⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2213.txt

📁 RFC 的详细文档!
💻 TXT
📖 第 1 页 / 共 3 页
字号:


        DESCRIPTION
           "The number of packets policed since the incep-
           tion of the flow's service."
       ::= { intSrvFlowEntry 21 }


    intSrvFlowDiscard OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "If 'true', the flow  is  to  incur  loss  when
           traffic is policed.  If 'false', policed traff-
           ic is treated as best effort traffic."
       DEFVAL { false } -- traffic is, by default, treated as best
                        -- effort
       ::= { intSrvFlowEntry 22 }


    intSrvFlowService OBJECT-TYPE
        SYNTAX      QosService
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
           "The QoS service being applied to this flow."
       ::= { intSrvFlowEntry 23 }


    intSrvFlowOrder OBJECT-TYPE
        SYNTAX      INTEGER (0..65535)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "In the event of ambiguity, the order in  which
           the  classifier  should  make  its comparisons.
           The row with intSrvFlowOrder=0 is tried  first,
           and  comparisons  proceed  in  the order of in-
           creasing value.  Non-serial implementations  of
           the classifier should emulate this behavior."
       ::= { intSrvFlowEntry 24 }


    intSrvFlowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "'active' for all active  flows.   This  object



Baker, et. al.              Standards Track                    [Page 15]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


           may be used to install static classifier infor-
           mation, delete classifier information,  or  au-
           thorize such."
       ::= { intSrvFlowEntry 25 }


    intSrvFlowNewIndex OBJECT-TYPE
        SYNTAX      TestAndIncr
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
           "This  object  is  used  to  assign  values  to
           intSrvFlowNumber  as described in 'Textual Con-
           ventions  for  SNMPv2'.   The  network  manager
           reads  the  object,  and  then writes the value
           back in the SET that creates a new instance  of
           intSrvFlowEntry.   If  the  SET  fails with the
           code 'inconsistentValue', then the process must
           be  repeated; If the SET succeeds, then the ob-
           ject is incremented, and the  new  instance  is
           created according to the manager's directions."
       ::= { intSrvGenObjects 1 }


-- conformance information


intSrvGroups      OBJECT IDENTIFIER ::= { intSrvConformance 1 }
intSrvCompliances OBJECT IDENTIFIER ::= { intSrvConformance 2 }

-- compliance statements


    intSrvCompliance MODULE-COMPLIANCE
        STATUS  current
        DESCRIPTION
           "The compliance statement "
       MODULE  -- this module
       MANDATORY-GROUPS { intSrvIfAttribGroup, intSrvFlowsGroup }

       OBJECT       intSrvFlowType
         MIN-ACCESS read-only
         DESCRIPTION
          "read-create access is not required. This may be
          read-only."

      OBJECT       intSrvFlowOwner
        MIN-ACCESS read-only



Baker, et. al.              Standards Track                    [Page 16]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


        DESCRIPTION
         "read-create access is not required. This may  be
         read-only."

     OBJECT       intSrvFlowDestAddr
       MIN-ACCESS read-only
       DESCRIPTION
        "read-create access is not required. This  may  be
        read-only."

    OBJECT       intSrvFlowSenderAddr
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowDestAddrLength
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowSenderAddrLength
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowProtocol
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowDestPort
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowPort
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowFlowId
      MIN-ACCESS not-accessible



Baker, et. al.              Standards Track                    [Page 17]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


      DESCRIPTION
       "This object is needed only in a system that imple-
       ments IPv6."

    OBJECT       intSrvFlowInterface
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowRate
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowBurst
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowWeight
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowQueue
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowMinTU
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowMaxTU
      MIN-ACCESS read-only
      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    OBJECT       intSrvFlowStatus
      MIN-ACCESS read-only



Baker, et. al.              Standards Track                    [Page 18]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


      DESCRIPTION
       "read-create access is not required.  This  may  be
       read-only."

    ::= { intSrvCompliances 1 }


    intSrvIfAttribGroup OBJECT-GROUP
         OBJECTS {
            intSrvIfAttribAllocatedBits, intSrvIfAttribMaxAllocatedBits,
            intSrvIfAttribAllocatedBuffer, intSrvIfAttribFlows,
            intSrvIfAttribPropagationDelay, intSrvIfAttribStatus
        }
        STATUS  current
        DESCRIPTION
           "These objects are required  for  Systems  sup-
           porting the Integrated Services Architecture."
       ::= { intSrvGroups 1 }

    intSrvFlowsGroup OBJECT-GROUP
         OBJECTS {
            intSrvFlowType, intSrvFlowOwner, intSrvFlowDestAddr,
            intSrvFlowSenderAddr, intSrvFlowDestAddrLength,
            intSrvFlowSenderAddrLength, intSrvFlowProtocol,
            intSrvFlowDestPort, intSrvFlowPort, intSrvFlowInterface,
            intSrvFlowBestEffort, intSrvFlowRate, intSrvFlowBurst,
            intSrvFlowWeight, intSrvFlowQueue, intSrvFlowMinTU,
            intSrvFlowDiscard, intSrvFlowPoliced, intSrvFlowService,
            intSrvFlowIfAddr, intSrvFlowOrder, intSrvFlowStatus
        }
        STATUS  current
        DESCRIPTION
           "These objects are required  for  Systems  sup-
           porting the Integrated Services Architecture."
       ::= { intSrvGroups 2 }

END

4.  Security Considerations

   The use of an SNMP SET results in an RSVP or Integrated Services
   reservation under rules that are different compared to if the
   reservation was negotiated using RSVP. However, no other security
   considerations exist other than those imposed by SNMP itself.







Baker, et. al.              Standards Track                    [Page 19]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


5.  Authors' Addresses

            Fred Baker
    Postal: Cisco Systems
            519 Lado Drive
            Santa Barbara, California 93111

    Phone:  +1 805 681 0115
    EMail:  fred@cisco.com


            John Krawczyk
    Postal: ArrowPoint Communications
            235 Littleton Road
            Westford, Massachusetts 01886

    Phone:  +1 508 692 5875
    EMail:  jjk@tiac.net


            Arun Sastry
    Postal: Cisco Systems
            210 W. Tasman Drive
            San Jose, California 95314
    Phone:  +1 408 526 7685
    EMail:  arun@cisco.com

6.  Acknowledgements

   This document was produced by the Integrated Services Working Group.

   The authors would like to thank the following people for providing
   feedback on this document:

   Lou Berger, Fore Systems
   Bob Braden, ISI
   Viswanatha Rao, Compaq
   John Wroclawski, MIT

7.  References

   [1]  Rose, M., Editor, "Management Information Base for Network
   Management of TCP/IP-based internets", STD 17, RFC 1213, May 1990.

   [2]  Information processing systems - Open Systems
   Interconnection - Specification of Abstract Syntax
   Notation One (ASN.1), International Organization for
   Standardization.  International Standard 8824, (December,



Baker, et. al.              Standards Track                    [Page 20]

RFC 2213          Integrated Services MIB using SMIv2     September 1997


   1987).

   [3]  Information processing systems - Open Systems
   Interconnection - Specification of Basic Encoding Rules
   for Abstract Notation One (ASN.1), International
   Organization for Standardization.  International Standard
   8825, (December, 1987).












































Baker, et. al.              Standards Track                    [Page 21]


⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -