📄 rfc1514.txt
字号:
"The product ID of the firmware associated with the
processor."
::= { hrProcessorEntry 1 }
hrProcessorLoad OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The average, over the last minute, of the
percentage of time that this processor was not
idle."
::= { hrProcessorEntry 2 }
hrNetworkTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrNetworkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table of network devices
contained by the host.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDeviceNetwork'."
::= { hrDevice 4 }
hrNetworkEntry OBJECT-TYPE
SYNTAX HrNetworkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A (conceptual) entry for one network device
contained by the host. The hrDeviceIndex in the
index represents the entry in the hrDeviceTable
that corresponds to the hrNetworkEntry.
As an example of how objects in this table are
named, an instance of the hrNetworkIfIndex object
might be named hrNetworkIfIndex.3"
INDEX { hrDeviceIndex }
::= { hrNetworkTable 1 }
Grillo & Waldbusser [Page 14]
RFC 1514 Host Resources MIB September 1993
HrNetworkEntry ::= SEQUENCE {
hrNetworkIfIndex INTEGER
}
hrNetworkIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of ifIndex which corresponds to this
network device."
::= { hrNetworkEntry 1 }
hrPrinterTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrPrinterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table of printers local to the
host.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDevicePrinter'."
::= { hrDevice 5 }
hrPrinterEntry OBJECT-TYPE
SYNTAX HrPrinterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A (conceptual) entry for one printer local to the
host. The hrDeviceIndex in the index represents
the entry in the hrDeviceTable that corresponds to
the hrPrinterEntry.
As an example of how objects in this table are
named, an instance of the hrPrinterStatus object
might be named hrPrinterStatus.3"
INDEX { hrDeviceIndex }
::= { hrPrinterTable 1 }
HrPrinterEntry ::= SEQUENCE {
hrPrinterStatus INTEGER,
hrPrinterDetectedErrorState OCTET STRING
}
Grillo & Waldbusser [Page 15]
RFC 1514 Host Resources MIB September 1993
hrPrinterStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
idle(3),
printing(4),
warmup(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of this printer device. When
in the idle(1), printing(2), or warmup(3) state,
the corresponding hrDeviceStatus should be
running(2) or warning(3). When in the unknown
state, the corresponding hrDeviceStatus should be
unknown(1)."
::= { hrPrinterEntry 1 }
hrPrinterDetectedErrorState OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents any error conditions
detected by the printer. The error conditions are
encoded as bits in an octet string, with the
following definitions:
Condition Bit # hrDeviceStatus
lowPaper 0 warning(3)
noPaper 1 down(5)
lowToner 2 warning(3)
noToner 3 down(5)
doorOpen 4 down(5)
jammed 5 down(5)
offline 6 down(5)
serviceRequested 7 warning(3)
If multiple conditions are currently detected and
the hrDeviceStatus would not otherwise be
unknown(1) or testing(4), the hrDeviceStatus shall
correspond to the worst state of those indicated,
where down(5) is worse than warning(3) which is
worse than running(2).
Bits are numbered starting with the most
Grillo & Waldbusser [Page 16]
RFC 1514 Host Resources MIB September 1993
significant bit of the first byte being bit 0, the
least significant bit of the first byte being bit
7, the most significant bit of the second byte
being bit 8, and so on. A one bit encodes that
the condition was detected, while a zero bit
encodes that the condition was not detected.
This object is useful for alerting an operator to
specific warning or error conditions that may
occur, especially those requiring human
intervention."
::= { hrPrinterEntry 2 }
hrDiskStorageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrDiskStorageEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table of long-term storage
devices contained by the host. In particular, disk
devices accessed remotely over a network are not
included here.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDeviceDiskStorage'."
::= { hrDevice 6 }
hrDiskStorageEntry OBJECT-TYPE
SYNTAX HrDiskStorageEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A (conceptual) entry for one long-term storage
device contained by the host. The hrDeviceIndex in
the index represents the entry in the hrDeviceTable
that corresponds to the hrDiskStorageEntry. As an
example, an instance of the hrDiskStorageCapacity
object might be named hrDiskStorageCapacity.3"
INDEX { hrDeviceIndex }
::= { hrDiskStorageTable 1 }
HrDiskStorageEntry ::= SEQUENCE {
hrDiskStorageAccess INTEGER,
hrDiskStorageMedia INTEGER,
hrDiskStorageRemoveble Boolean,
hrDiskStorageCapacity KBytes
Grillo & Waldbusser [Page 17]
RFC 1514 Host Resources MIB September 1993
}
hrDiskStorageAccess OBJECT-TYPE
SYNTAX INTEGER {
readWrite(1),
readOnly(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication if this long-term storage device is
readable and writable or only readable. This
should reflect the media type, any write-protect
mechanism, and any device configuration that
affects the entire device."
::= { hrDiskStorageEntry 1 }
hrDiskStorageMedia OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
hardDisk(3),
floppyDisk(4),
opticalDiskROM(5),
opticalDiskWORM(6), -- Write Once Read Many
opticalDiskRW(7),
ramDisk(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of the type of media used in this
long-term storage device."
::= { hrDiskStorageEntry 2 }
hrDiskStorageRemoveble OBJECT-TYPE
SYNTAX Boolean
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes whether or not the disk media may be
removed from the drive."
::= { hrDiskStorageEntry 3 }
hrDiskStorageCapacity OBJECT-TYPE
SYNTAX KBytes
ACCESS read-only
STATUS mandatory
Grillo & Waldbusser [Page 18]
RFC 1514 Host Resources MIB September 1993
DESCRIPTION
"The total size for this long-term storage device."
::= { hrDiskStorageEntry 4 }
hrPartitionTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrPartitionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table of partitions for long-term
storage devices contained by the host. In
particular, partitions accessed remotely over a
network are not included here."
::= { hrDevice 7 }
hrPartitionEntry OBJECT-TYPE
SYNTAX HrPartitionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A (conceptual) entry for one partition. The
hrDeviceIndex in the index represents the entry in
the hrDeviceTable that corresponds to the
hrPartitionEntry.
As an example of how objects in this table are
named, an instance of the hrPartitionSize object
might be named hrPartitionSize.3.1"
INDEX { hrDeviceIndex, hrPartitionIndex }
::= { hrPartitionTable 1 }
HrPartitionEntry ::= SEQUENCE {
hrPartitionIndex INTEGER,
hrPartitionLabel InternationalDisplayString,
hrPartitionID OCTET STRING,
hrPartitionSize KBytes,
hrPartitionFSIndex INTEGER
}
hrPartitionIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each partition on this long-
term storage device. The value for each long-term
storage device must remain constant at least from
one re-initialization of the agent to the next re-
Grillo & Waldbusser [Page 19]
RFC 1514 Host Resources MIB September 1993
initialization."
::= { hrPartitionEntry 1 }
hrPartitionLabel OBJECT-TYPE
SYNTAX InternationalDisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of this partition."
::= { hrPartitionEntry 2 }
hrPartitionID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A descriptor which uniquely represents this
partition to the responsible operating system. On
some systems, this might take on a binary
representation."
::= { hrPartitionEntry 3 }
hrPartitionSize OBJECT-TYPE
SYNTAX KBytes
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of this partition."
::= { hrPartitionEntry 4 }
hrPartitionFSIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the file system mounted on this
partition. If no file system is mounted on this
⌨️ 快捷键说明