              SYNTAX  INTEGER {
                          noAlarm (1),
                          receivedFarEndAlarm (2),
                          incomingLOF (3)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "This variable indicates if there is an alarm
                      present for the DS1 PLCP.  The value
                      receivedFarEndAlarm means that the DS1 PLCP has
                      received an incoming Yellow Signal, the value
                      incomingLOF means that the DS1 PLCP has declared a
                      loss of frame (LOF) failure condition, and the
                      value noAlarm means that there are no alarms
                      present.  See TR-TSV-000773 for a description of
                      alarm states."
              ::= { sipDS1PLCPEntry 3 }


          sipDS1PLCPUASs OBJECT-TYPE
              SYNTAX  Counter
              ACCESS  read-only
              STATUS  mandatory



SNMP Working Group                                             [Page 13]

RFC 1304                      SIP Objects                  February 1992


              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, as defined by TR-TSV-000773,
                      encountered by the PLCP."
              ::= { sipDS1PLCPEntry 4 }


          -- The SIP DS3 PLCP group
          -- Implementation of this group is mandatory
          -- if the DS3 PLCP is implemented.

          sipDS3PLCPTable  OBJECT-TYPE
              SYNTAX  SEQUENCE OF SipDS3PLCPEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "This table contains SIP DS3 PLCP parameters and
                      state variables, one entry per SIP port."
              ::= { sipPLCP 2 }

          sipDS3PLCPEntry  OBJECT-TYPE
              SYNTAX  SipDS3PLCPEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "This list contains SIP DS3 PLCP parameters and
                      state variables."
              INDEX   { sipDS3PLCPIndex }
              ::= { sipDS3PLCPTable 1 }

          SipDS3PLCPEntry  ::= SEQUENCE {
              sipDS3PLCPIndex
                  INTEGER,
              sipDS3PLCPSEFSs
                  Counter,
              sipDS3PLCPAlarmState
                  INTEGER,
              sipDS3PLCPUASs
                  Counter
              }


          sipDS3PLCPIndex  OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The value of this object identifies the SIP port



SNMP Working Group                                             [Page 14]

RFC 1304                      SIP Objects                  February 1992


                      interface for which this entry contains management
                      information.  The value of this object for a
                      particular interface has the same value as the
                      ifIndex object, defined in RFC 1156 and RFC 1213,
                      for the same interface."
              ::= { sipDS3PLCPEntry 1 }

          sipDS3PLCPSEFSs OBJECT-TYPE
              SYNTAX  Counter
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A DS3 Severely Errored Framing Second (SEFS) is a
                      count of one-second intervals containing one or
                      more SEF events.  A Severely Errored Framing (SEF)
                      event is declared when an error in the A1 octet
                      and an error in the A2 octet of a framing octet
                      pair (i.e., errors in both framing octets), or two
                      consecutive invalid and/or nonsequential Path
                      Overhead Identifier octets are detected."
              ::= { sipDS3PLCPEntry 2 }

          sipDS3PLCPAlarmState OBJECT-TYPE
              SYNTAX  INTEGER {
                          noAlarm (1),
                          receivedFarEndAlarm (2),
                          incomingLOF (3)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "This variable indicates if there is an alarm
                      present for the DS3 PLCP.  The value
                      receivedFarEndAlarm means that the DS3 PLCP has
                      received an incoming Yellow Signal, the value
                      incomingLOF means that the DS3 PLCP has declared a
                      loss of frame (LOF) failure condition, and the
                      value noAlarm means that there are no alarms
                      present.  See TR-TSV-000773 for a description of
                      alarm states."
              ::= { sipDS3PLCPEntry 3 }


          sipDS3PLCPUASs OBJECT-TYPE
              SYNTAX  Counter
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION



SNMP Working Group                                             [Page 15]

RFC 1304                      SIP Objects                  February 1992


                      "The counter associated with the number of
                      Unavailable Seconds, as defined by TR-TSV-000773,
                      encountered by the PLCP."
              ::= { sipDS3PLCPEntry 4 }


          -- The SMDS Applications group
          -- Applications that have been identified for this group are:
          --          * IP-over-SMDS (details are specified in RFC 1209)
          -- Implementation of this group is mandatory for systems
          -- that implement IP-over-SMDS Interface Protocol.

          smdsApplications OBJECT IDENTIFIER ::= { sip 4 }

          ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }

          -- Although the objects in this group are read-only, at the
          -- agent's discretion they may be made read-write so that the
          -- management station, when appropriately authorized, may
          -- change the addressing information related to the
          -- configuration of a logical IP subnetwork implemented on
          -- top of SMDS.

          -- This table is necessary to support RFC1209 (IP-over-SMDS)
          -- and gives information on the Group Addresses and ARP
          -- Addresses used in the Logical IP subnetwork.
          -- One SMDS address may be associated with multiple IP
          -- addresses.  One SNI may be associated with multiple LISs.

          ipOverSMDSTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF IpOverSMDSEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The table of addressing information relevant to
                      this entity's IP addresses."
              ::= { ipOverSMDS 1 }

          ipOverSMDSEntry OBJECT-TYPE
              SYNTAX  IpOverSMDSEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The addressing information for one of this
                      entity's IP addresses."
              INDEX   { ipOverSMDSIndex, ipOverSMDSAddress }
              ::= { ipOverSMDSTable 1 }




SNMP Working Group                                             [Page 16]

RFC 1304                      SIP Objects                  February 1992


          IpOverSMDSEntry ::=
              SEQUENCE {
                 ipOverSMDSIndex
                     INTEGER,
                 ipOverSMDSAddress
                     IpAddress,
                 ipOverSMDSHA
                     SMDSAddress,
                 ipOverSMDSLISGA
                     SMDSAddress,
                 ipOverSMDSARPReq
                     SMDSAddress
                 }

          ipOverSMDSIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The value of this object identifies the SIP port
                      interface for which this entry contains management
                      information.  The value of this object for a
                      particular interface has the same value as the
                      ifIndex object, defined in RFC 1156 and RFC 1213,
                      for the same interface."
              ::= { ipOverSMDSEntry 1 }

          ipOverSMDSAddress OBJECT-TYPE
               SYNTAX  IpAddress
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                      "The IP address to which this entry's addressing
                      information pertains."
              ::= { ipOverSMDSEntry 2 }

          ipOverSMDSHA OBJECT-TYPE
              SYNTAX  SMDSAddress
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The SMDS Individual address of the IP station."
              ::= { ipOverSMDSEntry 3 }

          ipOverSMDSLISGA OBJECT-TYPE
              SYNTAX  SMDSAddress
              ACCESS  read-only
              STATUS  mandatory



SNMP Working Group                                             [Page 17]

RFC 1304                      SIP Objects                  February 1992


              DESCRIPTION
                      "The SMDS Group Address that has been configured
                      to identify the SMDS Subscriber-Network Interfaces
                      (SNIs) of all members of the Logical IP Subnetwork
                      (LIS) connected to the network supporting SMDS."
              ::= { ipOverSMDSEntry 4 }

          ipOverSMDSARPReq OBJECT-TYPE
              SYNTAX  SMDSAddress
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The SMDS address (individual or group) to which
                      ARP Requests are to be sent."
              ::= { ipOverSMDSEntry 5 }


          -- The SMDS Carrier Selection group
          -- This group is used as a place holder
          -- for carrier selection objects.

          smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}


          -- The SIP Error Log
          -- Implementation of this group is mandatory
          -- for all systems that implement SIP Level 3.

          sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }

          sipL3PDUErrorTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF SipL3PDUErrorEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A table that contains the latest occurrence of
                      the following syntactical SIP L3PDU errors:

                      - Destination Address Field Format Error,

                      The following pertains to the 60 least significant
                      bits of the 64 bit address field.  The 60 bits
                      contained in the address subfield can be used to
                      represent addresses up to 15 decimal digits.  Each
                      decimal digit shall be encoded into four bits
                      using Binary Coded Decimal (BCD), with the most
                      significant digit occurring left-most.  If not all
                      15 digits are required, then the remainder of this



SNMP Working Group                                             [Page 18]

RFC 1304                      SIP Objects                  February 1992


                      field shall be padded on the right with bits set
                      to one.  An error is considered to have occurred:
                      a).  if the first four bits of the address
                      subfield are not BCD, OR b).  if the first four
                      bits of the address subfield are populated with
                      the country code value 0001, AND the 40 bits which
                      follow are not Binary Coded Decimal (BCD) encoded
                      values of the 10 digit addresses, OR the remaining
                      16 least significant bits are not populated with
                      1's, OR c).  if the address subfield is not
                      correct according to another numbering plan which
                      is dependent upon the carrier assigning the
                      numbers and offering SMDS.

                      - Source Address Field Format Error,

                      The description of this parameter is the same as
                      the description of the Destination Address Field
                      Format Error.

                      - Invalid BAsize Field Value,

                      An error is considered to have occurred when the
                      BAsize field of an SIP L3PDU contains a value less
                      that 32, greater than 9220 octets without the
                      CRC32 field present, greater than 9224 octets with
                      the CRC32 field present, or not equal to a
                      multiple of 4 octets,

                      - Invalid Header Extension Length Field Value,

                      An error is considered to have occurred when the
                      Header Extension Length field value is not equal
                      3.

                      - Invalid Header Extension - Element Length,

                      An error is considered to have occurred when the
                      Header Extension - Element Length is greater than

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -