is not a datapath element
but is instead used to monitor the traffic stream and send control
signals to action elements to dynamically modulate their behavior
based on the conformance of the packet. This difference in the
description does not change the function of a meter. Figure 4
illustrates a meter with 3 levels of conformance.
In some Diffserv examples (e.g., [AF-PHB]), three levels of
conformance are discussed in terms of colors, with green representing
conforming, yellow representing partially conforming and red
representing non-conforming. These different conformance levels may
be used to trigger different queuing, marking or dropping treatment
later on in the processing. Other example meters use a binary notion
of conformance; in the general case N levels of conformance can be
supported. In general there is no constraint on the type of
functional datapath element following a meter output, but care must
be taken not to inadvertently configure a datapath that results in
packet reordering that is not consistent with the requirements of the
relevant PHB specification.
Bernet, et. al. Informational [Page 19]
RFC 3290 Diffserv Informal Management Model May 2002
unmetered metered
traffic traffic
+---------+
| |--------> conformance A
--------->| meter |--------> conformance B
| |--------> conformance C
+---------+
Figure 4. A Generic Meter
A meter, according to this model, measures the rate at which packets
making up a stream of traffic pass it, compares the rate to some set
of thresholds, and produces some number of potential results (two or
more): a given packet is said to be "conformant" to a level of the
meter if, at the time that the packet is being examined, the stream
appears to be within the rate limit for the profile associated with
that level. A fuller discussion of conformance to meter profiles
(and the associated requirements that this places on the schedulers
upstream) is provided in Appendix A.
5.1. Examples
The following are some examples of possible meters.
5.1.1. Average Rate Meter
An example of a very simple meter is an average rate meter. This
type of meter measures the average rate at which packets are
submitted to it over a specified averaging time.
An average rate profile may take the following form:
Meter1:
Type: AverageRate
Profile: Profile1
ConformingOutput: Queue1
NonConformingOutput: Counter1
Profile1:
Type: AverageRate
AverageRate: 120 kbps
Delta: 100 msec
A Meter measuring against this profile would continually maintain a
count that indicates the total number and/or cumulative byte-count of
packets arriving between time T (now) and time T - 100 msecs. So
long as an arriving packet does not push the count over 12 kbits in
the last 100 msec, the packet would be deemed conforming. Any packet
Bernet, et. al. Informational [Page 20]
RFC 3290 Diffserv Informal Management Model May 2002
that pushes the count over 12 kbits would be deemed non-conforming.
Thus, this Meter deems packets to correspond to one of two
conformance levels: conforming or non-conforming, and sends them on
for the appropriate subsequent treatment.
5.1.2. Exponential Weighted Moving Average (EWMA) Meter
The EWMA form of Meter is easy to implement in hardware and can be
parameterized as follows:
avg_rate(t) = (1 - Gain) * avg_rate(t') + Gain * rate(t)
t = t' + Delta
For a packet arriving at time t:
if (avg_rate(t) > AverageRate)
non-conforming
else
conforming
"Gain" controls the time constant (e.g., frequency response) of what
is essentially a simple IIR low-pass filter. "Rate(t)" measures the
number of incoming bytes in a small fixed sampling interval, Delta.
Any packet that arrives and pushes the average rate over a predefined
rate AverageRate is deemed non-conforming. An EWMA Meter profile
might look something like the following:
Meter2:
Type: ExpWeightedMovingAvg
Profile: Profile2
ConformingOutput: Queue1
NonConformingOutput: AbsoluteDropper1
Profile2:
Type: ExpWeightedMovingAvg
AverageRate: 25 kbps
Delta: 10 usec
Gain: 1/16
5.1.3. Two-Parameter Token Bucket Meter
A more sophisticated Meter might measure conformance to a token
bucket (TB) profile. A TB profile generally has two parameters, an
average token rate, R, and a burst size, B. TB Meters compare the
arrival rate of packets to the average rate specified by the TB
profile. Logically, tokens accumulate in a bucket at the average
Bernet, et. al. Informational [Page 21]
RFC 3290 Diffserv Informal Management Model May 2002
rate, R, up to a maximum credit which is the burst size, B. When a
packet of length L arrives, a conformance test is applied. There are
at least two such tests in widespread use:
Strict conformance
Packets of length L bytes are considered conforming only if there
are sufficient tokens available in the bucket at the time of
packet arrival for the complete packet (i.e., the current depth is
greater than or equal to L): no tokens may be borrowed from future
token allocations. For examples of this approach, see [SRTCM] and
[TRTCM].
Loose conformance
Packets of length L bytes are considered conforming if any tokens
are available in the bucket at the time of packet arrival: up to L
bytes may then be borrowed from future token allocations.
Packets are allowed to exceed the average rate in bursts up to the
burst size. For further discussion of loose and strict conformance
to token bucket profiles, as well as system and implementation
issues, see Appendix A.
A two-parameter TB meter has exactly two possible conformance levels
(conforming, non-conforming). Such a meter might appear as follows:
Meter3:
Type: SimpleTokenBucket
Profile: Profile3
ConformanceType: loose
ConformingOutput: Queue1
NonConformingOutput: AbsoluteDropper1
Profile3:
Type: SimpleTokenBucket
AverageRate: 200 kbps
BurstSize: 100 kbytes
5.1.4. Multi-Stage Token Bucket Meter
More complicated TB meters might define multiple burst sizes and more
conformance levels. Packets found to exceed the larger burst size
are deemed non-conforming. Packets found to exceed the smaller burst
size are deemed partially-conforming. Packets exceeding neither are
deemed conforming. Some token bucket meters designed for Diffserv
networks are described in more detail in [SRTCM, TRTCM]; in some of
these references, three levels of conformance are discussed in terms
of colors with green representing conforming, yellow representing
partially conforming, and red representing non-conforming. Note that
Bernet, et. al. Informational [Page 22]
RFC 3290 Diffserv Informal Management Model May 2002
these multiple-conformance-level meters can sometimes be implemented
using an appropriate sequence of multiple two-parameter TB meters.
A profile for a multi-stage TB meter with three levels of conformance
might look as follows: