          ::= { atmInterfaceConfEntry 5}

     atmInterfaceMaxActiveVciBits  OBJECT-TYPE
          SYNTAX         INTEGER (0..16)
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "The maximum number of active VCI bits
            configured for use at this ATM interface."
          ::= { atmInterfaceConfEntry 6}

     atmInterfaceIlmiVpi OBJECT-TYPE
          SYNTAX         AtmVpIdentifier
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "The VPI value of the VCC supporting
            the ILMI at this ATM interface.  If the values of
            atmInterfaceIlmiVpi and atmInterfaceIlmiVci are
            both equal to zero then the ILMI is not
            supported at this ATM interface."
          DEFVAL { 0 }
          ::= { atmInterfaceConfEntry 7}

     atmInterfaceIlmiVci OBJECT-TYPE
          SYNTAX         AtmVcIdentifier



Tesink                      Standards Track                    [Page 24]

RFC 2515                 ATM Management Objects            February 1999


          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "The VCI value of the VCC supporting
            the ILMI at this ATM interface.  If the values of
            atmInterfaceIlmiVpi and atmInterfaceIlmiVci are
            both equal to zero then the ILMI is not
            supported at this ATM interface."
          DEFVAL { 16 }
          ::= { atmInterfaceConfEntry 8}

     atmInterfaceAddressType  OBJECT-TYPE
          SYNTAX         INTEGER {
                            private(1),
                            nsapE164(2),
                            nativeE164(3),
                            other(4)
                              }
          MAX-ACCESS     read-only
          STATUS         deprecated
          DESCRIPTION
           "The type of primary ATM address configured
            for use at this ATM interface."
          ::= { atmInterfaceConfEntry 9 }

     --  The atmInterfaceAdminAddress object has been replaced by
     --  atmInterfaceSubscrAddress.

     atmInterfaceAdminAddress OBJECT-TYPE
          SYNTAX         AtmAddr
          MAX-ACCESS     read-only
          STATUS         deprecated
          DESCRIPTION
           "The primary address assigned for administrative purposes,
            for example, an address associated with the
            service provider side of a public network UNI
            (thus, the value of this address corresponds
            with the value of ifPhysAddress at the host side).
            If this interface has no assigned administrative
            address, or when the address used for
            administrative purposes is the same as that used
            for ifPhysAddress, then this is an octet string of
            zero length."
          ::= { atmInterfaceConfEntry 10 }

     atmInterfaceMyNeighborIpAddress OBJECT-TYPE
          SYNTAX         IpAddress
          MAX-ACCESS     read-write



Tesink                      Standards Track                    [Page 25]

RFC 2515                 ATM Management Objects            February 1999


          STATUS         current
          DESCRIPTION
           "The IP address of the neighbor system connected to
            the  far end of this interface, to which a Network
            Management Station can send SNMP messages, as IP
            datagrams sent to UDP port 161, in order to access
            network management information concerning the
            operation of that system.  Note that the value
            of this object may be obtained in different ways,
            e.g., by manual configuration, or through ILMI
            interaction with the neighbor system."
          ::= { atmInterfaceConfEntry 11 }

     atmInterfaceMyNeighborIfName OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "The textual name of the interface on the neighbor
            system on the far end of this interface, and to
            which this interface connects.  If the neighbor
            system is manageable through SNMP and supports
            the object ifName, the value of this object must
            be identical with that of ifName for the ifEntry
            of the lowest level physical interface
            for this port.  If this interface does not have a
            textual name, the value of this object is a zero
            length string.  Note that the value of this object
            may be obtained in different ways, e.g., by manual
            configuration, or through ILMI interaction with
            the neighbor system."
          ::= { atmInterfaceConfEntry 12 }

     atmInterfaceCurrentMaxVpiBits    OBJECT-TYPE
          SYNTAX         INTEGER  (0..12)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The maximum number of VPI Bits that may
            currently be used at this ATM interface.
            The value is the minimum of
            atmInterfaceMaxActiveVpiBits, and the
            atmInterfaceMaxActiveVpiBits of the interface's
            UNI/NNI peer.

            If the interface does not negotiate with
            its peer to determine the number of VPI Bits
            that can be used on the interface, then the



Tesink                      Standards Track                    [Page 26]

RFC 2515                 ATM Management Objects            February 1999


            value of this object must equal
            atmInterfaceMaxActiveVpiBits."
          ::= { atmInterfaceConfEntry 13 }

     atmInterfaceCurrentMaxVciBits    OBJECT-TYPE
          SYNTAX         INTEGER  (0..16)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The maximum number of VCI Bits that may
            currently be used at this ATM interface.
            The value is the minimum of
            atmInterfaceMaxActiveVciBits, and the
            atmInterfaceMaxActiveVciBits of the interface's
            UNI/NNI peer.

            If the interface does not negotiate with
            its peer to determine the number of VCI Bits
            that can be used on the interface, then the
            value of this object must equal
            atmInterfaceMaxActiveVciBits."
          ::= { atmInterfaceConfEntry 14 }

     atmInterfaceSubscrAddress OBJECT-TYPE
          SYNTAX         AtmAddr
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "The identifier assigned by a service provider
            to the network side of a public network UNI.
            If this interface has no assigned service provider
            address, or for other interfaces this is an octet string
            of zero length."
          ::= { atmInterfaceConfEntry 15 }

     -- The ATM Interface DS3 PLCP Table

     -- This table contains the DS3 PLCP configuration and
     -- state parameters of those ATM interfaces
     -- which use DS3 PLCP for carrying ATM cells over DS3.

     atmInterfaceDs3PlcpTable  OBJECT-TYPE
          SYNTAX       SEQUENCE OF AtmInterfaceDs3PlcpEntry
          MAX-ACCESS   not-accessible
          STATUS       current
          DESCRIPTION
           "This table contains ATM interface DS3 PLCP
            parameters and state variables, one entry per



Tesink                      Standards Track                    [Page 27]

RFC 2515                 ATM Management Objects            February 1999


            ATM interface port."
          ::= { atmMIBObjects 3}

     atmInterfaceDs3PlcpEntry OBJECT-TYPE
          SYNTAX         AtmInterfaceDs3PlcpEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This list contains DS3 PLCP parameters and
            state variables at the ATM interface and is
            indexed by the ifIndex value of the ATM interface."
          INDEX    { ifIndex }
          ::= { atmInterfaceDs3PlcpTable 1}

     AtmInterfaceDs3PlcpEntry    ::= SEQUENCE  {
          atmInterfaceDs3PlcpSEFSs       Counter32,
          atmInterfaceDs3PlcpAlarmState  INTEGER,
          atmInterfaceDs3PlcpUASs        Counter32
            }


     atmInterfaceDs3PlcpSEFSs  OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of DS3 PLCP Severely Errored Framing
            Seconds (SEFS). Each SEFS represents a
            one-second interval which contains
            one or more SEF events."
          ::= { atmInterfaceDs3PlcpEntry 1}

     atmInterfaceDs3PlcpAlarmState    OBJECT-TYPE
          SYNTAX         INTEGER {
                            noAlarm(1),
                            receivedFarEndAlarm(2),
                            incomingLOF(3)
                                 }
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This variable indicates if there is an
            alarm present for the DS3 PLCP.  The value
            receivedFarEndAlarm means that the DS3 PLCP
            has received an incoming Yellow
            Signal, the value incomingLOF means that
            the DS3 PLCP has declared a loss of frame (LOF)
            failure condition, and the value noAlarm



Tesink                      Standards Track                    [Page 28]

RFC 2515                 ATM Management Objects            February 1999


            means that there are no alarms present.
            Transition from the failure to the no alarm state
            occurs when no defects (e.g., LOF) are received
            for more than 10 seconds."
          ::= { atmInterfaceDs3PlcpEntry 2}

     atmInterfaceDs3PlcpUASs  OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The counter associated with the number of
            Unavailable Seconds encountered by the PLCP."
          ::= { atmInterfaceDs3PlcpEntry 3}


     -- The ATM Interface TC Sublayer Table

     -- This table contains TC sublayer configuration and
     -- state parameters of those ATM interfaces
     -- which use TC sublayer for carrying ATM cells over
     -- SONET/SDH or DS3.


     atmInterfaceTCTable  OBJECT-TYPE
          SYNTAX         SEQUENCE OF AtmInterfaceTCEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This table contains ATM interface TC
            Sublayer parameters and state variables,
            one entry per ATM interface port."
          ::= { atmMIBObjects 4}

     atmInterfaceTCEntry OBJECT-TYPE
          SYNTAX         AtmInterfaceTCEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This list contains TC Sublayer parameters
            and state variables at the ATM interface and is
            indexed by the ifIndex value of the ATM interface."
          INDEX  {ifIndex }
          ::= { atmInterfaceTCTable 1}

     AtmInterfaceTCEntry    ::= SEQUENCE  {
          atmInterfaceOCDEvents      Counter32,
          atmInterfaceTCAlarmState   INTEGER



Tesink                      Standards Track                    [Page 29]

RFC 2515                 ATM Management Objects            February 1999


            }

     atmInterfaceOCDEvents  OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of times the Out of Cell
            Delineation (OCD) events occur.  If seven
            consecutive ATM cells have Header Error
            Control (HEC) violations, an OCD event occurs.
            A high number of OCD events may indicate a
            problem with the TC Sublayer."
          ::= { atmInterfaceTCEntry 