📄 rfc2213.txt
字号:
DESCRIPTION
"The number of packets policed since the incep-
tion of the flow's service."
::= { intSrvFlowEntry 21 }
intSrvFlowDiscard OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If 'true', the flow is to incur loss when
traffic is policed. If 'false', policed traff-
ic is treated as best effort traffic."
DEFVAL { false } -- traffic is, by default, treated as best
-- effort
::= { intSrvFlowEntry 22 }
intSrvFlowService OBJECT-TYPE
SYNTAX QosService
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The QoS service being applied to this flow."
::= { intSrvFlowEntry 23 }
intSrvFlowOrder OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In the event of ambiguity, the order in which
the classifier should make its comparisons.
The row with intSrvFlowOrder=0 is tried first,
and comparisons proceed in the order of in-
creasing value. Non-serial implementations of
the classifier should emulate this behavior."
::= { intSrvFlowEntry 24 }
intSrvFlowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"'active' for all active flows. This object
Baker, et. al. Standards Track [Page 15]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
may be used to install static classifier infor-
mation, delete classifier information, or au-
thorize such."
::= { intSrvFlowEntry 25 }
intSrvFlowNewIndex OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to assign values to
intSrvFlowNumber as described in 'Textual Con-
ventions for SNMPv2'. The network manager
reads the object, and then writes the value
back in the SET that creates a new instance of
intSrvFlowEntry. If the SET fails with the
code 'inconsistentValue', then the process must
be repeated; If the SET succeeds, then the ob-
ject is incremented, and the new instance is
created according to the manager's directions."
::= { intSrvGenObjects 1 }
-- conformance information
intSrvGroups OBJECT IDENTIFIER ::= { intSrvConformance 1 }
intSrvCompliances OBJECT IDENTIFIER ::= { intSrvConformance 2 }
-- compliance statements
intSrvCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement "
MODULE -- this module
MANDATORY-GROUPS { intSrvIfAttribGroup, intSrvFlowsGroup }
OBJECT intSrvFlowType
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowOwner
MIN-ACCESS read-only
Baker, et. al. Standards Track [Page 16]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowDestAddr
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowSenderAddr
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowDestAddrLength
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowSenderAddrLength
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowProtocol
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowDestPort
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowPort
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowFlowId
MIN-ACCESS not-accessible
Baker, et. al. Standards Track [Page 17]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
DESCRIPTION
"This object is needed only in a system that imple-
ments IPv6."
OBJECT intSrvFlowInterface
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowRate
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowBurst
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowWeight
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowQueue
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowMinTU
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowMaxTU
MIN-ACCESS read-only
DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT intSrvFlowStatus
MIN-ACCESS read-only
Baker, et. al. Standards Track [Page 18]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
DESCRIPTION
"read-create access is not required. This may be
read-only."
::= { intSrvCompliances 1 }
intSrvIfAttribGroup OBJECT-GROUP
OBJECTS {
intSrvIfAttribAllocatedBits, intSrvIfAttribMaxAllocatedBits,
intSrvIfAttribAllocatedBuffer, intSrvIfAttribFlows,
intSrvIfAttribPropagationDelay, intSrvIfAttribStatus
}
STATUS current
DESCRIPTION
"These objects are required for Systems sup-
porting the Integrated Services Architecture."
::= { intSrvGroups 1 }
intSrvFlowsGroup OBJECT-GROUP
OBJECTS {
intSrvFlowType, intSrvFlowOwner, intSrvFlowDestAddr,
intSrvFlowSenderAddr, intSrvFlowDestAddrLength,
intSrvFlowSenderAddrLength, intSrvFlowProtocol,
intSrvFlowDestPort, intSrvFlowPort, intSrvFlowInterface,
intSrvFlowBestEffort, intSrvFlowRate, intSrvFlowBurst,
intSrvFlowWeight, intSrvFlowQueue, intSrvFlowMinTU,
intSrvFlowDiscard, intSrvFlowPoliced, intSrvFlowService,
intSrvFlowIfAddr, intSrvFlowOrder, intSrvFlowStatus
}
STATUS current
DESCRIPTION
"These objects are required for Systems sup-
porting the Integrated Services Architecture."
::= { intSrvGroups 2 }
END
4. Security Considerations
The use of an SNMP SET results in an RSVP or Integrated Services
reservation under rules that are different compared to if the
reservation was negotiated using RSVP. However, no other security
considerations exist other than those imposed by SNMP itself.
Baker, et. al. Standards Track [Page 19]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
5. Authors' Addresses
Fred Baker
Postal: Cisco Systems
519 Lado Drive
Santa Barbara, California 93111
Phone: +1 805 681 0115
EMail: fred@cisco.com
John Krawczyk
Postal: ArrowPoint Communications
235 Littleton Road
Westford, Massachusetts 01886
Phone: +1 508 692 5875
EMail: jjk@tiac.net
Arun Sastry
Postal: Cisco Systems
210 W. Tasman Drive
San Jose, California 95314
Phone: +1 408 526 7685
EMail: arun@cisco.com
6. Acknowledgements
This document was produced by the Integrated Services Working Group.
The authors would like to thank the following people for providing
feedback on this document:
Lou Berger, Fore Systems
Bob Braden, ISI
Viswanatha Rao, Compaq
John Wroclawski, MIT
7. References
[1] Rose, M., Editor, "Management Information Base for Network
Management of TCP/IP-based internets", STD 17, RFC 1213, May 1990.
[2] Information processing systems - Open Systems
Interconnection - Specification of Abstract Syntax
Notation One (ASN.1), International Organization for
Standardization. International Standard 8824, (December,
Baker, et. al. Standards Track [Page 20]
RFC 2213 Integrated Services MIB using SMIv2 September 1997
1987).
[3] Information processing systems - Open Systems
Interconnection - Specification of Basic Encoding Rules
for Abstract Notation One (ASN.1), International
Organization for Standardization. International Standard
8825, (December, 1987).
Baker, et. al. Standards Track [Page 21]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -