📄 rfc1304.txt
字号:
SYNTAX INTEGER {
noAlarm (1),
receivedFarEndAlarm (2),
incomingLOF (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates if there is an alarm
present for the DS1 PLCP. The value
receivedFarEndAlarm means that the DS1 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS1 PLCP has declared a
loss of frame (LOF) failure condition, and the
value noAlarm means that there are no alarms
present. See TR-TSV-000773 for a description of
alarm states."
::= { sipDS1PLCPEntry 3 }
sipDS1PLCPUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
SNMP Working Group [Page 13]
RFC 1304 SIP Objects February 1992
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP."
::= { sipDS1PLCPEntry 4 }
-- The SIP DS3 PLCP group
-- Implementation of this group is mandatory
-- if the DS3 PLCP is implemented.
sipDS3PLCPTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipDS3PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains SIP DS3 PLCP parameters and
state variables, one entry per SIP port."
::= { sipPLCP 2 }
sipDS3PLCPEntry OBJECT-TYPE
SYNTAX SipDS3PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This list contains SIP DS3 PLCP parameters and
state variables."
INDEX { sipDS3PLCPIndex }
::= { sipDS3PLCPTable 1 }
SipDS3PLCPEntry ::= SEQUENCE {
sipDS3PLCPIndex
INTEGER,
sipDS3PLCPSEFSs
Counter,
sipDS3PLCPAlarmState
INTEGER,
sipDS3PLCPUASs
Counter
}
sipDS3PLCPIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
SNMP Working Group [Page 14]
RFC 1304 SIP Objects February 1992
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { sipDS3PLCPEntry 1 }
sipDS3PLCPSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A DS3 Severely Errored Framing Second (SEFS) is a
count of one-second intervals containing one or
more SEF events. A Severely Errored Framing (SEF)
event is declared when an error in the A1 octet
and an error in the A2 octet of a framing octet
pair (i.e., errors in both framing octets), or two
consecutive invalid and/or nonsequential Path
Overhead Identifier octets are detected."
::= { sipDS3PLCPEntry 2 }
sipDS3PLCPAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noAlarm (1),
receivedFarEndAlarm (2),
incomingLOF (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates if there is an alarm
present for the DS3 PLCP. The value
receivedFarEndAlarm means that the DS3 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS3 PLCP has declared a
loss of frame (LOF) failure condition, and the
value noAlarm means that there are no alarms
present. See TR-TSV-000773 for a description of
alarm states."
::= { sipDS3PLCPEntry 3 }
sipDS3PLCPUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
SNMP Working Group [Page 15]
RFC 1304 SIP Objects February 1992
"The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP."
::= { sipDS3PLCPEntry 4 }
-- The SMDS Applications group
-- Applications that have been identified for this group are:
-- * IP-over-SMDS (details are specified in RFC 1209)
-- Implementation of this group is mandatory for systems
-- that implement IP-over-SMDS Interface Protocol.
smdsApplications OBJECT IDENTIFIER ::= { sip 4 }
ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }
-- Although the objects in this group are read-only, at the
-- agent's discretion they may be made read-write so that the
-- management station, when appropriately authorized, may
-- change the addressing information related to the
-- configuration of a logical IP subnetwork implemented on
-- top of SMDS.
-- This table is necessary to support RFC1209 (IP-over-SMDS)
-- and gives information on the Group Addresses and ARP
-- Addresses used in the Logical IP subnetwork.
-- One SMDS address may be associated with multiple IP
-- addresses. One SNI may be associated with multiple LISs.
ipOverSMDSTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpOverSMDSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of addressing information relevant to
this entity's IP addresses."
::= { ipOverSMDS 1 }
ipOverSMDSEntry OBJECT-TYPE
SYNTAX IpOverSMDSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The addressing information for one of this
entity's IP addresses."
INDEX { ipOverSMDSIndex, ipOverSMDSAddress }
::= { ipOverSMDSTable 1 }
SNMP Working Group [Page 16]
RFC 1304 SIP Objects February 1992
IpOverSMDSEntry ::=
SEQUENCE {
ipOverSMDSIndex
INTEGER,
ipOverSMDSAddress
IpAddress,
ipOverSMDSHA
SMDSAddress,
ipOverSMDSLISGA
SMDSAddress,
ipOverSMDSARPReq
SMDSAddress
}
ipOverSMDSIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { ipOverSMDSEntry 1 }
ipOverSMDSAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address to which this entry's addressing
information pertains."
::= { ipOverSMDSEntry 2 }
ipOverSMDSHA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SMDS Individual address of the IP station."
::= { ipOverSMDSEntry 3 }
ipOverSMDSLISGA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
SNMP Working Group [Page 17]
RFC 1304 SIP Objects February 1992
DESCRIPTION
"The SMDS Group Address that has been configured
to identify the SMDS Subscriber-Network Interfaces
(SNIs) of all members of the Logical IP Subnetwork
(LIS) connected to the network supporting SMDS."
::= { ipOverSMDSEntry 4 }
ipOverSMDSARPReq OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SMDS address (individual or group) to which
ARP Requests are to be sent."
::= { ipOverSMDSEntry 5 }
-- The SMDS Carrier Selection group
-- This group is used as a place holder
-- for carrier selection objects.
smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}
-- The SIP Error Log
-- Implementation of this group is mandatory
-- for all systems that implement SIP Level 3.
sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }
sipL3PDUErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipL3PDUErrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains the latest occurrence of
the following syntactical SIP L3PDU errors:
- Destination Address Field Format Error,
The following pertains to the 60 least significant
bits of the 64 bit address field. The 60 bits
contained in the address subfield can be used to
represent addresses up to 15 decimal digits. Each
decimal digit shall be encoded into four bits
using Binary Coded Decimal (BCD), with the most
significant digit occurring left-most. If not all
15 digits are required, then the remainder of this
SNMP Working Group [Page 18]
RFC 1304 SIP Objects February 1992
field shall be padded on the right with bits set
to one. An error is considered to have occurred:
a). if the first four bits of the address
subfield are not BCD, OR b). if the first four
bits of the address subfield are populated with
the country code value 0001, AND the 40 bits which
follow are not Binary Coded Decimal (BCD) encoded
values of the 10 digit addresses, OR the remaining
16 least significant bits are not populated with
1's, OR c). if the address subfield is not
correct according to another numbering plan which
is dependent upon the carrier assigning the
numbers and offering SMDS.
- Source Address Field Format Error,
The description of this parameter is the same as
the description of the Destination Address Field
Format Error.
- Invalid BAsize Field Value,
An error is considered to have occurred when the
BAsize field of an SIP L3PDU contains a value less
that 32, greater than 9220 octets without the
CRC32 field present, greater than 9224 octets with
the CRC32 field present, or not equal to a
multiple of 4 octets,
- Invalid Header Extension Length Field Value,
An error is considered to have occurred when the
Header Extension Length field value is not equal
3.
- Invalid Header Extension - Element Length,
An error is considered to have occurred when the
Header Extension - Element Length is greater than
⌨️ 快捷键说明