📄 rfc1271.txt
字号:
::= { etherStatsEntry 16 }
etherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 17 }
etherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 18 }
Remote Network Monitoring Working Group [Page 17]
RFC 1271 Remote Network Monitoring MIB November 1991
etherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 19 }
etherStatsOwner OBJECT-TYPE
SYNTAX OwnerString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { etherStatsEntry 20 }
etherStatsStatus OBJECT-TYPE
SYNTAX EntryStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of this etherStats entry."
::= { etherStatsEntry 21 }
-- The History Group
-- Implementation of the History group is optional.
--
-- The history group records periodic statistical samples from
-- a network and stores them for later retrieval. The
-- historyControl table stores configuration entries that each
-- define an interface, polling period, and other parameters.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table. Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken. Currently the only media-
-- specific table defined is the etherHistoryTable, for
-- Ethernet networks.
--
-- If the probe keeps track of the time of day, it should
-- start the first sample of the history at a time such that
-- when the next hour of the day begins, a sample is
-- started at that instant. This tends to make more
Remote Network Monitoring Working Group [Page 18]
RFC 1271 Remote Network Monitoring MIB November 1991
-- user-friendly reports, and enables comparison of reports
-- from different probes that have relatively accurate time
-- of day.
--
-- The monitor is encouraged to add two history control entries
-- per monitored interface upon initialization that describe
-- a short term and a long term polling period. Suggested
-- parameters are 30 seconds for the short term polling
-- period and 30 minutes for the long term period.
historyControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HistoryControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of history control entries."
::= { history 1 }
historyControlEntry OBJECT-TYPE
SYNTAX HistoryControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of parameters that set up a periodic
sampling of statistics."
INDEX { historyControlIndex }
::= { historyControlTable 1 }
HistoryControlEntry ::= SEQUENCE {
historyControlIndex INTEGER (1..65535),
historyControlDataSource OBJECT IDENTIFIER,
historyControlBucketsRequested INTEGER (1..65535),
historyControlBucketsGranted INTEGER (1..65535),
historyControlInterval INTEGER (1..3600),
historyControlOwner OwnerString,
historyControlStatus INTEGER
}
historyControlIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies an entry in the
historyControl table. Each such entry defines a
set of samples at a particular interval for an
interface on the device."
::= { historyControlEntry 1 }
Remote Network Monitoring Working Group [Page 19]
RFC 1271 Remote Network Monitoring MIB November 1991
historyControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on behalf of this
historyControlEntry. This source can be any
interface on this device. In order to identify
a particular interface, this object shall identify
the instance of the ifIndex object, defined
in [4,6], for the desired interface. For example,
if an entry were to receive data from interface #1,
this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
::= { historyControlEntry 2 }
historyControlBucketsRequested OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated with this
historyControl entry.
When this object is created or modified, the probe
should set historyControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { historyControlEntry 3 }
historyControlBucketsGranted OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of discrete sampling intervals
over which data shall be saved in the part of
Remote Network Monitoring Working Group [Page 20]
RFC 1271 Remote Network Monitoring MIB November 1991
the media-specific table associated with this
historyControl entry.
When the associated historyControlBucketsRequested
object is created or modified, the probe
should set this object as closely to the requested
value as is possible for the particular
probe implementation and available resources. The
probe must not lower this value except as a result
of a modification to the associated
historyControlBucketsRequested object.
There will be times when the actual number of
buckets associated with this entry is less than
the value of this object. In this case, at the
end of each sampling interval, a new bucket will
be added to the media-specific table.
When the number of buckets reaches the value of
this object and a new bucket is to be added to the
media-specific table, the oldest bucket associated
with this historyControlEntry shall be deleted by
the agent so that the new bucket can be added.
When the value of this object changes to a value less
than the current value, entries are deleted
from the media-specific table associated with this
historyControlEntry. Enough of the oldest of these
entries shall be deleted by the agent so that their
number remains less than or equal to the new value of
this object.
When the value of this object changes to a value
greater than the current value, the number of
associated media-specific entries may be allowed
to grow."
::= { historyControlEntry 4 }
historyControlInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControl entry. This interval can
be set to any number of seconds between 1 and
Remote Network Monitoring Working Group [Page 21]
RFC 1271 Remote Network Monitoring MIB November 1991
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could overflow
in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
::= { historyControlEntry 5 }
historyControlOwner OBJECT-TYPE
SYNTAX OwnerString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { historyControlEntry 6 }
historyControlStatus OBJECT-TYPE
SYNTAX EntryStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of this historyControl entry.
Each instance of the media-specific table associated
with this historyControlEntry will be deleted by the
agent if this historyControlEntry is not equal to
valid(1)."
::= { historyControlEntry 7 }
-- Ether History table
etherHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherHistoryEntry
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D