📄 rfc1368.txt
字号:
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }
rptrAddrTrackGroupInfo -- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }
rptrAddrTrackPortInfo
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }
--
-- The BASIC GROUP
--
-- Implementation of the Basic Group is mandatory for all
-- managed repeaters.
--
-- Basic Repeater Information
--
-- Configuration, status, and control objects for the overall
-- repeater
--
rptrGroupCapacity OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rptrGroupCapacity is the number of groups
that can be contained within the repeater. Within
each managed repeater, the groups are uniquely
numbered in the range from 1 to rptrGroupCapacity.
Some groups may not be present in the repeater, in
which case the actual number of groups present
will be less than rptrGroupCapacity. The number
of groups present will never be greater than
rptrGroupCapacity.
Note: In practice, this will generally be the
number of field-replaceable units (i.e., modules,
cards, or boards) that can fit in the physical
repeater enclosure, and the group numbers will
correspond to numbers marked on the physical
enclosure."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterGroupCapacity."
McMaster & McCloghrie [Page 13]
RFC 1368 802.3 Repeater MIB October 1992
::= { rptrRptrInfo 1 }
rptrOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined or unknown status
ok(2), -- no known failures
rptrFailure(3), -- repeater-related failure
groupFailure(4), -- group-related failure
portFailure(5), -- port-related failure
generalFailure(6) -- failure, unspecified type
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rptrOperStatus object indicates the
operational state of the repeater. The
rptrHealthText object may be consulted for more
specific information about the state of the
repeater's health.
In the case of multiple kinds of failures (e.g.,
repeater failure and port failure), the value of
this attribute shall reflect the highest priority
failure in the following order:
rptrFailure(3)
groupFailure(4)
portFailure(5)
generalFailure(6)."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterHealthState."
::= { rptrRptrInfo 2 }
rptrHealthText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The health text object is a text string that
provides information relevant to the operational
state of the repeater. Agents may use this string
to provide detailed information on current
failures, including how they were detected, and/or
instructions for problem resolution. The contents
are agent-specific."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
McMaster & McCloghrie [Page 14]
RFC 1368 802.3 Repeater MIB October 1992
aRepeaterHealthText."
::= { rptrRptrInfo 3 }
rptrReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to reset(2) causes a
transition to the START state of Fig 9-2 in
section 9 [IEEE 802.3 Std].
Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.
This action does not reset the management counters
defined in this document nor does it affect the
portAdminStatus parameters. Included in this
action is the execution of a disruptive Self-Test
with the following characteristics: a) The nature
of the tests is not specified. b) The test resets
the repeater but without affecting management
information about the repeater. c) The test does
not inject packets onto any segment. d) Packets
received during the test may or may not be
transferred. e) The test does not interfere with
management functions.
As a result of this action a rptrResetEvent trap
should be sent."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acResetRepeater."
::= { rptrRptrInfo 4 }
rptrNonDisruptTest OBJECT-TYPE
SYNTAX INTEGER {
noSelfTest(1),
selfTest(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to selfTest(2) causes the
McMaster & McCloghrie [Page 15]
RFC 1368 802.3 Repeater MIB October 1992
repeater to perform a agent-specific, non-
disruptive self-test that has the following
characteristics: a) The nature of the tests is
not specified. b) The test does not change the
state of the repeater or management information
about the repeater. c) The test does not inject
packets onto any segment. d) The test does not
prevent the relay of any packets. e) The test
does not interfere with management functions.
After performing this test the agent will update
the repeater health information and send a
rptrHealth trap.
Setting this object to noSelfTest(1) has no
effect. The agent will always return the value
noSelfTest(1) when this object is read."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acExecuteNonDisruptiveSelfTest."
::= { rptrRptrInfo 5 }
rptrTotalPartitionedPorts OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the total number of ports in
the repeater whose current state meets all three
of the following criteria: rptrPortOperStatus
does not have the value notPresent(3),
rptrPortAdminStatus is enabled(1), and
rptrPortAutoPartitionState is autoPartitioned(2)."
::= { rptrRptrInfo 6 }
--
-- The Basic Port Group Table
--
rptrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of descriptive and status information about
the groups of ports."
::= { rptrGroupInfo 1 }
McMaster & McCloghrie [Page 16]
RFC 1368 802.3 Repeater MIB October 1992
rptrGroupEntry OBJECT-TYPE
SYNTAX RptrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing information
about a single group of ports."
INDEX { rptrGroupIndex }
::= { rptrGroupTable 1 }
RptrGroupEntry ::=
SEQUENCE {
rptrGroupIndex
INTEGER,
rptrGroupDescr
DisplayString,
rptrGroupObjectID
OBJECT IDENTIFIER,
rptrGroupOperStatus
INTEGER,
rptrGroupLastOperStatusChange
TimeTicks,
rptrGroupPortCapacity
INTEGER
}
rptrGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group within the
repeater for which this entry contains
information. This value is never greater than
rptrGroupCapacity."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.5.2,
aGroupID."
::= { rptrGroupEntry 1 }
rptrGroupDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the group. This value
should include the full name and version
identification of the group's hardware type and
McMaster & McCloghrie [Page 17]
RFC 1368 802.3 Repeater MIB October 1992
indicate how the group is differentiated from
other groups in the repeater. Plug-in Module, Rev
A' or 'Barney Rubble 10BASE-T 4-port SIMM socket
Version 2.1' are examples of valid group
descriptions.
It is mandatory that this only contain printable
ASCII characters."
::= { rptrGroupEntry 2 }
rptrGroupObjectID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vendor's authoritative identification of the
group. This value is allocated within the SMI
enterprises subtree (1.3.6.1.4.1) and provides a
straight-forward and unambiguous means for
determining what kind of group is being managed.
For example, this object could take the value
1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
and had assigned the identifier
1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
6-Port FOIRL Plug-in Module.'"
::= { rptrGroupEntry 3 }
rptrGroupOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
operational(2),
malfunctioning(3),
notPresent(4),
underTest(5),
resetInProgress(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An object that indicates the operational status
of the group.
A status of notPresent(4) indicates that the group
is temporarily or permanently physically and/or
logically not a part of the repeater. It is an
implementation-specific matter as to whether the
McMaster & McCloghrie [Page 18]
RFC 1368 802.3 Repeater MIB October 1992
agent effectively removes notPresent entries from
the table.
A status of operational(2) indicates that the
group is functioning, and a status of
malfunctioning(3) indicates that the group is
malfunctioning in some way."
::= { rptrGroupEntry 4 }