⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1285.txt

📁 RFC 的详细文档!
💻 TXT
📖 第 1 页 / 共 5 页
字号:
                  snmpFddiSMTNonMasterCt
                      INTEGER,
                  snmpFddiSMTMasterCt
                      INTEGER,



Case                                                            [Page 6]

RFC 1285                        FDDI MIB                    January 1992


                  snmpFddiSMTPathsAvailable
                      INTEGER,
                  snmpFddiSMTConfigCapabilities
                      INTEGER,
                  snmpFddiSMTConfigPolicy
                      INTEGER,
                  snmpFddiSMTConnectionPolicy
                      INTEGER,
                  snmpFddiSMTTNotify
                      INTEGER,
                  snmpFddiSMTStatusReporting
                      INTEGER,
                  snmpFddiSMTECMState
                      INTEGER,
                  snmpFddiSMTCFState
                      INTEGER,
                  snmpFddiSMTHoldState
                      INTEGER,
                  snmpFddiSMTRemoteDisconnectFlag
                      INTEGER,
                  snmpFddiSMTStationAction
                      INTEGER
              }

          snmpFddiSMTIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A unique value for each SMT.  Its value ranges
                      between 1 and the value of snmpFddiSMTNumber.  The
                      value for each SMT must remain constant at least
                      from one re-initialization of the entity's network
                      management system to the next re-initialization."
              ::= { snmpFddiSMTEntry 1 }

          snmpFddiSMTStationId OBJECT-TYPE
              SYNTAX  FddiSMTStationIdType -- OCTET STRING (SIZE (8))
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "Uniquely identifies an FDDI station."
              REFERENCE
                      "ANSI { fddiSMT 11 }"
              ::= { snmpFddiSMTEntry 2 }






Case                                                            [Page 7]

RFC 1285                        FDDI MIB                    January 1992


          snmpFddiSMTOpVersionId OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The version that this station is using for its
                      operation (refer to ANSI 7.1.2.2)."
              REFERENCE
                      "ANSI { fddiSMT 13 }"
              ::= { snmpFddiSMTEntry 3 }

          snmpFddiSMTHiVersionId OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The highest version of SMT that this station
                      supports (refer to ANSI 7.1.2.2)."
              REFERENCE
                      "ANSI { fddiSMT 14 }"
              ::= { snmpFddiSMTEntry 4 }

          snmpFddiSMTLoVersionId OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The lowest version of SMT that this station
                      supports (refer to ANSI 7.1.2.2)."
              REFERENCE
                      "ANSI { fddiSMT 15 }"
              ::= { snmpFddiSMTEntry 5 }

          snmpFddiSMTMACCt OBJECT-TYPE
              SYNTAX  INTEGER (0..255)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of MACs in the station or
                      concentrator."
              REFERENCE
                      "ANSI { fddiSMT 21 }"
              ::= { snmpFddiSMTEntry 6 }

          snmpFddiSMTNonMasterCt OBJECT-TYPE
              SYNTAX  INTEGER (0..2)
              ACCESS  read-only
              STATUS  mandatory



Case                                                            [Page 8]

RFC 1285                        FDDI MIB                    January 1992


              DESCRIPTION
                      "The number of Non Master PORTs (A, B, or S PORTs)
                      in the station or concentrator."
              REFERENCE
                      "ANSI { fddiSMT 22 }"
              ::= { snmpFddiSMTEntry 7 }

          snmpFddiSMTMasterCt OBJECT-TYPE
              SYNTAX  INTEGER (0..255)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of Master PORTs in a node.  If the
                      node is not a concentrator, the value is zero."
              REFERENCE
                      "ANSI { fddiSMT 23 }"
              ::= { snmpFddiSMTEntry 8 }

          snmpFddiSMTPathsAvailable OBJECT-TYPE
              SYNTAX  INTEGER (0..7)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A value that indicates the PATH types available
                      in the station.

                      The value is a sum.  This value initially takes
                      the value zero, then for each type of PATH that
                      this node has available, 2 raised to a power is
                      added to the sum.  The powers are according to the
                      following table:

                               Path   Power
                            Primary   0
                          Secondary   1
                              Local   2

                      For example, a station having Primary and Local
                      PATHs available would have a value of 5 (2**0 +
                      2**2)."
              REFERENCE
                      "ANSI { fddiSMT 24 }"
              ::= { snmpFddiSMTEntry 9 }

          snmpFddiSMTConfigCapabilities OBJECT-TYPE
              SYNTAX  INTEGER (0..3)
              ACCESS  read-only
              STATUS  mandatory



Case                                                            [Page 9]

RFC 1285                        FDDI MIB                    January 1992


              DESCRIPTION
                      "A value that indicates capabilities that are
                      present in the node.  If 'holdAvailable' is
                      present, this indicates support of the optional
                      Hold Function (refer to ANSI SMT 9.4.3.2).  If
                      'CF-Wrap-AB' is present, this indicates that the
                      WRAP_AB state is forced.

                      The value is a sum.  This value initially takes
                      the value zero, then for each of the configuration
                      policies currently enforced on the node, 2 raised
                      to a power is added to the sum.  The powers are
                      according to the following table:

                                 Policy   Power
                          holdAvailable   0
                             CF-Wrap-AB   1 "
              REFERENCE
                      "ANSI { fddiSMT 25 }"
              ::= { snmpFddiSMTEntry 10 }

          snmpFddiSMTConfigPolicy OBJECT-TYPE
              SYNTAX  INTEGER (0..3)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "A value that indicates the configuration policies
                      currently enforced in the node (refer to ANSI SMT
                      9.4.3.2).  The 'configurationHold' policy refers
                      to the Hold flag, and should not be present only
                      if the Hold function is supported.  The 'CF-Wrap-
                      AB' policy refers to the CF_Wrap_AB flag.

                      The value is a sum.  This value initially takes
                      the value zero, then for each of the configuration
                      policies currently enforced on the node, 2 raised
                      to a power is added to the sum.  The powers are
                      according to the following table:

                                     Policy   Power
                          configurationHold   0
                                 CF-Wrap-AB   1 "
              REFERENCE
                      "ANSI { fddiSMT 26 }"
              ::= { snmpFddiSMTEntry 11 }






Case                                                           [Page 10]

RFC 1285                        FDDI MIB                    January 1992


          snmpFddiSMTConnectionPolicy OBJECT-TYPE
              SYNTAX  INTEGER (0..65535)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "A value that indicates the connection policies
                      enforced at the station.  A station sets the
                      corresponding policy for each of the connection
                      types that it rejects.  The letter designations, X
                      and Y, in the 'rejectX-Y' names have the following
                      significance:  X represents the PC-Type of the
                      local PORT and Y represents a PC-Neighbor in the
                      evaluation of Connection-Policy (PC-Type, PC-
                      Neighbor) that is done to determine the setting of
                      T-Val(3) in the PC-Signaling sequence (refer to
                      ANSI Section 9.6.3).

                      The value is a sum.  This value initially takes
                      the value zero, then for each of the connection
                      policies currently enforced on the node, 2 raised
                      to a power is added to the sum.  The powers are
                      according to the following table:

                             Policy   Power
                          rejectA-A   0
                          rejectA-B   1
                          rejectA-S   2
                          rejectA-M   3
                          rejectB-A   4
                          rejectB-B   5
                          rejectB-S   6
                          rejectB-M   7
                          rejectS-A   8
                          rejectS-B   9
                          rejectS-S   10
                          rejectS-M   11
                          rejectM-A   12
                          rejectM-B   13
                          rejectM-S   14
                          rejectM-M   15

                      Implementors should note that the polarity of
                      these bits is different in different places in an
                      SMT system.  Implementors should take appropriate
                      care."
              REFERENCE
                      "ANSI { fddiSMT 27 }"
              ::= { snmpFddiSMTEntry 12 }



Case                                                           [Page 11]

RFC 1285                        FDDI MIB                    January 1992


          snmpFddiSMTTNotify OBJECT-TYPE
              SYNTAX  INTEGER (2..30)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The timer used in the Neighbor Notification
                      protocol, reported in seconds and ranging from 2
                      to 30 seconds (refer to ANSI SMT 8.3.1)."
              REFERENCE
                      "ANSI { fddiSMT 29 }"
              ::= { snmpFddiSMTEntry 13 }

          snmpFddiSMTStatusReporting OBJECT-TYPE
              SYNTAX  INTEGER { true(1), false(2) }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "Indicates whether the node implements the Status
                      Reporting Protocol.  This object is included for
                      compatibility with products that were designed
                      prior to the adoption of this standard."
              REFERENCE
                      "ANSI { fddiSMT 30 }"
              ::= { snmpFddiSMTEntry 14 }

          snmpFddiSMTECMState OBJECT-TYPE
              SYNTAX  INTEGER {
                          ec0(1), -- Out
                          ec1(2), -- In
                          ec2(3), -- Trace
                          ec3(4), -- Leave
                          ec4(5), -- Path_Test
                          ec5(6), -- Insert
                          ec6(7), -- Check
                          ec7(8)  -- Deinsert
                      }
              ACCESS  read-only
              STATUS  mandatory

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -