RFC 1659                    RS-232-like MIB                    July 1994


   rs232AsyncPortIndex OBJECT-TYPE
       SYNTAX InterfaceIndex
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "A unique value for each port.  Its value is the
           same as rs232PortIndex for the port."
       ::= { rs232AsyncPortEntry 1 }

   rs232AsyncPortBits OBJECT-TYPE
       SYNTAX INTEGER (5..8)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The port's number of bits in a character."
       ::= { rs232AsyncPortEntry 2 }

   rs232AsyncPortStopBits OBJECT-TYPE
       SYNTAX INTEGER { one(1), two(2),
                        oneAndHalf(3), dynamic(4) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The port's number of stop bits."
       ::= { rs232AsyncPortEntry 3 }

   rs232AsyncPortParity OBJECT-TYPE
       SYNTAX INTEGER { none(1), odd(2), even(3),
                        mark(4), space(5) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The port's sense of a character parity bit."
       ::= { rs232AsyncPortEntry 4 }

   rs232AsyncPortAutobaud OBJECT-TYPE
       SYNTAX INTEGER { enabled(1), disabled(2) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "A control for the port's ability to automatically
           sense input speed.

           When rs232PortAutoBaud is 'enabled', a port may
           autobaud to values different from the set values for
           speed, parity, and character size.  As a result a
           network management system may temporarily observe
           values different from what was previously set."



Stewart                                                         [Page 8]

RFC 1659                    RS-232-like MIB                    July 1994


       ::= { rs232AsyncPortEntry 5 }

   rs232AsyncPortParityErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of characters with a parity error,
           input from the port since system re-initialization
           and while the port state was 'up' or 'test'."
       ::= { rs232AsyncPortEntry 6 }

   rs232AsyncPortFramingErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of characters with a framing error,
           input from the port since system re-initialization
           and while the port state was 'up' or 'test'."
       ::= { rs232AsyncPortEntry 7 }

   rs232AsyncPortOverrunErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of characters with an overrun error,
           input from the port since system re-initialization
           and while the port state was 'up' or 'test'."
       ::= { rs232AsyncPortEntry 8 }


   -- RS-232-like Synchronous Port Table

   rs232SyncPortTable OBJECT-TYPE
       SYNTAX SEQUENCE OF Rs232SyncPortEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "A list of asynchronous port entries.  Entries need
           not exist for synchronous ports."
       ::= { rs232 4 }

   rs232SyncPortEntry OBJECT-TYPE
       SYNTAX Rs232SyncPortEntry
       MAX-ACCESS not-accessible
       STATUS current



Stewart                                                         [Page 9]

RFC 1659                    RS-232-like MIB                    July 1994


       DESCRIPTION
           "Status and parameter values for a synchronous
           port."
       INDEX { rs232SyncPortIndex }
       ::= { rs232SyncPortTable 1 }

   Rs232SyncPortEntry ::=
       SEQUENCE {
           rs232SyncPortIndex
               InterfaceIndex,
           rs232SyncPortClockSource
               INTEGER,
           rs232SyncPortFrameCheckErrs
               Counter32,
           rs232SyncPortTransmitUnderrunErrs
               Counter32,
           rs232SyncPortReceiveOverrunErrs
               Counter32,
           rs232SyncPortInterruptedFrames
               Counter32,
           rs232SyncPortAbortedFrames
               Counter32,
           rs232SyncPortRole
               INTEGER,
           rs232SyncPortEncoding
               INTEGER,
           rs232SyncPortRTSControl
               INTEGER,
           rs232SyncPortRTSCTSDelay
               Integer32,
           rs232SyncPortMode
               INTEGER,
           rs232SyncPortIdlePattern
               INTEGER,
           rs232SyncPortMinFlags
               Integer32
       }

   rs232SyncPortIndex OBJECT-TYPE
       SYNTAX InterfaceIndex
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "A unique value for each port.  Its value is the
           same as rs232PortIndex for the port."
       ::= { rs232SyncPortEntry 1 }





Stewart                                                        [Page 10]

RFC 1659                    RS-232-like MIB                    July 1994


   rs232SyncPortClockSource OBJECT-TYPE
       SYNTAX INTEGER { internal(1), external(2), split(3) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Source of the port's bit rate clock. 'split' means
           the tranmit clock is internal and the receive clock
           is external."
       ::= { rs232SyncPortEntry 2 }

   rs232SyncPortFrameCheckErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of frames with an invalid frame check
           sequence, input from the port since system
           re-initialization and while the port state was 'up'
           or 'test'."
       ::= { rs232SyncPortEntry 3 }

   rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of frames that failed to be
           transmitted on the port since system
           re-initialization and while the port state was 'up'
           or 'test' because data was not available to the
           transmitter in time."
       ::= { rs232SyncPortEntry 4 }

   rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Total number of frames that failed to be received
           on the port since system re-initialization and while
           the port state was 'up' or 'test' because the
           receiver did not accept the data in time."
       ::= { rs232SyncPortEntry 5 }

   rs232SyncPortInterruptedFrames OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current



Stewart                                                        [Page 11]

RFC 1659                    RS-232-like MIB                    July 1994


       DESCRIPTION
           "Total number of frames that failed to be received
           or transmitted on the port due to loss of modem
           signals since system re-initialization and while the
           port state was 'up' or 'test'."
       ::= { rs232SyncPortEntry 6 }

   rs232SyncPortAbortedFrames OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Number of frames aborted on the port due to
           receiving an abort sequence since system
           re-initialization and while the port state was 'up'
           or 'test'."
       ::= { rs232SyncPortEntry 7 }

   rs232SyncPortRole OBJECT-TYPE
       SYNTAX INTEGER  { dte(1), dce(2) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The role the device is playing that is using this port.
              dte    means the device is performing the role of
                     data terminal equipment
              dce    means the device is performing the role of
                     data circuit-terminating equipment."
       DEFVAL { dce }
       ::= { rs232SyncPortEntry 8 }

   rs232SyncPortEncoding OBJECT-TYPE
       SYNTAX INTEGER  { nrz(1), nrzi(2) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The bit stream encoding technique that is in effect
            for this port.
              nrz    for Non-Return to Zero encoding
              nrzi   for Non-Return to Zero Inverted encoding."
       DEFVAL { nrz }
       ::= { rs232SyncPortEntry 9 }

   rs232SyncPortRTSControl OBJECT-TYPE
       SYNTAX INTEGER  { controlled(1), constant(2) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION



Stewart                                                        [Page 12]

RFC 1659                    RS-232-like MIB                    July 1994


           "The method used to control the Request To Send (RTS)
            signal.

              controlled  when the DTE is asserts RTS each time
                          data needs to be transmitted and drops
                          RTS at some point after data
                          transmission begins.

                          If rs232SyncPortRole is 'dte', the
                          RTS is an output signal. The device
                          will issue a RTS and wait for a CTS
                          from the DCE before starting to
                          transmit.

                          If rs232SyncPortRole is 'dce', the
                          RTS is an input signal. The device
                          will issue a CTS only after having
                          received RTS and waiting the
                          rs232SyncPortRTSCTSDelay interval.

              constant    when the DTE constantly asserts RTS."
       DEFVAL { constant }
       ::= { rs232SyncPortEntry 10 }

   rs232SyncPortRTSCTSDelay OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The interval (in milliseconds) that the DCE must wait
            after it sees RTS asserted before asserting CTS.  This
            object exists in support of older synchronous devices
            that cannot recognize CTS within a certain interval
            after it asserts RTS."
       DEFVAL { 0 }
       ::= { rs232SyncPortEntry 11 }

   rs232SyncPortMode OBJECT-TYPE
       SYNTAX INTEGER  { fdx(1), hdx(2), simplex-receive(3),
                         simplex-send(4) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The mode of operation of the port with respect to the
            direction and simultaneity of data transfer.






Stewart                                                        [Page 13]

RFC 1659                    RS-232-like MIB                    July 1994


              fdx              when frames on the data link can be
                               transmitted and received at the same
                               time

              hdx              when frames can either be received
                               from the data link or transmitted
                               onto the data link but not at the
                               same time.

              simplex-receive  when frames can only be received on
                               this data link.

              simplex-send     when frames can only be sent on this
                               data link."
       DEFVAL { fdx }
       ::= { rs232SyncPortEntry 12 }

   rs232SyncPortIdlePattern OBJECT-TYPE
       SYNTAX INTEGER  { mark(1), space(2) }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The bit pattern used to indicate an idle line."
       DEFVAL { space }
       ::= { rs232SyncPortEntry 13 }

   rs232SyncPortMinFlags OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "The minimum number of flag patterns this port needs in
            order to recognize the end of one frame and the start
            of the next.  Plausible values are 1 and 2."
       DEFVAL { 2 }
       ::= { rs232SyncPortEntry 14 }


   -- Input Signal Table

   rs232InSigTable OBJECT-TYPE
       SYNTAX SEQUENCE OF Rs232InSigEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "A list of port input control signal entries
           implemented and visible to the software on the port,
           and useful to monitor."



Stewart                                                        [Page 14]

RFC 1659                    RS-232-like MIB                    July 1994