📄 rfc1285.txt
字号:
snmpFddiSMTNonMasterCt
INTEGER,
snmpFddiSMTMasterCt
INTEGER,
Case [Page 6]
RFC 1285 FDDI MIB January 1992
snmpFddiSMTPathsAvailable
INTEGER,
snmpFddiSMTConfigCapabilities
INTEGER,
snmpFddiSMTConfigPolicy
INTEGER,
snmpFddiSMTConnectionPolicy
INTEGER,
snmpFddiSMTTNotify
INTEGER,
snmpFddiSMTStatusReporting
INTEGER,
snmpFddiSMTECMState
INTEGER,
snmpFddiSMTCFState
INTEGER,
snmpFddiSMTHoldState
INTEGER,
snmpFddiSMTRemoteDisconnectFlag
INTEGER,
snmpFddiSMTStationAction
INTEGER
}
snmpFddiSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { snmpFddiSMTEntry 1 }
snmpFddiSMTStationId OBJECT-TYPE
SYNTAX FddiSMTStationIdType -- OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Uniquely identifies an FDDI station."
REFERENCE
"ANSI { fddiSMT 11 }"
::= { snmpFddiSMTEntry 2 }
Case [Page 7]
RFC 1285 FDDI MIB January 1992
snmpFddiSMTOpVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The version that this station is using for its
operation (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 13 }"
::= { snmpFddiSMTEntry 3 }
snmpFddiSMTHiVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest version of SMT that this station
supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 14 }"
::= { snmpFddiSMTEntry 4 }
snmpFddiSMTLoVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The lowest version of SMT that this station
supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 15 }"
::= { snmpFddiSMTEntry 5 }
snmpFddiSMTMACCt OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of MACs in the station or
concentrator."
REFERENCE
"ANSI { fddiSMT 21 }"
::= { snmpFddiSMTEntry 6 }
snmpFddiSMTNonMasterCt OBJECT-TYPE
SYNTAX INTEGER (0..2)
ACCESS read-only
STATUS mandatory
Case [Page 8]
RFC 1285 FDDI MIB January 1992
DESCRIPTION
"The number of Non Master PORTs (A, B, or S PORTs)
in the station or concentrator."
REFERENCE
"ANSI { fddiSMT 22 }"
::= { snmpFddiSMTEntry 7 }
snmpFddiSMTMasterCt OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Master PORTs in a node. If the
node is not a concentrator, the value is zero."
REFERENCE
"ANSI { fddiSMT 23 }"
::= { snmpFddiSMTEntry 8 }
snmpFddiSMTPathsAvailable OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that indicates the PATH types available
in the station.
The value is a sum. This value initially takes
the value zero, then for each type of PATH that
this node has available, 2 raised to a power is
added to the sum. The powers are according to the
following table:
Path Power
Primary 0
Secondary 1
Local 2
For example, a station having Primary and Local
PATHs available would have a value of 5 (2**0 +
2**2)."
REFERENCE
"ANSI { fddiSMT 24 }"
::= { snmpFddiSMTEntry 9 }
snmpFddiSMTConfigCapabilities OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
Case [Page 9]
RFC 1285 FDDI MIB January 1992
DESCRIPTION
"A value that indicates capabilities that are
present in the node. If 'holdAvailable' is
present, this indicates support of the optional
Hold Function (refer to ANSI SMT 9.4.3.2). If
'CF-Wrap-AB' is present, this indicates that the
WRAP_AB state is forced.
The value is a sum. This value initially takes
the value zero, then for each of the configuration
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
holdAvailable 0
CF-Wrap-AB 1 "
REFERENCE
"ANSI { fddiSMT 25 }"
::= { snmpFddiSMTEntry 10 }
snmpFddiSMTConfigPolicy OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value that indicates the configuration policies
currently enforced in the node (refer to ANSI SMT
9.4.3.2). The 'configurationHold' policy refers
to the Hold flag, and should not be present only
if the Hold function is supported. The 'CF-Wrap-
AB' policy refers to the CF_Wrap_AB flag.
The value is a sum. This value initially takes
the value zero, then for each of the configuration
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
configurationHold 0
CF-Wrap-AB 1 "
REFERENCE
"ANSI { fddiSMT 26 }"
::= { snmpFddiSMTEntry 11 }
Case [Page 10]
RFC 1285 FDDI MIB January 1992
snmpFddiSMTConnectionPolicy OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value that indicates the connection policies
enforced at the station. A station sets the
corresponding policy for each of the connection
types that it rejects. The letter designations, X
and Y, in the 'rejectX-Y' names have the following
significance: X represents the PC-Type of the
local PORT and Y represents a PC-Neighbor in the
evaluation of Connection-Policy (PC-Type, PC-
Neighbor) that is done to determine the setting of
T-Val(3) in the PC-Signaling sequence (refer to
ANSI Section 9.6.3).
The value is a sum. This value initially takes
the value zero, then for each of the connection
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
rejectA-A 0
rejectA-B 1
rejectA-S 2
rejectA-M 3
rejectB-A 4
rejectB-B 5
rejectB-S 6
rejectB-M 7
rejectS-A 8
rejectS-B 9
rejectS-S 10
rejectS-M 11
rejectM-A 12
rejectM-B 13
rejectM-S 14
rejectM-M 15
Implementors should note that the polarity of
these bits is different in different places in an
SMT system. Implementors should take appropriate
care."
REFERENCE
"ANSI { fddiSMT 27 }"
::= { snmpFddiSMTEntry 12 }
Case [Page 11]
RFC 1285 FDDI MIB January 1992
snmpFddiSMTTNotify OBJECT-TYPE
SYNTAX INTEGER (2..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The timer used in the Neighbor Notification
protocol, reported in seconds and ranging from 2
to 30 seconds (refer to ANSI SMT 8.3.1)."
REFERENCE
"ANSI { fddiSMT 29 }"
::= { snmpFddiSMTEntry 13 }
snmpFddiSMTStatusReporting OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the node implements the Status
Reporting Protocol. This object is included for
compatibility with products that were designed
prior to the adoption of this standard."
REFERENCE
"ANSI { fddiSMT 30 }"
::= { snmpFddiSMTEntry 14 }
snmpFddiSMTECMState OBJECT-TYPE
SYNTAX INTEGER {
ec0(1), -- Out
ec1(2), -- In
ec2(3), -- Trace
ec3(4), -- Leave
ec4(5), -- Path_Test
ec5(6), -- Insert
ec6(7), -- Check
ec7(8) -- Deinsert
}
ACCESS read-only
STATUS mandatory
⌨️ 快捷键说明